YY-2894 NEW SIEMENS SGT 400, YEAR 2018
YY-2894 NEW SIEMENS SGT 400, YEAR 2018
SIEMENS SGT 400 (12.9 MW) GAS TURBINE
· 11-STAGE COMPRESSOR, 6 COMBUSTION CHAMBERS, 2-STAGE POWER TURBINE
· GAS FUEL SYSTEM
· DLE COMBUSTION SYSTEM
· HOT-END DRIVE
· 2-SHAFT ENGINE
· LEFT-HAND EXHAUST
· MAIN LUBRICATION PUMP
· EQUIVALENT OPERATING HOURS : 0H
· TOTAL STARTS : 0
· NEW, NEVER INSTALLED OR COMMISSIONED
QUANTITY: 1
In stock
SKU
YY-2894
REFERENCE NUMBER: YY-2894
NEW SIEMENS SGT 400, YEAR 2018
DETAILS:
SIEMENS SGT 400 (12.9 MW) GAS TURBINE
· 11-STAGE COMPRESSOR, 6 COMBUSTION CHAMBERS, 2-STAGE POWER TURBINE
· GAS FUEL SYSTEM
· DLE COMBUSTION SYSTEM
· HOT-END DRIVE
· 2-SHAFT ENGINE
· LEFT-HAND EXHAUST
· MAIN LUBRICATION PUMP
· EQUIVALENT OPERATING HOURS : 0H
· TOTAL STARTS : 0
· NEW, NEVER INSTALLED OR COMMISSIONED
REDUCTION GEAR
· EPICYCLIC REDUCTION GEAR
· BASEPLATE MOUNTED
· HYDRAULIC START DRIVE
· MAIN DRIVE COUPLING
A.C. GENERATOR AND AVR
· 11.0 KV, ± 10%, 3 PHASE, 50 HZ, 1500 RPM
· CLASS F INSULATION AND CLASS B TOTAL TEMPERATURE RISES
· VOLTAGE TRANSFORMERS - CLASS 0.5, CURRENT TRANSFORMERS - CLASS 0.2 AND 5P10
· BASLER AVR
INTEGRAL LUBE OIL SYSTEM
· SUPPLIES GAS TURBINE, REDUCTION GEAR AND A.C. GENERATOR
· PRIMING AND MAIN OIL PUMPS
· A.C. AUXILIARY PUMP
· D.C. EMERGENCY PUMP
· LUBE OIL VENT OIL MIST ELIMINATOR
GAS FUEL SYSTEM
· DOUBLE BLOCK AND VENT VALVES AND RIGID PIPEWORK
· FUEL CONTROL VALVES (PILOT AND MAIN)
· EXTERNAL BLOCK AND VENT VALVES
ELECTRO-HYDRAULIC GAS TURBINE START SYSTEM
· 400V ELECTRIC MOTOR
· HYDRAULIC PUMP AND MOTOR
· CONTROL VALVES
DUAL MODE COMPRESSOR WASH SYSTEM
· TO ALLOW FOR “CRANKED” WASHING
· HIGH PRESSURE COMPRESSED AIR WASH MODULE
· CONTROL VALVES AND PIPEWORK
· QUICK-DISCONNECT CONNECTOR AT SKID EDGE
· MOBILE TANK
· LOW AMBIENT AIR TEMPERATURE PROTECTION
OUTDOOR ACOUSTIC ENCLOSURE 80DB(A)
· STANDARD COLOR RAL 7032
· ACCESS DOORS, APERTURES, GLAND PLATES
· INTERIOR LIGHTING AND INSPECTION OF WINDOWS
· REMOVABLE PANELS FOR ALTERNATOR REMOVAL
· TURBINE EXHAUST SHROUD
ENCLOSURE VENT SYSTEM 80DB(A)
· VENT SYSTEM FOR GAS TURBINE/REDUCTION GEAR
· 2-STAGE STATIC FILTERS (F5, F8)
· NEGATIVE PRESSURE ENCLOSURE
· ATEX EXTRACT FAN (ZONE 2)
· ATTENUATORS
· WEATHER PROTECTION
TURBINE AIR INTAKE SYSTEM 80DB(A)
· RAIN/SNOW INGRESS PROTECTION
· HEATED VANE SEPARATOR ANTI-ICING SYSTEM
· 3-STAGE STATIC FILTRATION :
1 ST STAGE PANEL FILTERS(F5)
2 ND STAGE PANEL FILTERS (F8)
3 RD STAGE PANEL FILTERS (H11)
· ATTENUATION, DUCTWORK AND COMPENSATOR
· SUPPORT STEELWORK
AIR INTAKE FILTER ACCESS PLATFORM
· LADDER
· HANDRAILS
· KICK PLATES
A.C. GENERATOR VENT SYSTEM 80DB(A)
· 2-STAGE STATIC FILTERS (F5, F8)
· ATTENUATION AND COMPENSATOR
OIL COOLER AIR BLAST SYSTEM 80DB(A)
· SINGLE AXIAL FLOW FAN
· COOLER MATRIX
· ATTENUATION
CONTROL CABIN
· HOUSES UNIT CONTROL PANEL SUITE AND CO2 EXTINGUISHING
· INTERIOR LIGHTING
· AIRCONDITIONED
EXHAUST SYSTEM
· SIDE EXIT
· PRIMARY COMPENSATOR
· THERMAL/ACOUSTIC SHROUD
· 75DB(A) SILENCER
FIRE PROTECTION AND GAS DETECTION SYSTEMS
· FOUR-ZONE FIRE MONITORING EQUIPMENT
· CO2 STORAGE AND CO2 DISCHARGE NOZZLES
· INFRA-RED (3) AND HEAT (RATE/RISE) DETECTORS(2)
· SHUT-OFF DAMPER AT VENTILATION SYSTEM DISCHARGE
· TWO-LEVEL GAS DETECTION
· EN54 / ISO 6183 COMPLIANT
ON-SKID CONTROL PANELS
COMPRISING OF THE FOLLOWING:
GAS TURBINE CONTROL AND PROTECTION SECTION
· ALLEN BRADLEY “CONTROLLOGIX” PLC
· DIGITAL ENGINE MANAGEMENT SYSTEM
· CONTROL, MONITORING AND PROTECTION (PRESSURES, TEMPERATURES, VIBRATION, ETC)
· REMOTE COMMUNICATION
· SYSTEM GRAPHICS
· ON-SKID HMI
· MODULAR DISTRIBUTED I/O
· DATA COMMUNICATION LINK (MODBUS PROTOCOL OVER TCP/IP)
MOTOR CONTROL CENTRE
· SINGLE 400V, 50HZ, 3PH CONNECTION
· A.C. POWER DISTRIBUTION FOR THE GENERATORSET
· MOTOR STARTERS AND PROTECTION
· DISTRIBUTION MCB'S FOR AUXILIARY A.C. SUPPLIES
· SKID-MOUNTED ALLOWING A SINGLE POINT OF CONTACT FOR THE CUSTOMER
BATTERY CHARGER AND UNINTERRUPTIBLE POWER SUPPLY
· BATTERY CHARGER AND UPS 24VDC SUPPLY TO CONTROL SYSTEMS
· TO POWER LUBE OIL PUMP FOR 3 HOURS AFTER LOSS OF A.C. SUPPLY
GENERATOR CONTROL AND PROTECTIONSECTION
· ELECTRONIC AUTOMATIC VOLTAGE REGULATOR
· DIGITAL INTEGRATED PROTECTION RELAY COMPRISING:
· DIFFERENTIAL FAULT (87G/T)
· STATOR EARTH FAULT (51N)
· OVERCURRENT (51)
· THREE-PHASE OVERVOLTAGE (59)
· THREE-PHASE UNDER VOLTAGE (27)
· REVERSE POWER (32)
· UNDER FREQUENCY (81U)
· OVER FREQUENCY (81O)
· LOSS OF EXCITATION (40)
· NEGATIVE PHASE SEQUENCE (46)
SYNCHRONIZING EQUIPMENT SECTION
· AUTO AND CHECK SYNCHRONIZERS
· SELECTOR SWITCHES, BUS VOLTMETER, AND SYNCHROSCOPE
· AUTOMATIC OR MANUAL FORWARD AND BACK SYNCHRONIZING
· MV CIRCUIT BREAKER CONTROL
QUANTITY: 1