Search results for: 'used'
- Related search terms
- used foam cu
- Used Gas T
- Used Gas Tur
- Used Gas Turbine Generator
- used woo
-
T-6582 MEDICAL PROTECTIVE SUIT IMPERMEABLE STERILIZED (USED IN INFECTIOUS ISOLATION WARD)REFERENCE NUMBER: T-6582
MEDICAL PROTECTIVE SUIT IMPERMEABLE STERILIZED (USED IN INFECTIOUS ISOLATION WARD)
MEDICAL PROTECTIVE SUIT IMPERMEABLE STERILIZED (USED IN INFECTIOUS ISOLATION WARD)
1.NP3030: MEDICAL DISPOSABLE PROTECTIVE CLOTHING,STRONG RESISTANT
2.FABRIC: SF 66 G, COLOR: WHITE RUBBER:CAP/FOOT/CUFF/WAIST FRONT FLAP: DOUBLE-SIDED TAPE, TAPE:BLUE TAPE, ETHYLENE OXIDE DISINFECTION, STERILE
3.PACKAGED: 1PC/BAG, 32PCS/CARTON,10KG/CARTONCARTON SIZE: 470 X300 X420mm/CTN
4.NOTE: CLASS II MEDICAL TREATMENT, SCOPE OF USE: MEDICALPERSONNEL CONTACT WITH POTENTIALLY INFECTIOUS PATIENTSBLOOD, BODY FLUIDS, SECRETIONS, PARTICLES IN THE AIR TOPROVIDE BARRIER, PROTECTION. THIS PRODUCT IS USED FORISOLATION OF OBSERVATION WARD (ROOM), ISOLATION WARD(ROOM), ETC. IT IS STRICTLY PROHIBITED TO USE IN THE ISOLATIONCRITICAL CARE WARD (ROOM) AND OTHER PLACES WITH STRICTCONTROL OF MICROBIAL INDICATORS1PC/BAG, 32PCS/CARTON.
WEIGHT AND DIMENSIONS OF CARTONS: 10KG/CARTON
CARTONS IN A 20 FOOT CONTAINER: 370 BOXESSTERILIZED BY ETHYLENE OXIDE GAS
EACH PIECE IS INDIVIDUALLY VACUUM PACKED
1PER PLASTIC POUCH
QUANTITY: 10,000
Learn More -
M-5238 HFO POWER PLANTS (6MW EACH, TOTAL 24MW) YEAR 2008 – NEW (NEVER USED)REFERENCE NUMBER: M-5238 (1313AJWNXX12U) L HFO POWER PLANTS (6MW EACH, TOTAL 24MW) YEAR 2008 – NEW (NEVER USED) HFO POWER PLANTS 6MW EACH TOTALLING 24MW YEAR 2008 WITH 50HZ NEW (NEVER USED) QUANTITY AVAILABLE: 4 Learn More -
K-8416 G1 TONELLO 330 "CENTRIFUGING" INDUSTRIAL WASHING MACHINE-USEDREFERENCE NUMBER: K-8416
G1 TONELLO 330 "CENTRIFUGING" INDUSTRIAL WASHING MACHINE-USED
G1 TONELLO 330
“CENTRIFUGING” INDUSTRIAL WASHING MACHINE
FRONTAL TYPE
FOR CHEMICAL “STONE WASH”
CAPACITY LIT. 3.300
MOD. TONELLO G1 330
GENERAL DESCRIPTION:
TONELLO G1 IS A MACHINE WITH HIGH-SPEED HYDRO-EXTRACTION (600 R.P.M.) AND IT IS EQUIPPED WITH AUTOMATIC SELF-BALANCING SYSTEM
TONELLO G1 IS SUPPLIED WITH “SETTABLE INVERTER”
ROTATION SPEED FROM 0 TO 55 R.P.M
ALSO SETTING THE CENTRIFUGING SPEED FROM 0 TO 600 R.P.M.
WITH TIME OF CENTRIFUGE PROGRAMMABLE BY INDUSTRIAL PC
THE ACCESS MAIN DOOR TO THE DRUM IS VERY WIDE, IN ORDER TO EASY GARMENTS LOADING AND UNLOADING OPERATION
OPENING AND CLOSING ARE PNEUMATIC
DOUBLE TILTING SYSTEM FOR GARMENTS LOADING AND UNLOADING
DRIVING SYSTEM IS SITUATED ON THE UPPER PART OF THE MACHINE
WITH PROPER MATERIAL AND MOTORS SUITABLE TO WORK AT LOW AND HIGH R.P.M.
1 TANK FOR THE PREPARATION OF AUXILIARY PRODUCTS WITH CAPACITY OF LITTERS 180 EQUIPPED WITH ELECTRO-PUMP AND PNEUMATIC VALVES FOR THE SENT ONE
THE DRAINAGE IN DRAIN AND AUTOMATIC RINSES N° 2 WATER INLETS COMPLETE WITH PNEUMATIC VALVE- MECHANICAL WATER-COUNTER DIRECT HEATING AND COOLING SYSTEM
AUTOMATION WITH MICROPROCESSOR
TECHNICAL DATA TONELLO G1 330
DRUM DIMESION
-DRUM HOLING SHEET mm 4
THICKNESS
-DIAMETER MM 1900
-DEPTH MM 1150
-VOLUME LT. 3300
-DOOR DIAMETER MM 1020
-MAXIMUM LOADING KG. 120/130
CAPACITY
BASKET SPIN SPEED RPM 0-600
DIRECT STEAM CONNECTION Ø 1" 1/4
WATER INLET CONNECTION Ø 2 x 2
COMPRESSED AIR INLET Ø 1/4"
CONNECTION
STEAM IN MAXIMUM PRESSUREBAR BAR 6
WATER IN MAXIMUM PRESSURE BAR 4
COMPRESSED AIR IN MAXIMUM BAR 8
PRESSURE
POWER INSTALLED KW 22
3-PHASE VOLTAGE VOLT/HZ 400/50
PRODUCTS TANK Ø 240 H 400 LT. 80
TANK RINSING VALVE Ø 1/2"
MACHINE SIZE
-WIDTH MM 2500
-WIDTH WITH ELECTRICAL PANEL MM 2980
-DEPTH MM 2710
-HEIGHT MM 3000
Learn More -
K-5264 BARMAG CRAFT WINDER MODEL CW6 YEAR 1995REFERENCE NUMBER: K-5264 BARMAG CRAFT WINDER MODEL CW6 YEAR 1995 BARMAG WINDER MODEL CW6 WIDTH OF CHUCK: 980mm YEAR 1992 NUMBER OF ENDS: 6 AUTOMATIC TURRET CHARGE BOBBIN WEIGHT: 10 KG MAXIMUM QUANTITY AVAILABLE: 24 Learn More -
T-6586 ISOLATION PROTECTIVE CLOTHING MT-B001-XL, 70G COMPOSITE NON-WOVEN FABRICREFERENCE NUMBER: T-6586
ISOLATION PROTECTIVE CLOTHING MT-B001-XL, 70G COMPOSITE NON-WOVEN FABRIC
ISOLATION PROTECTIVE CLOTHING
MODEL: MT-B001-XL
MATERIAL: 70G COMPOSITE NON-WOVEN FABRIC
SURFACE: WITH BLUE SEALING STRIPS
WEIGHT: 230G/PIECE
SIZE: XL (170-180CM)
DESIGN: ONE-PIECE TYPE FRONT OPENING, COLLARLESS HOOD, ELASTIC BRIM, ELASTIC CUFFS AND LEG OPENINGS.
FEATURE: ISOLATE BACTERIA, WATERPROOF, MICRO BREATHABLE, TEXTURE SOFT, THE HIGHEST GRADE MEDICAL PROTECTIVE CLOTHING MATERIAL.
USAGE: USED FOR VIRUS PROTECTION IN HOSPITAL GENERAL SICKROOM, AIRPORT, BUS STATION, RAILWAY STATION, FACTORY ETC.
CERTIFICATE: CE
ITEM 001
QUANTITY: ≥ 30,000 PIECES
ITEM 002
QUANTITY: ≥ 10,000 PIECES
ITEM 003
QUANTITY: ≥ 1,000 PIECES
MARKS: THIS PROTECTIVE CLOTHING/ISOLATION CLOTHING NOT INCLUDED SHOES COVER, NOT USED IN ICU.
Learn More -
T-6585 ISOLATION PROTECTIVE CLOTHING MT-C001-XL, 70G COMPOSITE NON-WOVEN FABRICREFERENCE NUMBER: T-6585
ISOLATION PROTECTIVE CLOTHING MT-C001-XL, 70G COMPOSITE NON-WOVEN FABRIC
ISOLATION PROTECTIVE CLOTHING
MODEL: MT-C001-XL
MATERIAL: 70G COMPOSITE NON-WOVEN FABRIC
SURFACE: WITHOUT SEALING STRIPS
WEIGHT: 230G/PIECESIZE: XL(170-180CM)
DESIGN: ONE-PIECE TYPE
FRONT OPENING,COLLARLESS HOOD,ELASTIC BRIM,ELASTIC CUFFS AND LEG OPENINGS.
FEATURE: ISOLATE BACTERIA,WATERPROOF,MICRO BREATHABLE,TEXTURE SOFT,THE HIGHEST GRADE MEDICAL PROTECTIVE CLOTHING MATERIAL.
USAGE: USED FOR VIRUS PROTECTION IN HOSPITAL GENERAL SICKROOM,AIRPORT,BUS STATION,RAILWAY STATION,FACTORY ETC.
CERTIFICATE: CE
ITEM 001
QUANTITY: ≥ 30,000PIECES
ITEM 002QUANTITY:≥ 10,000PIECES
ITEM 003QUANTITY:≥ 1,000PIECES
MARKS: THIS PROTECTIVE CLOTHING/ISOLATION CLOTHING NOT INCLUDED SHOES COVER,NOT USED IN ICU.
Learn More -
P-8696 ULTRASONIC SEWING MACHINELearn MoreREFERENCE NUMBER: P-8696
ULTRASONIC SEWING MACHINE
CAN BE USED WITH EITHER 20 KHz, 30 KHz OR 40 KHz EQUIPMENT
LED DISPLAY FOR EASY PROCESS MONITORING
19” (483mm) THROAT
INDEPENDENT CONTROLS FOR SLITTING AND ROTARY ANVIL WELDING
DUAL SEALING CAPABILITIES WITH INDEPENDENT ADJUSTMENTS
EDGE GUIDING, REWINDING, AND FEED ROLLS CAN BE USED
CAN BE OPERATOR CONTROLLED AS A BENCHTOP UNIT OR INTEGRATED INTO AN EXISTING LINE
QUANTITY: 1
-
T-6575 NON-INVASIVE VENTILATORNON-INVASIVE VENTILATOR
Learn More
CERTIFICATE: CE
MEDICAL VENTILATOR
TECHNICAL PARAMETERS OF DOUBLE LEVEL VENTILATOR
VENTILATOR TYPE: ELECTRIC CONTROL
SCOPE OF APPLICATION: TREATMENT AND TITRATION OF SLEEP APNEA HYPOPNEA SYNDROME, SEVERE SNORING, AND RESPIRATORY INSUFFICIENCY.
DISPLAY INTERFACE: 3.5-INCH LED SCREEN, CHINESE OPERATING SYSTEM
*VENTILATION MODE: CPAP, S, S/T, T
PRESSURE RANGE:
PRESSURE RANGE: 4-30CMH2O (±0.5CMH2O)
PRESSURE ACCURACY: + 0.5CMH2O
PARAMETER SETTING:
DELAYED BOOST: 0-60MIN, SET THE DIVISION INTERVAL 5MIN
INITIAL PRESSURE: 4CMH2O TREATMENT PRESSURE / RESPIRATORY PRESSURE SETTING
THERAPEUTIC PRESSURE: 4-20CMH2O (IN CPAP MODE)
TARGET TIDAL VOLUME: 150ML - 1500ML, ON/ OFF
MAXIMUM SUCTION PRESSURE: 4-30CMH2O, (CAN BE SET WHEN THE TARGET TIDAL VOLUME FUNCTION IS ON)
MINIMUM SUCTION PRESSURE: 4-30CMH2O (NOT HIGHER THAN THE SUCTION PRESSURE), (CAN BE SET WHEN THE TARGET TIDAL VOLUME FUNCTION IS ON)
INSPIRATORY PHASE PRESSURE: 4-30CMH2O
EXPIRATORY PRESSURE: 4-30CMH2O
EXPIRATORY DECOMPRESSION: PATIENT, OFF, 1-3, THREE ADJUSTABLE
MANUAL VOLTAGE REGULATION: 0-2 GEAR, 0-2CMH2O (ONLY AVAILABLE IN CPAP MODE)
INSPIRATORY SENSITIVITY: 1-8 STALLS
EXPIRATORY SENSITIVITY: 1-8 STALLS
RESPIRATORY FREQUENCY: 3-40 TIMES / MIN
INSPIRATORY TIME: 0.3-3.0S
BACKUP RATE: ON / OFF, DEFAULT 10
PRESSURE RISE TIME: 1-4 STALLS
HUMIDIFIER: 1-5 ADJUSTABLE IN 5 GEARS
*TITRATION FUNCTION: SUPPORT MANUAL AND AUTOMATIC PRESSURE TITRATION, BUILT-IN REMOTE WIRELESS COMMUNICATION MODULE, COMPLETE THE RANDOM SWITCHING OF SINGLE AND DOUBLE LEVEL MODES IN THE TITRATION PROCESS, AND CONTROL MORE THAN 11 VENTILATOR PARAMETERS AT THE SAME TIME.
AUXILIARY FUNCTION: AUTOMATIC AIR LEAKAGE COMPENSATION, AUTOMATIC STARTUP, AUTOMATIC SHUTDOWN, DELAYED SHUTDOWN, SCREEN BACKLIGHT ADJUSTMENT
MONITORING PARAMETERS: PRESSURE, TIDAL VOLUME, RESPIRATORY RATE, MINUTE VENTILATION VOLUME, AIR LEAKAGE VOLUME, INSPIRATORY TIME, BLOOD OXYGEN SATURATION
WAVY CURVE: PRESSURE TIME WAVEFORM, FLOW RATE TIME WAVEFORM
ALARM PROMPT: PIPELINE AND MASK FALLING OFF, AIR LEAKAGE PROMPT, POWER INTERRUPTION, TREATMENT MACHINE FAILURE, HUMIDIFIER FAILURE, LOW VOLTAGE, HIGH RESPIRATORY RATE, LOW RESPIRATORY RATE, LOW MINUTE VENTILATION VOLUME, LOW BLOOD OXYGEN, REPLACEMENT OF FILTER COTTON, FULL SD CARD, RE INSERTION OF SD CARD
*DATA MANAGEMENT:
NETWORK DATA: BMC + RESPIRATORY HEALTH MANAGEMENT CLOUD PLATFORM
SD CARD DATA: RESART NPAP DATA ANALYSIS SOFTWARE
PARTS:
SD CARD: STANDARD
SD CARD SLOT: STANDARD
PIPING: 9 22MM, 1.8M LONG
FACE SHIELD: F2 NOSE MASK AS STANDARD
NOISE: LESS THAN 30DB
ENVIRONMENT CONDITION:
TEMPERATURE:
(WHEN USED) 5 -35 C
(DURING TRANSPORTATION AND STORAGE) -20 C -55 C
ATMOSPHERIC PRESSURE:
(WHEN USED) 760-1060HPA
(DURING TRANSPORTATION AND STORAGE) 760-1060HPA
WORKING HOURS: MORE THAN 8 HOURS
POWER SUPPLY REQUIREMENTS:
AC VOLTAGE: 100-240V
FREQUENCY: 50HZ/60HZ
INPUT POWER: LESS THAN 2A
WATERPROOF LEVEL: IP22 - DRIP PROOF EQUIPMENT
INSTRUMENT SIZE: 290mm X 180mm X 134mm
WEIGHT: 1.5KG (EXCLUDING HUMIDIFIER) 2.5KG (INCLUDING HUMIDIFIER)
ITEM 001
QUANTITY: 10 SETS-999 SETS
ITEM 002
QUANTITY: 1,000 SETS-9,999SETS
ITEM 003
QUANTITY: ≥10,000 SETS -
V-1820 MASK AND RESPIRATOR FIELD TESTERMAINLY USED FOR VISUAL FIELD TESTING OF MASKS AND RESPIRATORS, WHICH IS USEFUL FOR MASK AND RESPIRATOR MANUFACTURERS, QUALITY SUPERVISORS, SCIENTIFIC RESEARCH, AND FOR TESTING PRIOR TO SELLING MASKS.
FEATURES:
1. THE EQUIPMENT IS COMPOSED OF A SEMI-ARC BOW, RECORDING DEVICE, SEAT FRAME AND TEST HEAD DIE.
2. SEMI-ARC BOW: THE RADIUS IS 300 TO 340 mm
CAN BE ROTATED AROUND THE HORIZONTAL RADIUS PLANE PASSING THROUGH THE POINT 0°, AND A SCALE EXTENDING TO THE 90° ARC BOW EVERY 5° FROM 0° ON BOTH SIDES, EQUIPPED WITH SLIDING WHITE VISUAL STANDARD.
3. RECORDING DEVICE: THE RECORDING NEEDLE IS CONNECTED WITH THE VISUAL STANDARD THROUGH COMPONENTS SUCH AS AXLE WHEEL, AND THE DIRECTION AND ANGLE OF THE VISUAL STANDARD ARE RECORDED ON THE VISUAL FIELD DRAWING CORRESPONDINGLY.
4. SEAT FRAME: USED TO SUPPORT SEMI-CIRCULAR ARC BOW AND FIXED RECORDING DEVICE.
5. TEST THE HEAD MOLD: A STANDARD HEAD MOLD, THE TWO EYE HOLES OF THE HEAD MOLD ARE EQUIPPED WITH SMALL LIGHT BULBS, THE POSITION OF THE BULB AND THE POSITION OF THE HEAD MOLD ARE ACCORDING TO THE REQUIREMENTS OF GB 2890. THE TEST HEAD DIE MUST BE INSTALLED ON THE WORKBENCH IN SUCH A WAY THAT THE LEFT AND RIGHT EYES ARE PLACED AT THE CENTER OF THE SEMICIRCULAR ARCH AND THE "0" POINT IS DIRECTLY SEEN.MAIN INDICATORS
Learn More
1. SEMI-CIRCULAR ARC RADIUS: 335mm.
2. LEFT AND RIGHT FIELD OF VIEW: ≤120°.
3. BULB DISTANCE: THE VERTEX OF THE BULB IS CONNECTED AFTER THE TWO EYE POINTS (7±0.5).
APPLICABLE STANDARDS: GB/T 32610-2016, GB 2626-2019, GB2890-2009
