T-6552 MASK AIR TIGHTNESS TESTERREFERENCE NUMBER: T-6552
MASK AIR TIGHTNESS TESTER
MASK AIR TIGHTNESS TESTER
HOW TO CHOOSE A HIGH-QUALITY MASK NOT ONLY DEPENDS ON THE FILTERING EFFICIENCY OF THEMASK, BUT ALSO TO CONFIRM WHETHER THE MASK IS COMPLETELY IN CONTACT WITH THE FACE, OTHERWISE AEROSOL PARTICLES SUCH AS GERMS THAT HAVE NOT BEEN FILTERED BY THE MASK WILL BE INHALED FROM THE INADEQUATE ADHESION. THEREFORE, IT IS VERY IMPORTANT TO CHECK THE WEARING STATUS OF THE MASK. THE EUROPEAN AND AMERICAN COUNTRIES HAVE LISTED THE APPLICATION TEST OF THE MASK AS A STRONG INSPECTION ITEM.
FOR EXAMPLE, THE N95 MASK IS ONE OF 9 TYPES OF PARTICULATE PROTECTIVE MASKS CERTIFIED BY NIOSH (NATIONAL INSTITUTE OF OCCUPATIONAL SAFETY AND HEALTH). "N" INDICATES OIL RESISTANCE."95" INDICATES THAT THE PARTICLE CONCENTRATION IN THE MASK IS MORE THAN 95% LOWER THAN THAT OF THE PARTICLES OUTSIDE THE MASK WHEN EXPOSED TO THE SPECIFIED NUMBER OF SPECIAL TEST PARTICLES. N95 IS NOT A SPECIFIC PRODUCT NAME, AS LONG AS IT MEETS THE N95 STANDARD AND PASSES THE NIOSH REVIEW, IT CAN BE CALLED "N95 MASK".
N95 TYPE MASKS, IN ADDITION TO THE FILTERING EFFICIENCY OF THE MASKS, THE CLOSENESS OF THE MASKS TO THE FACE IS ONE OF THE IMPORTANT FACTORS THAT DETERMINE THE EFFECTIVENESS OF THE USE OF THE MASKS. THE SUITABILITY OF DIFFERENT TYPES OF MASKS FOR THE HUMAN FACE VARIES GREATLY.
THEREFORE, BEFORE USING A MASK, THE SUITABILITY OF THE MASK SHOULD BE CHECKED FIRST. DURING THETIGHTNESS TEST OF THE WEARER'S FACE, ENSURE THAT AIR CAN PASS IN AND OUT THROUGH THE MASK WHEN IT IS CLOSE TO THE EDGE OF THE FACE. THE MASK TIGHTNESS TESTER CAN QUICKLY COMPLETE THE TIGHTNESS TEST OF RESPIRATORS SUCH AS MASKS TO ENSURE THAT IT PROVIDES GOOD PROTECTION PERFORMANCE. IT CONFORMS TO THE CHINESE RESPIRATOR STANDARD GB2626-2019 STANDARD, OSHA / CSA STANDARD AND CHINA GENERAL ADMINISTRATION OF QUALITY SUPERVISION, INSPECTION AND QUARANTINE "GB 19083-2010 TECHNICAL REQUIREMENTS FOR MEDICAL PROTECTIVE MASKS" JOINTLY ISSUED BY THE CHINA NATIONAL STANDARDIZATION ADMINISTRATION COMMITTEE.
ADHESION (SUITABILITY TEST): THE MASK DESIGN SHOULD PROVIDE GOOD ADHESION. THE OVERALL FIT FACTOR OF THE MASK SHOULD NOT BE LESS THAN 100. THIS TEST THE REQUIREMENTS WERE FORMALLY IMPLEMENTED ON AUGUST 1, 2011.
Learn MoreMASK TIGHTNESS TESTER USES CNC TECHNOLOGY, SUITABLE FOR 100 / 99 / P3 / HEPASERIES MASKS DISPOSABLE FILTER MASK TIGHTNESS TEST (INCLUDING DISPOSABLE DUST MASKS SUCH ASN95 / N90 / KN95), GAS MASKS / BREATHING MASKS, ADHESIVENESS TEST OF HALF-MASK AND FULL FACE MASK, INDEPENDENT OR COMPUTER CONTROL, FIVE LANGUAGES SWITCH DISPLAY, EQUIPPED WITH MULTIPLE COMMUNICATION INTERFACES (USB, ETHERNET), WIFI CAN ALSO BE ENABLED, ONE COMPUTERCAN CONTROL FOUR INSTRUMENTS AT THE SAME TIME.PARAMETER:CONCENTRATION RANGE: 0 ~ 100,000 / CM3GRAIN DIAMETER: 0.02 ~ 1.0^MFLOW: SAMPLING FLOW: 100CM3 / MINTOTAL FLOW: 700CM3 / MINCLOSENESS COEFFICIENT TEST: DIRECT TEST (COUT/ CIN)LIQUOR: 99.5% + ISOPROPANOL (ANALYTICAL GRADE)DISPLAY: 7INCH TRUE COLOR TOUCH SCREENCOMMUNICATION INTERFACE: USB X 3 (HOST X 2,DEVICE X 1) ETHERNET INTERFACE X1CONNECTION PORT: ENVIRONMENT PORT, SAMPLING PORTWIFI: EQUIPPEDLANGUAGES: ENGLISH, FRENCH, SPANISH, PORTUGUESE, CHINESEFLOW CONTROL: SENSOR CONTROLPC CONTROLLABLE OPERATION: ONE COMPUTER CAN CONTROL 4 INSTRUMENTS AT THE SAME TIMEDATA OUTPUT FORMAT: MICROSOFT EXCELWORKING TEMPERATURE: 15 ~ 35 °CPOWER SOURCE: AC 110 —240V 50 / 60HZAPPEARANCE SIZE: 208 X 117 X 262MMWEIGHT: 2.1KGACCESSORIES: ALCOHOL REAGENT BOTTLE, PROTECTIVE CAP, REAGENT STICK, ZERO-COUNT FILTER, STRAINER, SAMPLING TUBE, INSTRUCTION MANUAL, AC ADAPTER, TOUCH SCREEN PEN, OPTIONAL COMPUTER.OPTIONAL: TEST KIT FOR TIGHTNESS COEFFICIENTIN ORDER TO PREVENT INFECTION AT THE MEDICAL SITE AND DURING LABOR WORK, WORKERS MUST BE PROTECTED FROM INHALABLE HAZARDOUS SUBSTANCES IN THE WORKPLACE, AND RESPIRATORS SUCH AS MASKS MUST BE WORN DURING WORK.SELECT A RESPIRATOR, SUCH AS A MASK, BASED ON YOUR FACIAL FEATURES, AND EVALUATE THE TIGHTNESS BETWEEN THE RESPIRATOR, SUCH AS A MASK AND THE FACE, TO CHECK WHETHER THERE ARE GAPS OR LEAKS THAT PUT WORKERS AT RISK. THE MASK TIGHTNESS TESTER CAN QUICKLY COMPLETE THE TIGHTNESS TEST OF RESPIRATORS SUCH AS MASKS TO ENSURE THAT IT PROVIDES GOOD PROTECTIVE PERFORMANCE. SECURITY EXPERTS WILL ALSO DEVELOP PROTECTION SCHEMES AND STANDARD REGULATIONS BASED ON THE RESULTS OF THE TIGHTNESS TEST. WIDELY USED IN HOSPITALS, MANUFACTURING PLANTS, PRODUCTION SITES, FIREFIGHTING WORKPLACES AND OTHER OFFICIAL TESTING AGENCIES.MASK TIGHTNESS TESTER FEATURES:• QUANTITATIVE TIGHTNESS TEST FOR RESPIRATORS SUCH AS MASKS (QNFT)• APPLICABLE TO 100/99 / P3 / HEPA SERIES MASK DISPOSABLE FILTER MASK TIGHTNESS TEST (INCLUDING N95 / N90 / KN95 AND OTHER DISPOSABLE DUST MASKS)• ADHESION TEST OF HALF MASK AND FULL FACE MASK• GAS MASK TIGHTNESS TEST• PAPR MASK TIGHTNESS TEST• SCBA RESPIRATOR MASK TIGHTNESS TEST• 7INCH TRUE COLOR TOUCH SCREEN• INDEPENDENT OR COMPUTER CONTROLLED• USING CNC TECHNOLOGY• ENGLISH, FRENCH, SPANISH, PORTUGUESE, CHINESE LANGUAGE SWITCHING DISPLAY• COMPLIES WITH US OSHA STANDARDS, CANADIAN STANDARDS ASSOCIATION (CSA) GUIDELINES, INCLUDING N95• EQUIPPED WITH A VARIETY OF COMMUNICATION INTERFACES (USB, ETHERNET), AND CAN ALSO ENABLE WIFI• ONE COMPUTER CAN CONTROL FOUR INSTRUMENTS AT THE SAME TIMEQUANTITY: 1 -
T-6568 DISPOSABLE ISOLATION GOWNDISPOSABLE ISOLATION GOWN
Learn More
IT'S MAINLY USED IN PLACES AS FOLLOW;
1) GOVERNMENT/COMMUNITY/BUS STATION/TRAIN STATION/ AIRPORT/SEAPORT/ OTHER PUBLIC EPIDEMIC PREVENTION WORKERS;
2) FOOD FACTORY;
3) PHARMACY;
4) FOOD SUPERMARKET;
CERTIFICATE: CE
ITEM 001
QUANTITY: 3,000PCS-9,999 PCS
ITEM 002
QUANTITY: 10,000PCS-99,999PCS
ITEM 003
QUANTITY: ≥100,000PCS -
T-6567 MEDICAL NON-STERILE PROTECTION SUITMEDICAL NON-STERILE PROTECTION SUIT
Learn More
IT'S MAINLY USED IN PLACES AS FOLLOW;
1) HOSPITAL OUTSIDE ICU
2) GOVERNMENT/COMMUNITY/BUS STATION/TRAIN STATION/ AIRPORT/SEAPORT/ OTHER PUBLIC EPIDEMIC PREVENTION WORKERS;
3) FOOD FACTORY;
4) PHARMACY;
5) FOOD SUPERMARKET;
ITEM 001
QUANTITY: 1,000PCS-9,999 PCS
ITEM 002
QUANTITY: 10,000PCS-99,999PCS
ITEM 003
QUANTITY: ≥100,000PCS -
J-2786 VERTICAL MODULE FOR TEMPERATURE MEASUREMENT & FACE RECOGNITIONUSES ROCKCHIP RK3288 / RK 3399 / QUALCOMM MSM8953 HIGH-PERFORMANCE HARDWARE PLATFORM, EQUIPPED WITH INDUSTRIAL GRADE BINOCULAR CAMERA, LIVE FACIAL RECOGNITION SOFTWARE AND INFRARED THERMAL IMAGING MODULE TO SUPPORT FACE-WITH-MASK INDEITIFICATION.
SUPPORTS EXPANSION OF VARIOUS PERIPHERALS SUCH AS ID CARD READERS, FINGERPRINT READERS, ETC WHICH CAN BE APPLIED TO GATE PASSAGES AND ATTENDANCE SYSTEM TO ACHIEVE SAFE AND EFFICIENT ACCESS CONTROL FOR PERSONNEL
CAN BE USED WITH ACCESS GATES & ATTENDANCE FOR COMMUNITIES, OFFICES, SCHOOLS, HOTELS, PUBLIC VENUES, TRANSPORTATION HUBS AND PUBLIC SERVICE PLACES
FEATURES:
8 INCH IPS FULL-VIEW LCD DISPLAY
INDUSTRIAL APPEARANCE, WATERPROOF AND SUNPROOF DESIGN
STABLE AND RELIABLE
SUPPORTS A DATABASE OF 30,000 FACES
THE 1:1 COMPARISON RECOGNITION RATE IS MORE THAN 99.7%
THE 1:N COMPARISON RECOGNITION RATE IS MORE THAN 96.7% @ 0.1% MISRECOGNITION RATE
LIVE DETECTION ACCURACY RATE: 98.3% @ 1% MISRECOGNITION RATE
FACE RECOGNITION PASS SPEED IS LESS THAN 1 SECOND
SUPPORTS ACCURATE FACE RECOGNITION AND COMPARISON WHILE WEARING A MASK
USES INDUSTRIAL GRADE BINOCULAR WIDE DYNAMIC CAMERA, NIGHT INFRARED AND LED DUAL PHOTO FLOOD LAMP
ROCKCHIP RK3288 QUAD-CORE PROCESSOR, ROCKCHIP RK3399 SIX-CORE PROCESSOR, AND QUALCOMM MSM8953 OCTA-CORE PROCESSOR
SUPPORTS HUMAN BODY TEMPERATURE DETECTION AND DISPLAY (BEST TEMPERATURE DETECTION DISTANCE IS 0.5 METERS, MAXIMUM IS 1 METER), MEASUREMENT ERROR +/- 0.5 °C
TEMPERATURE CAN BE READ IN ONLY A FEW SECONDS AND THE DEVICE AUTOMATICALLY SOUNDS AN ALARM FOR ABNORMALITIES
ATTENDANCE TEMPERATURE MEASUREMENT DATA EXPORTED IN REAL TIME
VARIOUS PERIPHERALS AVAILABLE FOR ID CARD READING, FINGERPRINT READING, IC CARD READING, 2-DIMENSIONAL CODE READING, ETC.
WITH COMPLETE DOCUMENTATION AND SUPPORT FOR SECONDARY DEVELOPMENT
SUPPORTS SYSTEM LEVEL, APP OFFLINE LEVEL, APP AND BACKGROUND NETWORK LEVEL MULTIPLE API DOCKINGCAMERA
RESOLUTION 2 MILLION PIXELS
TYPE BINOCULAR WIDE DYNAMIC CAMERA
APERTURE F2.4
FOCUSING DISTANCE 50-150CM
WHITE BALANCE AUTO
PHOTO FLOOD LIGHT LED AND IR DUAL PHOTO FLOOD LIGHTSCREEN
SIZE 8.0 INCH IPS LCD SCREEN
RESOLUTION 800×1280
TOUCH NOT SUPPORTED (OPTIONAL SUPPORT)PROCESSOR
CPU RK3288 QUAD-CORE (OPTIONAL RK3399 SIX-CORE, MSM8953
EIGHT-CORE)
STORAGE EMMC 8GINTERFACE
NETWORK MODULE ETHERNET AND WIRELESS (WIFI)
AUDIO 2.5W / 4R SPEAKERS
USB 1 USB OTG, 1 USB HOST STANDARD A PORT
SERIAL COMMUNICATION 1 RS232 SERIAL PORT
RELAY OUTPUT 1 DOOR OPEN SIGNAL OUTPUT
WIEGAND ONE WIEGAND 26/34 OUTPUT, ONE WIEGAND 26/34 INPUT
UPGRADE BUTTON SUPPORT UBOOT UPGRADE BUTTON
WIRED NETWORK 1 RJ45 ETHERNET SOCKETFUNCTION
CREDIT CARD READER NONE (OPTIONAL IC CARD READER, ID CARD, ID CARD)
FACE DETECTION SUPPORTS DETECTION AND TRACKING OF MULTIPLE PEOPLE AT THE SAME
TIME
FACE LIBRARY UP TO 30,000
1: N FACE RECOGNITION SUPPORT
1: 1 FACE COMPARISON SUPPORT
STRANGER DETECTION SUPPORT
IDENTIFY DISTANCE
CONFIGURATION
SUPPORT
UI INTERFACE CONFIGURATION SUPPORT
UPGRADE REMOTELY SUPPORT
INTERFACE INTERFACES INCLUDE DEVICE MANAGEMENT, PERSONNEL / PHOTO
MANAGEMENT, RECORD QUERY, ETC.
DEPLOYMENT METHOD SUPPORT PUBLIC CLOUD DEPLOYMENT, PRIVATIZED DEPLOYMENT, LAN
USE, STAND-ALONE USEINFRARED THERMAL IMAGING MODULE
TEMPERATURE DETECTION SUPPORT
TEMPERATURE DETECTION 1 METER (OPTIMAL DISTANCE 0.5 METER)
DISTANCE
TEMPERATURE
MEASUREMENT ACCURACY
≤ ±0.5℃
TEMPERATURE
MEASUREMENT RANGE
10℃~42℃
THERMAL FIELD OF VIEW 32 X 32℃
VISITORS' TEMPERATURE IS
NORMAL AND RELEASED
DIRECTLY
SUPPORT
ABNORMAL TEMPERATURE
ALARM
SUPPORT (TEMPERATURE ALARM VALUE CAN BE SET)GENERAL PARAMETERS
POWER DC12V(±10%)
OPERATING TEMPERATURE 0℃~60℃
STORAGE TEMPERATURE -20℃~60℃
POWER CONSUMPTION 13.5W(MAX)
INSTALLATION METHOD GATE BRACKET INSTALLATION
SIZE : STANDARD:274.24*128*21.48(MM); IC CARD / ID CARD:296.18*132.88*25(MM)PACKING LIST
Learn More
MACHINE * 1, POWER ADAPTER * 1, MANUAL * 1, CERTIFICATE OF CONFORMITY * 1 -
J-2792 MEDICAL FACE MASK SYNTHETIC BLOOD PENETRATION TESTERUSED FOR MEASURING THE RESISTANCE OF MEDICAL FACE MASKS TO PENETRATION BY A SPLASH OF SYNTHETIC BLOOD
BLOOD SPRAYING DISTANCE: 300 TO 310mm (APPROXIMATE, ADJUSTABLE)
NEEDLE INNER DIAMETER: 0.84mm
SPRAY SPEED: 4500mm PER SECOND, 5500mm PER SECOND, 6350mm PER SECOND
SIMULATED SYNTHETIC BLOOD PRESSURE: 10.6kPa, 16.0 kPa, 21.3 kPa, (i.e. 80mmHg, 120mmHg, 160mmHg)
SUPPORTS THE SPECIMEN MEDICAL FACE MASK ON THE TESTER’S CLAMPING DEVICE AND SPRAYS A FIXED VOLUME (~2ml) OF SYNTHETIC BLOOD SPLASHED HORIZONTALLY TO HIT THE MASK
TESTER CAN PROVIDE DIFFERENT BLOOD PRESSURES WITH PRECISION CONTROL VALVE TO GENERATE 2ml SYNTHETIC BLOOD WITH SURFACE TENSION OF 0.042 ± 0.002 N/m, WHICH MEETS THE REQUIREMENTS DEFINED IN STANDARDS BELOW:
ISO 22609
ASTM F1862
YY 0469-2011
GB/T 19083-2010LEAD TIME: 5 TO 7 WEEKS FROM RECEIPT OF ORDER
QUANTITY: 1
Learn More -
L-4753 COMPLETE ZIMMER CHROMOJET LINE, WIDTH 4000mm, YEAR 2000COMPLETE ZIMMER CHROMOJET LINE, WIDTH 4000mm, YEAR 2000
WIDTH: 4000mm
YEAR: 2000
DPI: 1.666mm = 16 DOTS PER INCH (DPI)
2560 JETS
EACH PUMP WITH 256 JETS (10 PUMPS TOTAL)
JETS ARE IN GOOD CONDITION, TO PRINT ALL KINDS OF CARPETS OF ANY WEIGHT OR PILE HEIGHT
CAN PRINT DOT OR HALF DOT
10 COLORS
COULD BE USED ALSO FOR BLANKETS
Learn More -
M-5819 USTER HVI-900 TESTER YEAR 1994M-5819 USTER HVI-900 TESTER YEAR 1994
MAKE: USTER
MODEL: HVI
YEAR: 1994 (APPROXIMATELY)
USTER HVI900 SUITABLE FOR MEASUREMENT OF RAW COTTON FIBER
SEMI AUTOMATIC SAMPLE TESTING
LENGTH & STRENGTH: LENGTH MODULE USED FOR MEASUREMENT OF LENGTH PARAMETERS SUCH AS UHML, ML, UNIFORMITY & SFI ETC. AND STRENGTH MODULE FOR BUNDLE STRENGTH IN GRAM/TEX AND ELONGATION IN %
MIX MODULE: MEASUREMENT OF MICRONAIRE
COLOR MODULE: COLOR MODULE MEASURES REFLECTANCE (RD) AND BRIGHTNESS (+B) AND COLOR GRADE FOR COTTON CLASSING
DOS OPERATING PLATFORM WITH DISPLAY & PRINTER
SYSTEM WAS CALIBRATED AND CHECKED USING USDA CALIBRATION SAMPLESQUANTITY: 1
Learn More -
R-1728 MARIO CROSTA SHEARING MACHINE, WIDTH 3600mm, YEAR 2007R-1728 MARIO CROSTA SHEARING MACHINE, WIDTH 3600mm, YEAR 2007
MARIO CROSTA SHEARING MACHINE
YEAR: 2007
FOR TERRY TOWEL
WIDTH: 3600mm
700.000 METER WORKED
WITH SPARE BLADE (NOT USED IN BOX)
WITH DUST SUCTION SYSTEM
RUNNING CONDITIONQUANTITY: 1
Learn More -
K-8416 G1 TONELLO 330 "CENTRIFUGING" INDUSTRIAL WASHING MACHINE-USEDREFERENCE NUMBER: K-8416
G1 TONELLO 330 "CENTRIFUGING" INDUSTRIAL WASHING MACHINE-USED
G1 TONELLO 330
“CENTRIFUGING” INDUSTRIAL WASHING MACHINE
FRONTAL TYPE
FOR CHEMICAL “STONE WASH”
CAPACITY LIT. 3.300
MOD. TONELLO G1 330
GENERAL DESCRIPTION:
TONELLO G1 IS A MACHINE WITH HIGH-SPEED HYDRO-EXTRACTION (600 R.P.M.) AND IT IS EQUIPPED WITH AUTOMATIC SELF-BALANCING SYSTEM
TONELLO G1 IS SUPPLIED WITH “SETTABLE INVERTER”
ROTATION SPEED FROM 0 TO 55 R.P.M
ALSO SETTING THE CENTRIFUGING SPEED FROM 0 TO 600 R.P.M.
WITH TIME OF CENTRIFUGE PROGRAMMABLE BY INDUSTRIAL PC
THE ACCESS MAIN DOOR TO THE DRUM IS VERY WIDE, IN ORDER TO EASY GARMENTS LOADING AND UNLOADING OPERATION
OPENING AND CLOSING ARE PNEUMATIC
DOUBLE TILTING SYSTEM FOR GARMENTS LOADING AND UNLOADING
DRIVING SYSTEM IS SITUATED ON THE UPPER PART OF THE MACHINE
WITH PROPER MATERIAL AND MOTORS SUITABLE TO WORK AT LOW AND HIGH R.P.M.
1 TANK FOR THE PREPARATION OF AUXILIARY PRODUCTS WITH CAPACITY OF LITTERS 180 EQUIPPED WITH ELECTRO-PUMP AND PNEUMATIC VALVES FOR THE SENT ONE
THE DRAINAGE IN DRAIN AND AUTOMATIC RINSES N° 2 WATER INLETS COMPLETE WITH PNEUMATIC VALVE- MECHANICAL WATER-COUNTER DIRECT HEATING AND COOLING SYSTEM
AUTOMATION WITH MICROPROCESSOR
TECHNICAL DATA TONELLO G1 330
DRUM DIMESION
-DRUM HOLING SHEET mm 4
THICKNESS
-DIAMETER MM 1900
-DEPTH MM 1150
-VOLUME LT. 3300
-DOOR DIAMETER MM 1020
-MAXIMUM LOADING KG. 120/130
CAPACITY
BASKET SPIN SPEED RPM 0-600
DIRECT STEAM CONNECTION Ø 1" 1/4
WATER INLET CONNECTION Ø 2 x 2
COMPRESSED AIR INLET Ø 1/4"
CONNECTION
STEAM IN MAXIMUM PRESSUREBAR BAR 6
WATER IN MAXIMUM PRESSURE BAR 4
COMPRESSED AIR IN MAXIMUM BAR 8
PRESSURE
POWER INSTALLED KW 22
3-PHASE VOLTAGE VOLT/HZ 400/50
PRODUCTS TANK Ø 240 H 400 LT. 80
TANK RINSING VALVE Ø 1/2"
MACHINE SIZE
-WIDTH MM 2500
-WIDTH WITH ELECTRICAL PANEL MM 2980
-DEPTH MM 2710
-HEIGHT MM 3000
Learn More