Search results for: 'speed'
- Related search terms
- speed rpm relation
- speed run.com
- speed clutch cover fan
- speed hub 5.2.0
- SPEED ENGINEER CO.,LTD.
- A-1861 SANTEX PRE-TREATMENT AND WASHING MACHINE TYPE ACTIWASH YEAR 2002REFERENCE NUMBER: M-1861 (770235KOL6RX) SANTEX PRE-TREATMENT AND WASHING MACHINE TYPE ACTIWASH YEAR 2002 DESIGNED FOR LOW-TENSION PRE-TREATMENT OF WOVEN AND KNITTED GOODS MANUFACTURER: SANTEX - SWITZERLAND YEAR OF MANUFACTURE: 2002 WORKING WIDTH: 2200/1800 mm SPEED OF MACHINE: 3-100 M/MIN PRODUCTION SPEED: APPROX. 75 M/MIN THE DAILY OUTPUT WILL DEPEND E.G. ON QUALITY AND WEIGHT OF FABRICS/KNIT GOODS YOU WILL WASH ON THESE MACHINES. SO FAR THE PLANT WAS RUNNING AT AN AVERAGE SPEED OF 40 M/MIN, I.E. 2,400 MTRS PER WORKING HOUR. QUANTITY AVAILABLE: 1 Learn More
- T-6543 MEDICAL UNIVERSAL TENSILE TESTING EQUIPMENT
REFERENCE NUMBER: T-6543
MEDICAL UNIVERSAL TENSILE TESTING EQUIPMENT
SHANDONG INDEPENDENTLY RESEARCH AND DEVELOPMENT THIS COMPREHENSIVE TESTING MACHINE FOR SURGICAL MASK & PROTECTIVE CLOTHING, IT IS WIDELY USED IN A VARIETY OF MASK STRENGTH DETECTION PROJECTS.FEATURES:COMPLY WITH NATIONAL STANDARDS, MEDICAL STANDARDS TESTING REQUIREMENTS, AUTOMATIC SOFTWARE CONTROL SYSTEM, MEET THE REQUIREMENTS OF DATA STORAGE, PRINTING, COMPARISON. THE IMPORTED SERVO MOTOR IS EQUIPPED WITH PRECISION SCREW DRIVE SYSTEM TO ENSURE THE STABILITY OF TEST DATA.
TEST STANDARDS:
GB 19082-2009 TECHNICAL REQUIREMENTS FOR DISPOSABLE PROTECTIVE CLOTHING FOR MEDICAL USE (4.5 BREAKING STRENGTH -THE BREAKING STRENGTH OF MATERIALS IN KEY PARTS OF PROTECTIVE CLOTHING SHOULD NOT BE LESS THAN 45N)
(4.6 ELONGATION AT BREAK -THE ELONGATION AT BREAK OF KEY PARTS OF PROTECTIVE CLOTHING SHOULD NOT BE LESS THAN 15%)
SELF-PRIMING FILTER RESPIRATOR FOR RESPIRATORY PROTECTION ARTICLES5.6.2 BREATHING BONNET -BREATHING BONNET SHALL BE SUBJECT TO AXIAL TENSION"DISPOSABLE MASK: 10N FOR 10S" "REPLACEABLE MASK: 50N FOR 10S"
(5.9 HEADBAND -HEADBAND SHOULD BEAR THE TENSION "DISPOSABLE MASK: 10N, 10S" "REPLACEABLE HALF MASK: 50N FOR 10S" "FULL MASK: 150N FOR 10S")
5.10 JOINTS AND CONNECTING PARTS -JOINTS AND CONNECTING PARTS SHALL BE SUBJECT TO AXIAL TENSION
"REPLACEABLE HALF MASK: 50N FOR 10S" "FULL COVER 250N FOR 10S"
GB/T 32610-2016 TECHNICAL SPECIFICATION FOR DAILY PROTECTIVE MASKS
(6.9 BREAKING STRENGTH OF THE MASK BELT AND THE CONNECTION BETWEEN THE MASK BELT ANDTHE MASK BODY ≥ 20N)
(6.10 FASTNESS TO BREATHING BONNET: NO SLIPPAGE, BREAKAGE OR DEFORMATION SHALL OCCUR)
YY/T 0699-2013 DISPOSABLE SURGICAL MASK
(4.4 MASK BELT -THE BREAKING FORCE AT THE CONNECTION POINT BETWEEN EACH MASK BELT AND THE MASK BODY IS NOT LESS THAN 10N)
YY 0469-2011 SURGICAL MASK FOR MEDICAL USE (5.4.2 MASK BELT)
GB/T 3923.1-1997 DETERMINATION OF BREAKING STRENGTH AND ELONGATION AT BREAK OF FABRICS (STRIP METHOD)
DISPOSABLE RUBBER INSPECTION GLOVES (6.3 TENSILE PROPERTIES)
INSTRUMENT TECHNICAL PARAMETERS:
SPECIFICATION: 200N (STANDARD) 50N, 100N, 500N, 1000N (OPTIONAL)
ACCURACY: BETTER THAN 0.5RESOLUTION OF FORCE VALUE: 0.1N
DEFORMATION RESOLUTION: 0.001mm
TEST SPEED: 0.01mm/MIN ~ 2000mm/MIN (STEPLESS SPEED REGULATION)
WIDTH OF SAMPLE: 30mm (STANDARD FIXTURE) 50mm (OPTIONAL FIXTURE)
CLAMPING OF SAMPLES: MANUAL (PNEUMATIC CLAMPING CAN BE CHANGED)
STROKE: 700mm (STANDARD) 400mm, 1000mm (OPTIONAL)
QUANTITY: 1
Learn More - T-6544 SYNTHETIC BLOOD PENETRATION TESTER FOR SURGICAL MASK
REFERENCE NUMBER: T-6544
SYNTHETIC BLOOD PENETRATION TESTER FOR SURGICAL MASK
TECHNICAL INDICATORS:
1. THE PROTRUDING SAMPLE FIXING DEVICE CAN SIMULATE THE ACTUAL USE STATE OF THE MASK, SET ASIDE THE TEST TARGET AREA WITHOUT DESTROYING THE SAMPLE, AND DISTRIBUTE THE SYNTHETIC BLOOD IN THE TARGET AREA OF THE SAMPLE.
2. THE SPECIAL FIXED-PRESSURE INJECTION DEVICE CAN EJECT A CERTAIN VOLUME OF SYNTHETIC BLOOD IN A CONTROLLED TIME.
3. IT CAN FULLY SIMULATE THE INJECTION SPEED CORRESPONDING TO THE AVERAGE BLOOD PRESSURE OF HUMAN BODY OF 10.6KPA, 16KPA AND 21.3KPA.
4. A FIXED TARGET PLATE IS SET TO BLOCK THE HIGH-PRESSURE EDGE PART OF THE INJECTED LIQUID FLOW AND ONLY ALLOW THE STEADY FLOW PART TO BE SPRAYED ON THE SAMPLE, WHICH INCREASES THE ACCURACY AND REPEATABILITY OF THE LIQUID VELOCITY SPRAYED ON THE SAMPLE.
STANDARDS:
MEDICAL RESPIRATOR TECHNICAL REQUIREMENTS, 5.5 SYNTHETIC BLOOD PENETRATION BARRIER PERFORMANCE
YY/T 0691-2008 INFECTIOUS PATHOGEN PROTECTION EQUIPMENT MEDICAL MASK RESISTANCE TO SYNTHETIC BLOOD PENETRABILITY TEST METHOD (FIXED VOLUME, HORIZONTAL INJECTION)
YY 0469-2011 MEDICAL SURGICAL MASK TECHNOLOGY REQUIRES A BLOOD PENETRATION TEST DEVICE
ISO 22609:2004 INFECTIOUS PATHOGEN PROTECTION EQUIPMENT MEDICAL MASK TEST METHOD FOR RESISTANCE TO SYNTHETIC BLOOD PENETRATION (FIXED VOLUME, HORIZONTAL INJECTION)
ASTM F1862-07 STANDARD TEST METHOD FOR RESISTANCE OF MEDICAL FACE MASKS TO BLOT BY SYNTHETIC BLOOD (HORIZONTAL PROJECTION OF FIXED VOLUME AT A KNOW VELOCITY)
TECHNICAL PARAMETERS:
1. INJECTION DISTANCE: 300mm ~ 305mm ADJUSTABLE
2. NOZZLE DIAMETER: 0.84mm
3. INJECTION SPEED: 450CM/S, 550CM/S, 635CM/S
4. WEIGHT: 35KG
5. POWER SOURCE: AC220V 50HZ
QUANTITY: 1
Learn More - T-6549 CONSTANT TEMPERATURE AND HUMIDITY CHAMBER -FABRIC WATER VAPOR TRANSMISSION RATE
REFERENCE NUMBER: T-6549
CONSTANT TEMPERATURE AND HUMIDITY CHAMBER -FABRIC WATER VAPOR TRANSMISSION RATE
TESTING METER (WITH MOISTURE PERMEABLE CUP)
TECHNICAL DESCRIPTION OF THE INSTRUMENT:
IT IS MAINLY USED TO MEASURE THE MOISTURE PERMEABILITY OF ALL KINDS OF FABRICS, INCLUDING PERMEABLE COATED FABRICS. STRUCTURE PRINCIPLE: ADOPT COMPUTER CONTROL, CREATING A CONSTANT TEMPERATURE, AND HUMIDITY TEST ENVIRONMENT, TEST ENVIRONMENT IN THE CONSTANT TEMPERATURE, AND HUMIDITY, MOISTURE VAPOR TRANSMISSION CUP, PLACED 6 SAMPLE INTO THE GLASS AND THE RUBBER GASKET SEAL, THE CONTAINING HYGROSCOPIC AGENT OR WATER SEAL IS SPECIFIED BY THE WET CUP PLACED IN THE FABRIC SAMPLE TEMPERATURE AND HUMIDITY OF THE ENVIRONMENT, THE SEAL MOISTURE VAPOR TRANSMISSION CUP ACCORDING TO A CERTAIN TIME (INCLUDING SAMPLE AND HYGROSCOPIC AGENT OR WATER) TO CALCULATE THE MOISTURE TRANSMISSION QUALITY CHANGE.
TESTING STANDARD:
GB19082-2009 MEDICAL PRIMARY PROTECTIVE CLOTHING
TECHNICAL REQUIREMENTS GUIDELINES FOR THE SELECTION OF YY-T1498-2016 MEDICAL PROTECTIVE CLOTHING
GB/T12704.1 DETERMINATION OF MOISTURE PERMEABILITY OF FABRICS --HYGROSCOPIC METHOD
DETAILED TECHNICAL SPECIFICATIONS AND CONFIGURATION:
TECHNICAL INDICATORS:
1. TEMPERATURE CONTROL RANGE: -40°C ~ 150°C;RESOLUTION; 0.1 °C
2. HUMIDITY CONTROL RANGE: 50%RH ~ 95% RH±5%
3. SPEED RANGE: 2mm ~ 60mm/MIN
4. CONTROL PRECISION: TEMPERATURE <0.1°C; HUMIDITY + / -1% RH OR LESS
5. CYCLIC WIND SPEED: 0.02 ~ 0.5M/S, 0.3 ~ 0.5M/S
6. TIME CONTROL: 1 ~ 9999H
7. MOISTURE PERMEABLE AREA: 2827 mm 2 (DIAMETER IS 60 mm --NATIONAL STANDARD)
8. QUANTITY OF PERMEABLE CUPS: 6 GB;
9. DRYING BOX CONTROL TEMPERATURE: ROOM TEMPERATURE ~ 199 °C
10. TEST TIME: 1 ~ 999H
11. DRYING BOX STUDIO SIZE: 490 X 400 X 215mm
INSTRUMENT CONFIGURATION:
1. ONE MAIN MACHINE
QUANTITY: 1
Learn More - L-1736 FEMCO HORIZONTAL FOAM SAW MODEL 4A6 75” WIDE BLADE
REFERENCE NUMBER: L-1736
Learn More
MODEL 4A6
QUANTITY: 1 - R-1321 KUSTER CONTINUOUS OPEN WIDTH MERCERIZING, ROLLER SURFACE WIDTH 2000mm
R-1321 KUSTER CONTINUOUS OPEN WIDTH MERCERIZING, ROLLER SURFACE WIDTH 2000mm
DETAILS:
KUSTER CONTINUOUS OPEN WIDTH MERCERIZING
FOR THE PRETRATMENT OF WOVEN FABRICS
WIDTH OF FABRIC (WB): 960 TO 1800mm
ROLLER SURFACE WIDTH: 2000mm
DRIVE SIDE: LEFT SIDE
OPERATING SIDE: FAR SIDE
PRODUCTION SPEED: 60 M/MIN
TECHNICAL SPEED: 80 M/MIN
WATER PRESSURE: 2.0 + 0.5 BAR CONSTANT TO BE PROVIDED LOCALTY
VAPOUR PRESSURE: 3.0 + 0.5 BAR WET STEAM TO BE PROVIDED LOCALTY
AS PRESSURE (FREE OF OIL AND WATER): 7 BAR, TO BE PROVIDED LOCALTY
TYPE OF FABRICS: WOVEN FABRICS
QUALITY OF FABRICS: COTTON, BLENDS, VOISE (DRY)
FABRIC WEIGHT: 65 TO 300 G/M
HIGH-EFFICIENCY PADDER TYPE 222.50 LINE FORCB: 50 N/mm (50KP/CM)
HIGH-EFFICIENCY PADDER TYPE 824.27 LINE FORCE MAX: 50 N/mm
HIGH-EFFICIENCY PADDER TYPE 824.22 LINE FORCE MAX: 50 N/mm
MAANDER TYPE 834.43 FABRICS CONTENT: 15 m
SQUEEZER TYPE 225.65 LINE FORCB: 10 N/mm
MAANDER TYPE 834.43 FABRICS CONTENT: 15 m
SQUEEZER TYPE 225.65 LINE FORCB: 10 N/mm
STILL RUNNING IN MILLSQUANTITY: 1
Learn More - P-2212 RIETER OE R 20 SPINNING MACHINE YEAR 2002
P-2212 RIETER OE R 20 SPINNING MACHINE YEAR 2002
RIETER
TYPE: OE R 20
SPINNING MACHINE
YEAR: 2002
300 ROTORS
CYLINDRICAL PACKAGE 170mm HEIGHT x 320 mm DIAMETER
PACKAGE WEIGHT MAXIMUM 3.0 KILOGRAMS
ROTOR DIAMETER 28 OR 30 mm
OB 20 (UNIVERSAL)
COMBERS SPEED: 7000 to 9000 RPM
ROTORS SPEED: 90 to 10,000 RPM
MANUFACTURED YARNS: VISCOSE, VISCOSE/PES – TEX 20, 25, 30
WAXING DEVICE
AUTOMATIC DOFFING (2 PER MACHINE)
BLOWER
USTER QUANTUM
3 X 380 VOLTS, 50 HERTZ, 6 BARS
STILL IN OPERATIONQUANTITY: 1
Learn More - C-3729 RIETER OE R 20 WITH 300 ROTORS, YEAR 2002
C-3729 RIETER OE R 20 WITH 300 ROTORS, YEAR 2002
RIETER
MODEL: OE R 20
YEAR: 2002
300 ROTORS
CYLINDRICAL PACKAGE: 170mm HEIGHT X 320mm DIAMETER
PACKAGE WEIGHT MAXIMUM: 3.0 KGS
ROTOR DIAMETER: 28 OR 30mm
OB 20 (UNIVERSAL)
COMBERS SPEED: 7000 TO 9000 RPM
ROTORS SPEED: 90 TO 100 000 RPM
MANUFACTURED YARNS: VISCOSE
VISCOSE/PES - TEX 20, 25, 30
WAXING DEVICE
AUTOMATIC DOFFING (2 PER MACHINE)
BLOWER
USTER QUANTUM
3 X 380V
50 HZ
6 BARSQUANTITY: 1
Learn More - K-5601 KUSTERS CONTINOUS BLEACHING RANGE YEAR 2004 3400MM
REFERENCE NUMBER: K-5601
KUSTERS CONTINOUS BLEACHING RANGE YEAR 2004 3400MM
YOM: 2004
WIDTH: 3400mm
FACE WIDTH
WORKING WIDTH 3200mm
PRODUCTION SPEED 70 METER/MIN
TECHNICAL SPEED 100 METER/MIN
WATER PRESSURE 2.0-2.5 BAR
STEAM 2.0-2.5 BAR
REQUILTERED COMPRESSED AIR 7.0 BAR
FABRIC WEIGHT 70-250 GSM
QUANTITY: 1
Learn More