Search results for: 'ins'
- Related search terms
- inspect
- inspectio
- inspection
- instruc
- instruction
- T-6549 CONSTANT TEMPERATURE AND HUMIDITY CHAMBER -FABRIC WATER VAPOR TRANSMISSION RATE
REFERENCE NUMBER: T-6549
CONSTANT TEMPERATURE AND HUMIDITY CHAMBER -FABRIC WATER VAPOR TRANSMISSION RATE
TESTING METER (WITH MOISTURE PERMEABLE CUP)
TECHNICAL DESCRIPTION OF THE INSTRUMENT:
IT IS MAINLY USED TO MEASURE THE MOISTURE PERMEABILITY OF ALL KINDS OF FABRICS, INCLUDING PERMEABLE COATED FABRICS. STRUCTURE PRINCIPLE: ADOPT COMPUTER CONTROL, CREATING A CONSTANT TEMPERATURE, AND HUMIDITY TEST ENVIRONMENT, TEST ENVIRONMENT IN THE CONSTANT TEMPERATURE, AND HUMIDITY, MOISTURE VAPOR TRANSMISSION CUP, PLACED 6 SAMPLE INTO THE GLASS AND THE RUBBER GASKET SEAL, THE CONTAINING HYGROSCOPIC AGENT OR WATER SEAL IS SPECIFIED BY THE WET CUP PLACED IN THE FABRIC SAMPLE TEMPERATURE AND HUMIDITY OF THE ENVIRONMENT, THE SEAL MOISTURE VAPOR TRANSMISSION CUP ACCORDING TO A CERTAIN TIME (INCLUDING SAMPLE AND HYGROSCOPIC AGENT OR WATER) TO CALCULATE THE MOISTURE TRANSMISSION QUALITY CHANGE.
TESTING STANDARD:
GB19082-2009 MEDICAL PRIMARY PROTECTIVE CLOTHING
TECHNICAL REQUIREMENTS GUIDELINES FOR THE SELECTION OF YY-T1498-2016 MEDICAL PROTECTIVE CLOTHING
GB/T12704.1 DETERMINATION OF MOISTURE PERMEABILITY OF FABRICS --HYGROSCOPIC METHOD
DETAILED TECHNICAL SPECIFICATIONS AND CONFIGURATION:
TECHNICAL INDICATORS:
1. TEMPERATURE CONTROL RANGE: -40°C ~ 150°C;RESOLUTION; 0.1 °C
2. HUMIDITY CONTROL RANGE: 50%RH ~ 95% RH±5%
3. SPEED RANGE: 2mm ~ 60mm/MIN
4. CONTROL PRECISION: TEMPERATURE <0.1°C; HUMIDITY + / -1% RH OR LESS
5. CYCLIC WIND SPEED: 0.02 ~ 0.5M/S, 0.3 ~ 0.5M/S
6. TIME CONTROL: 1 ~ 9999H
7. MOISTURE PERMEABLE AREA: 2827 mm 2 (DIAMETER IS 60 mm --NATIONAL STANDARD)
8. QUANTITY OF PERMEABLE CUPS: 6 GB;
9. DRYING BOX CONTROL TEMPERATURE: ROOM TEMPERATURE ~ 199 °C
10. TEST TIME: 1 ~ 999H
11. DRYING BOX STUDIO SIZE: 490 X 400 X 215mm
INSTRUMENT CONFIGURATION:
1. ONE MAIN MACHINE
QUANTITY: 1
Learn More - T-6552 MASK AIR TIGHTNESS TESTER
REFERENCE NUMBER: T-6552
MASK AIR TIGHTNESS TESTER
MASK AIR TIGHTNESS TESTER
HOW TO CHOOSE A HIGH-QUALITY MASK NOT ONLY DEPENDS ON THE FILTERING EFFICIENCY OF THEMASK, BUT ALSO TO CONFIRM WHETHER THE MASK IS COMPLETELY IN CONTACT WITH THE FACE, OTHERWISE AEROSOL PARTICLES SUCH AS GERMS THAT HAVE NOT BEEN FILTERED BY THE MASK WILL BE INHALED FROM THE INADEQUATE ADHESION. THEREFORE, IT IS VERY IMPORTANT TO CHECK THE WEARING STATUS OF THE MASK. THE EUROPEAN AND AMERICAN COUNTRIES HAVE LISTED THE APPLICATION TEST OF THE MASK AS A STRONG INSPECTION ITEM.
FOR EXAMPLE, THE N95 MASK IS ONE OF 9 TYPES OF PARTICULATE PROTECTIVE MASKS CERTIFIED BY NIOSH (NATIONAL INSTITUTE OF OCCUPATIONAL SAFETY AND HEALTH). "N" INDICATES OIL RESISTANCE."95" INDICATES THAT THE PARTICLE CONCENTRATION IN THE MASK IS MORE THAN 95% LOWER THAN THAT OF THE PARTICLES OUTSIDE THE MASK WHEN EXPOSED TO THE SPECIFIED NUMBER OF SPECIAL TEST PARTICLES. N95 IS NOT A SPECIFIC PRODUCT NAME, AS LONG AS IT MEETS THE N95 STANDARD AND PASSES THE NIOSH REVIEW, IT CAN BE CALLED "N95 MASK".
N95 TYPE MASKS, IN ADDITION TO THE FILTERING EFFICIENCY OF THE MASKS, THE CLOSENESS OF THE MASKS TO THE FACE IS ONE OF THE IMPORTANT FACTORS THAT DETERMINE THE EFFECTIVENESS OF THE USE OF THE MASKS. THE SUITABILITY OF DIFFERENT TYPES OF MASKS FOR THE HUMAN FACE VARIES GREATLY.
THEREFORE, BEFORE USING A MASK, THE SUITABILITY OF THE MASK SHOULD BE CHECKED FIRST. DURING THETIGHTNESS TEST OF THE WEARER'S FACE, ENSURE THAT AIR CAN PASS IN AND OUT THROUGH THE MASK WHEN IT IS CLOSE TO THE EDGE OF THE FACE. THE MASK TIGHTNESS TESTER CAN QUICKLY COMPLETE THE TIGHTNESS TEST OF RESPIRATORS SUCH AS MASKS TO ENSURE THAT IT PROVIDES GOOD PROTECTION PERFORMANCE. IT CONFORMS TO THE CHINESE RESPIRATOR STANDARD GB2626-2019 STANDARD, OSHA / CSA STANDARD AND CHINA GENERAL ADMINISTRATION OF QUALITY SUPERVISION, INSPECTION AND QUARANTINE "GB 19083-2010 TECHNICAL REQUIREMENTS FOR MEDICAL PROTECTIVE MASKS" JOINTLY ISSUED BY THE CHINA NATIONAL STANDARDIZATION ADMINISTRATION COMMITTEE.
ADHESION (SUITABILITY TEST): THE MASK DESIGN SHOULD PROVIDE GOOD ADHESION. THE OVERALL FIT FACTOR OF THE MASK SHOULD NOT BE LESS THAN 100. THIS TEST THE REQUIREMENTS WERE FORMALLY IMPLEMENTED ON AUGUST 1, 2011.
MASK TIGHTNESS TESTER USES CNC TECHNOLOGY, SUITABLE FOR 100 / 99 / P3 / HEPASERIES MASKS DISPOSABLE FILTER MASK TIGHTNESS TEST (INCLUDING DISPOSABLE DUST MASKS SUCH ASN95 / N90 / KN95), GAS MASKS / BREATHING MASKS, ADHESIVENESS TEST OF HALF-MASK AND FULL FACE MASK, INDEPENDENT OR COMPUTER CONTROL, FIVE LANGUAGES SWITCH DISPLAY, EQUIPPED WITH MULTIPLE COMMUNICATION INTERFACES (USB, ETHERNET), WIFI CAN ALSO BE ENABLED, ONE COMPUTERCAN CONTROL FOUR INSTRUMENTS AT THE SAME TIME.PARAMETER:CONCENTRATION RANGE: 0 ~ 100,000 / CM3GRAIN DIAMETER: 0.02 ~ 1.0^MFLOW: SAMPLING FLOW: 100CM3 / MINTOTAL FLOW: 700CM3 / MINCLOSENESS COEFFICIENT TEST: DIRECT TEST (COUT/ CIN)LIQUOR: 99.5% + ISOPROPANOL (ANALYTICAL GRADE)DISPLAY: 7INCH TRUE COLOR TOUCH SCREENCOMMUNICATION INTERFACE: USB X 3 (HOST X 2,DEVICE X 1) ETHERNET INTERFACE X1CONNECTION PORT: ENVIRONMENT PORT, SAMPLING PORTWIFI: EQUIPPEDLANGUAGES: ENGLISH, FRENCH, SPANISH, PORTUGUESE, CHINESEFLOW CONTROL: SENSOR CONTROLPC CONTROLLABLE OPERATION: ONE COMPUTER CAN CONTROL 4 INSTRUMENTS AT THE SAME TIMEDATA OUTPUT FORMAT: MICROSOFT EXCELWORKING TEMPERATURE: 15 ~ 35 °CPOWER SOURCE: AC 110 —240V 50 / 60HZAPPEARANCE SIZE: 208 X 117 X 262MMWEIGHT: 2.1KGACCESSORIES: ALCOHOL REAGENT BOTTLE, PROTECTIVE CAP, REAGENT STICK, ZERO-COUNT FILTER, STRAINER, SAMPLING TUBE, INSTRUCTION MANUAL, AC ADAPTER, TOUCH SCREEN PEN, OPTIONAL COMPUTER.OPTIONAL: TEST KIT FOR TIGHTNESS COEFFICIENTIN ORDER TO PREVENT INFECTION AT THE MEDICAL SITE AND DURING LABOR WORK, WORKERS MUST BE PROTECTED FROM INHALABLE HAZARDOUS SUBSTANCES IN THE WORKPLACE, AND RESPIRATORS SUCH AS MASKS MUST BE WORN DURING WORK.SELECT A RESPIRATOR, SUCH AS A MASK, BASED ON YOUR FACIAL FEATURES, AND EVALUATE THE TIGHTNESS BETWEEN THE RESPIRATOR, SUCH AS A MASK AND THE FACE, TO CHECK WHETHER THERE ARE GAPS OR LEAKS THAT PUT WORKERS AT RISK. THE MASK TIGHTNESS TESTER CAN QUICKLY COMPLETE THE TIGHTNESS TEST OF RESPIRATORS SUCH AS MASKS TO ENSURE THAT IT PROVIDES GOOD PROTECTIVE PERFORMANCE. SECURITY EXPERTS WILL ALSO DEVELOP PROTECTION SCHEMES AND STANDARD REGULATIONS BASED ON THE RESULTS OF THE TIGHTNESS TEST. WIDELY USED IN HOSPITALS, MANUFACTURING PLANTS, PRODUCTION SITES, FIREFIGHTING WORKPLACES AND OTHER OFFICIAL TESTING AGENCIES.MASK TIGHTNESS TESTER FEATURES:• QUANTITATIVE TIGHTNESS TEST FOR RESPIRATORS SUCH AS MASKS (QNFT)• APPLICABLE TO 100/99 / P3 / HEPA SERIES MASK DISPOSABLE FILTER MASK TIGHTNESS TEST (INCLUDING N95 / N90 / KN95 AND OTHER DISPOSABLE DUST MASKS)• ADHESION TEST OF HALF MASK AND FULL FACE MASK• GAS MASK TIGHTNESS TEST• PAPR MASK TIGHTNESS TEST• SCBA RESPIRATOR MASK TIGHTNESS TEST• 7INCH TRUE COLOR TOUCH SCREEN• INDEPENDENT OR COMPUTER CONTROLLED• USING CNC TECHNOLOGY• ENGLISH, FRENCH, SPANISH, PORTUGUESE, CHINESE LANGUAGE SWITCHING DISPLAY• COMPLIES WITH US OSHA STANDARDS, CANADIAN STANDARDS ASSOCIATION (CSA) GUIDELINES, INCLUDING N95• EQUIPPED WITH A VARIETY OF COMMUNICATION INTERFACES (USB, ETHERNET), AND CAN ALSO ENABLE WIFI• ONE COMPUTER CAN CONTROL FOUR INSTRUMENTS AT THE SAME TIMEQUANTITY: 1 - H-2414 FAQ for FACIAL RECOGNITION AND TEMPERATURE MEASURING SYSTEM, 8 inch panel
How does it work?
Learn More
What's the system function?
Can it be used as an attendance control unit? - L-7129 NONWOVEN SMS PRODUCTION LINE, 1600mm, SPUNBONDED, MELT BLOWN
PP CHIPS FOR MELTBLOWN: 1200 TO 2000
FABRIC WIDTH: 1600mm
2 SPINNING BEAMS FOR SPUNBOND & 1 FOR MELTBLOWN
BASIC WEIGHT: SMS 9 TO 80 GRAMS PER SQUARE METER
SS: 15 TO 100 GRAMS PER SQUARE METERPRODUCT:
SMS LAMINATED NONWOVEN FABRIC
SS SPUNBOND NONWOVEN FABRIC SS
M MELTBLOWN NONWOVEN FABRIC MTO MAKE HYGENIC FABRICS SUCH AS BABY DIAPERS, SANITARY NAPKINS, ADULT DIAPERS, MEDICAL OPERATION SUITS, OPERATION CAPS, OPERATIONS SHOES, MASKS, ETC.
CONSISTING OF:
3 X FEEDING SYSTEMS
AUTOMATIC VACUUM SUCTION FOR BOTH MAIN MATERIAL AND ADDITIVES
CAPACITY (SB + MB) 2 X 520 KGS/H, (SB) 2 X 200 KGS/HR
WITH THREE HOPPERS, THREE SUPPLIYING DEVICESSPUNBOND SYSTEM
2 X EXTRUDERS
DIAMETER: 150mm
CAPACITY: 450 KGS/HR
L/D 30:1
DRIVE POWER: 110 KW
HEATING POWER: 90 KW2 X RECYCLING SYSTEMS
DIAMETER: 105mm
CAPACITY: 100 KGS PER HOUR
L/D: 15:12 X MELT FILTERS
WORKING TEMPERATURE: UP TO 280 CELSIUS
FILTRATION CAPACITY: 520 KGS PER HOUR2 X METERING PUMPS
TYPE: GEAR PUMP
FLOW VOLUME: 250 ML/R
DESIGNING TEMPERATURE: 280 CELSIUS2 X MELT PIPELINES
WITH STATIC MIXER2 X MONOMER EXHAUSTER
INCLUDING BLOWER, CHILLER, PIPELINE, VALVE, INSULATION, ETC2 X SPINNING BEAMS
SINGLE COAT-HANGER MELT DISTRIBUTION
DESIGNING PRESSURE: 9MPA
WORKING TEMPERATURE: MAX 280 CELSIUS4 X SPINNERETS
HOLE DIAMETER: 0.45mm
L/D: 5:1
15,500 HOLESMELTBLOWN SYSTEM
1 X EXTRUDER
DIAMETER 120mm
CAPACITY: 280 KGS/HR
L/D: 30:1
DRIVE POWER: 75 KW
HEATING POWER: 80 KW1 X MELT FILTER
FILTRATION PRECISION: 20 TO 60 MICROMETERS
FILTRATION: 280 KGS PER HOUR1 X METERING PUMP
GEAR PUMP
MAX. FLOW VOLUME: 100ML/R
DESIGNED TEMPERATURE: 300 CELSIUS1 X MELT PIPELINE
WITH STATIC MIXER1 X SPINNING BEAM
INCLUDING STRETCHING CHANNEL, NOZZLE, ETC. WITH INSULATION MATERIAL
DESIGNED PRESSURE: 6 MPA2 X SPINNING DIE PACKS
COMPACT DIE PACKS
HOLE DIAMETER: 0.35mm
L/D: 12:1
# OF HOLES: 42HPI1 X SCREW BLOWER
INCLUDING MUFFLE, PRESSURE REDUCER VALVE, PIPELINE, ETC.
POWER: 200 KW1 X HOT AIR SYSTEM
FLOW VOLUME: 6000 CUBIC METERS PER HOUR
WORKING TEMP: MAX 350 CELSIUS
INCLUDING HEATER, STAINLESS STEEL PIPELINE, ETC.
POWER: 290 KW1 X OFF-LINE CONVEYOR
RANGE OF SPEED: 5 TO 100 METERS PER MINUTE1 X CONVEYOR
MECHANICAL SPEED: MAX 400 METERS PER MINUTE
BELT WIDTH AND PENETRATION
3800±10mm, 10000 CUBIC METERS PER H.M21 X CALENDAR
DOUBLE ROLLS HEATED BY OIL
PROCESS SPEED: 350 METERS PER MINUTE
EMBOSSING WIDTH: UP TO 2000mm
MAX LINEAR PRESSURE: 110 DAN/C
MAX. TEMP OF EMBOSSING ROLLER, 180 CELSIUS1 X WINDER
ONLINE CHANGING ROLL, ONLINE EDGE CUTTING, TENSION CONTROL
MAX. LINEAR SPEED: 350 METERS PER MINUTE
WIDTH: 1600mm
WIND DIAMETER: MAX 1500mm1 X SLITTER
MAX. LINE SPEED: 600 METERS PER MINUTE
MAX. WIND DIAMETER: 1200mm
MIN. SLITTING WIDE: 120mm
22 CIRCULAR BLADES1 X STEEL PLATFORM
1 X ELECTRICAL CONTROL SYSTEM
2 X OIL OVEN
1 X AIR CONDITIONING SYSTEM
1 X WATER COOLING SYSTEM
1 X CLEANING EQUIPMENTS FOR DIE PACK
1 X AUXILIARY PLATFORM
1 X AUXILIARY EQUIPMENTS
1 X LABORATORY TESTING DEVICE
Learn More - M-6098 PRODUCTION LINE FOR 100% COTTON CREPE BANDAGES
REFERENCE NUMBER: M-6098
PRODUCTION LINE FOR 100% COTTON CREPE BANDAGESFOR AUTOMATIC AND CONTINUOUS PRODUCTION OF 100% COTTON CREPE BANDAGES FROM 100% COTTON GAUZE FABRICS. THE PRODUCTION LINE HAS 3 CONTINUOUS FUNCTIONS REALIZED BY 3 MACHINES
Learn More - V-0025 COTTON PAD, BALL, SWAB MACHINESREFERENCE NUMBER: V-0025 COTTON PAD, BALL, SWAB MACHINES M-5138 SQUARE COTTON PAD PRODUCTION MACHINE M-5139 COTTON GAUZE PAD PRODUCTION MACHINE M-5140 MACHINE TO PRODUCE VARIOUS TYPES OF COTTON PADS M-5141 COTTON PAD PRODUCTION MACHINE M-5142 MAKEUP REMOVING COTTON PAD PRODUCTION MACHINE M-5143 ROUND COTTON PAD MAKING MACHINE M-5144 SQUARE ABSORBENT COTTON PAD PRODUCTION MACHINE M-5145 ROUND ABSORBENT COTTON PAD PRODUCTION MACHINE M-5146 ROUND COTTON PADS MAKING MACHINE M-5147 COTTON PAD MAKING MACHINE M-5148 COTTON PAD MAKING MACHINE M-5168 COTTON PADS MAKING MACHINE M-5169 COTTON Q-TIP MAKING MACHINE (100PCS/BAG) M-5170 COTTON BALL MAKING MACHINE (NEW) M-5171 COSMETIC COTTON PAD (GLOVE SHAPE) MAKING MACHINE M-5172 COSMETIC COTTON PAD MAKING MACHINE (ROUND PAD) M-5101 MEDICAL COTTON BALL MAKING MACHINE 20KG/HOUR QUANTITY AVAILABLE: 17 Learn More
- M-5142 MAKEUP REMOVING COTTON PAD PRODUCTION MACHINEREFERENCE NUMBER: M-5142 (1212QAZCXX11) L MAKEUP REMOVING COTTON PAD PRODUCTION MACHINE INSERTING STYLE MAKEUP REMOVING COTTON MACHINE MODEL: RE RAW MATERIAL WIDTH: 95CM; DIAMETER: 70CM SLITTING DEVICE: PUNCHING EMBOSSING DEVICE: HEAT EMBOSSING DEVICE PRODUCT SIZE: CUSTOMIZED COUNTING WAY: LEFT AND RIGHT COUNTING OUTPUTTING WAY: 2 BY 1 SLITTING MATERIAL: COTTON, NONWOVEN, COTTON COMPOSITION MATERIAL PRODUCT FEATURE: INSERTING STYLE COTTON PAD MACHINE CONTROL SYSTEM: FREQUENCY CONTROL OF MOTOR SPEED MOTOR: STEPPING MOTOR PARAMETER-SETTING: COLOR TOUCH SCREEN PRODUCTION SPEED: 600 PIECES PER MINUTE AIR COMPRESSOR: PROVIDED BY YOURSELF PACKING SIZE: DEPENDING ON THE CONFIGURATION POWER: 380V / 50HZ / 3.0KW WEIGHT: ABOUT 1500KG DEPENDING ON THE CONFIGURATION QUANTITY: 1 Learn More
- YY-1136 ULTRAVIOLET STERILIZERYY-1136 ULTRAVIOLET STERILIZER MAINTENANCE OF UV STERILIZER: 1 CHECK REGULARLY TO ENSURE THE NORMAL OPERATION OF THE UV LAMP. 2. AFTER 9000 HOURS OR ONE YEAR OF CONTINUOUS USE, THE ULTRAVIOLET LAMP SHOULD BE REPLACED. WHEN REPLACING A NEW LAMP, FIRST UNPLUG THE POWER SOCKET OF THE LAMP AND TAKE OUT THE ULTRAVIOLET LAMP. PAY ATTENTION NOT TO TOUCH THE QUARTZ GLASS OF THE NEW LAMP WITH YOUR FINGERS, BECAUSE THE STAIN WILL AFFECT THE INTENSITY OF THE LIGHT, AND CAREFULLY PUT THE LAMP INTO THE CHAMBER OF THE STERILIZER. Learn More
- P-8701 MEDICAL PROTECTIVE CLOTHING
REFERENCE NUMBER: P-8701
MEDICAL PROTECTIVE CLOTHING
ADVANTAGES: MOISTURE PERMEABILITY,ANTI TEARING, ANTI-STATIC,ANTI PENETRATIONVIRUS BARRIERAND HIGH STRENGTH OF ANTIBACTERIAL FILM COMPOSITE FABRIC.
STRUCTURE: CONSISTS OF HOODED TOP AND TROUSERS
RANGE: PROVIDE BARRIER AND PROTECTION
PRODUCT SIZE: 165,170,175,180,185
CARTON SIZE: 56X41X36mm
ONE CARTON:30PCS
GROSS WEIGHT: 9.5KG
PACKAGE: PACKED BY PLASTIC, BAG INSIDE AND NORMAL CARTON OUTSIDENO SHOES INCLUDED-NO STOCK
QUANTITY: 1
Learn More - T-6543 MEDICAL UNIVERSAL TENSILE TESTING EQUIPMENT
REFERENCE NUMBER: T-6543
MEDICAL UNIVERSAL TENSILE TESTING EQUIPMENT
SHANDONG INDEPENDENTLY RESEARCH AND DEVELOPMENT THIS COMPREHENSIVE TESTING MACHINE FOR SURGICAL MASK & PROTECTIVE CLOTHING, IT IS WIDELY USED IN A VARIETY OF MASK STRENGTH DETECTION PROJECTS.FEATURES:COMPLY WITH NATIONAL STANDARDS, MEDICAL STANDARDS TESTING REQUIREMENTS, AUTOMATIC SOFTWARE CONTROL SYSTEM, MEET THE REQUIREMENTS OF DATA STORAGE, PRINTING, COMPARISON. THE IMPORTED SERVO MOTOR IS EQUIPPED WITH PRECISION SCREW DRIVE SYSTEM TO ENSURE THE STABILITY OF TEST DATA.
TEST STANDARDS:
GB 19082-2009 TECHNICAL REQUIREMENTS FOR DISPOSABLE PROTECTIVE CLOTHING FOR MEDICAL USE (4.5 BREAKING STRENGTH -THE BREAKING STRENGTH OF MATERIALS IN KEY PARTS OF PROTECTIVE CLOTHING SHOULD NOT BE LESS THAN 45N)
(4.6 ELONGATION AT BREAK -THE ELONGATION AT BREAK OF KEY PARTS OF PROTECTIVE CLOTHING SHOULD NOT BE LESS THAN 15%)
SELF-PRIMING FILTER RESPIRATOR FOR RESPIRATORY PROTECTION ARTICLES5.6.2 BREATHING BONNET -BREATHING BONNET SHALL BE SUBJECT TO AXIAL TENSION"DISPOSABLE MASK: 10N FOR 10S" "REPLACEABLE MASK: 50N FOR 10S"
(5.9 HEADBAND -HEADBAND SHOULD BEAR THE TENSION "DISPOSABLE MASK: 10N, 10S" "REPLACEABLE HALF MASK: 50N FOR 10S" "FULL MASK: 150N FOR 10S")
5.10 JOINTS AND CONNECTING PARTS -JOINTS AND CONNECTING PARTS SHALL BE SUBJECT TO AXIAL TENSION
"REPLACEABLE HALF MASK: 50N FOR 10S" "FULL COVER 250N FOR 10S"
GB/T 32610-2016 TECHNICAL SPECIFICATION FOR DAILY PROTECTIVE MASKS
(6.9 BREAKING STRENGTH OF THE MASK BELT AND THE CONNECTION BETWEEN THE MASK BELT ANDTHE MASK BODY ≥ 20N)
(6.10 FASTNESS TO BREATHING BONNET: NO SLIPPAGE, BREAKAGE OR DEFORMATION SHALL OCCUR)
YY/T 0699-2013 DISPOSABLE SURGICAL MASK
(4.4 MASK BELT -THE BREAKING FORCE AT THE CONNECTION POINT BETWEEN EACH MASK BELT AND THE MASK BODY IS NOT LESS THAN 10N)
YY 0469-2011 SURGICAL MASK FOR MEDICAL USE (5.4.2 MASK BELT)
GB/T 3923.1-1997 DETERMINATION OF BREAKING STRENGTH AND ELONGATION AT BREAK OF FABRICS (STRIP METHOD)
DISPOSABLE RUBBER INSPECTION GLOVES (6.3 TENSILE PROPERTIES)
INSTRUMENT TECHNICAL PARAMETERS:
SPECIFICATION: 200N (STANDARD) 50N, 100N, 500N, 1000N (OPTIONAL)
ACCURACY: BETTER THAN 0.5RESOLUTION OF FORCE VALUE: 0.1N
DEFORMATION RESOLUTION: 0.001mm
TEST SPEED: 0.01mm/MIN ~ 2000mm/MIN (STEPLESS SPEED REGULATION)
WIDTH OF SAMPLE: 30mm (STANDARD FIXTURE) 50mm (OPTIONAL FIXTURE)
CLAMPING OF SAMPLES: MANUAL (PNEUMATIC CLAMPING CAN BE CHANGED)
STROKE: 700mm (STANDARD) 400mm, 1000mm (OPTIONAL)
QUANTITY: 1
Learn More