Search results for: 'Power p'
- Related search terms
- power generat
- power supply
- power gener
- Power pla'
- Power equip
- T-6547 RESPIRATOR RESISTANCE TESTER FOR FACE MASKS
REFERENCE NUMBER: T-6547
RESPIRATOR RESISTANCE TESTER FOR FACE MASKS
INTRODUCTION
THE RESPIRATOR RESISTANCE TESTER IS USED TO MEASURE THE INSPIRATORY RESISTANCE AND EXPIRATORY RESISTANCE OF RESPIRATORS AND RESPIRATOR PROTECTORS UNDER SPECIFIED CONDITIONS. IT IS APPLICABLE TO THE NATIONAL LABOR PROTECTION EQUIPMENT INSPECTION INSTITUTIONS, MASK MANUFACTURERS FOR THE GENERAL MASKS, DUST MASKS, MEDICAL MASKS, ANTI-SMOG MASKS PRODUCTS OF THE RELEVANT TESTING AND INSPECTION.
STANDARD
GB 19083-2010 TECHNICAL REQUIREMENTS FOR MEDICAL PROTECTIVE MASKS
GB 2626-2006 RESPIRATOR SELF-SUCTION FILTER RESPIRATOR AGAINST PARTICULATE MATTER
GB/T 32610-2016 TECHNICAL SPECIFICATIONS FOR DAILY PROTECTIVE MASKS
FEATURES:
1. HIGH-DEFINITION LCD DISPLAY.
2. DIGITAL DIFFERENTIAL PRESSURE METER WITH HIGH PRECISION IMPORTED BRAND.
3. HIGH PRECISION IMPORTED BRAND OF DIGITAL FLOWMETER, WITH HIGH FLOW CONTROL ACCURACY FEATURES.
4. THE RESPIRATOR RESISTANCE TESTER CAN SET UP TWO MODES: EXHALATION DETECTION AND INHALATION DETECTION.
5. AUTOMATIC PIPELINE SWITCHING DEVICE OF RESPIRATOR SOLVES THE PROBLEM OF PIPE EXTUBATION AND WRONG CONNECTION WHEN TESTING.
PARAMETER:
1. FLOWMETER RANGE: 0 ~ 100L/MIN, ACCURACY IS 3%
2. DIGITAL PRESSURE DIFFERENCE METER RANGE: 0 ~ 2000PA, ACCURACY: 1PA
3. PUMPING CAPACITY OF AIR PUMP: >100L/MIN
4. OVERALL SIZE: 460 X 1080 X 670mm
5. POWER SOURCE: AC220V 50HZ 650W
6. WEIGHT: 55KG
QUANTITY: 1
Learn More - T-6552 MASK AIR TIGHTNESS TESTER
REFERENCE NUMBER: T-6552
MASK AIR TIGHTNESS TESTER
MASK AIR TIGHTNESS TESTER
HOW TO CHOOSE A HIGH-QUALITY MASK NOT ONLY DEPENDS ON THE FILTERING EFFICIENCY OF THEMASK, BUT ALSO TO CONFIRM WHETHER THE MASK IS COMPLETELY IN CONTACT WITH THE FACE, OTHERWISE AEROSOL PARTICLES SUCH AS GERMS THAT HAVE NOT BEEN FILTERED BY THE MASK WILL BE INHALED FROM THE INADEQUATE ADHESION. THEREFORE, IT IS VERY IMPORTANT TO CHECK THE WEARING STATUS OF THE MASK. THE EUROPEAN AND AMERICAN COUNTRIES HAVE LISTED THE APPLICATION TEST OF THE MASK AS A STRONG INSPECTION ITEM.
FOR EXAMPLE, THE N95 MASK IS ONE OF 9 TYPES OF PARTICULATE PROTECTIVE MASKS CERTIFIED BY NIOSH (NATIONAL INSTITUTE OF OCCUPATIONAL SAFETY AND HEALTH). "N" INDICATES OIL RESISTANCE."95" INDICATES THAT THE PARTICLE CONCENTRATION IN THE MASK IS MORE THAN 95% LOWER THAN THAT OF THE PARTICLES OUTSIDE THE MASK WHEN EXPOSED TO THE SPECIFIED NUMBER OF SPECIAL TEST PARTICLES. N95 IS NOT A SPECIFIC PRODUCT NAME, AS LONG AS IT MEETS THE N95 STANDARD AND PASSES THE NIOSH REVIEW, IT CAN BE CALLED "N95 MASK".
N95 TYPE MASKS, IN ADDITION TO THE FILTERING EFFICIENCY OF THE MASKS, THE CLOSENESS OF THE MASKS TO THE FACE IS ONE OF THE IMPORTANT FACTORS THAT DETERMINE THE EFFECTIVENESS OF THE USE OF THE MASKS. THE SUITABILITY OF DIFFERENT TYPES OF MASKS FOR THE HUMAN FACE VARIES GREATLY.
THEREFORE, BEFORE USING A MASK, THE SUITABILITY OF THE MASK SHOULD BE CHECKED FIRST. DURING THETIGHTNESS TEST OF THE WEARER'S FACE, ENSURE THAT AIR CAN PASS IN AND OUT THROUGH THE MASK WHEN IT IS CLOSE TO THE EDGE OF THE FACE. THE MASK TIGHTNESS TESTER CAN QUICKLY COMPLETE THE TIGHTNESS TEST OF RESPIRATORS SUCH AS MASKS TO ENSURE THAT IT PROVIDES GOOD PROTECTION PERFORMANCE. IT CONFORMS TO THE CHINESE RESPIRATOR STANDARD GB2626-2019 STANDARD, OSHA / CSA STANDARD AND CHINA GENERAL ADMINISTRATION OF QUALITY SUPERVISION, INSPECTION AND QUARANTINE "GB 19083-2010 TECHNICAL REQUIREMENTS FOR MEDICAL PROTECTIVE MASKS" JOINTLY ISSUED BY THE CHINA NATIONAL STANDARDIZATION ADMINISTRATION COMMITTEE.
ADHESION (SUITABILITY TEST): THE MASK DESIGN SHOULD PROVIDE GOOD ADHESION. THE OVERALL FIT FACTOR OF THE MASK SHOULD NOT BE LESS THAN 100. THIS TEST THE REQUIREMENTS WERE FORMALLY IMPLEMENTED ON AUGUST 1, 2011.
MASK TIGHTNESS TESTER USES CNC TECHNOLOGY, SUITABLE FOR 100 / 99 / P3 / HEPASERIES MASKS DISPOSABLE FILTER MASK TIGHTNESS TEST (INCLUDING DISPOSABLE DUST MASKS SUCH ASN95 / N90 / KN95), GAS MASKS / BREATHING MASKS, ADHESIVENESS TEST OF HALF-MASK AND FULL FACE MASK, INDEPENDENT OR COMPUTER CONTROL, FIVE LANGUAGES SWITCH DISPLAY, EQUIPPED WITH MULTIPLE COMMUNICATION INTERFACES (USB, ETHERNET), WIFI CAN ALSO BE ENABLED, ONE COMPUTERCAN CONTROL FOUR INSTRUMENTS AT THE SAME TIME.PARAMETER:CONCENTRATION RANGE: 0 ~ 100,000 / CM3GRAIN DIAMETER: 0.02 ~ 1.0^MFLOW: SAMPLING FLOW: 100CM3 / MINTOTAL FLOW: 700CM3 / MINCLOSENESS COEFFICIENT TEST: DIRECT TEST (COUT/ CIN)LIQUOR: 99.5% + ISOPROPANOL (ANALYTICAL GRADE)DISPLAY: 7INCH TRUE COLOR TOUCH SCREENCOMMUNICATION INTERFACE: USB X 3 (HOST X 2,DEVICE X 1) ETHERNET INTERFACE X1CONNECTION PORT: ENVIRONMENT PORT, SAMPLING PORTWIFI: EQUIPPEDLANGUAGES: ENGLISH, FRENCH, SPANISH, PORTUGUESE, CHINESEFLOW CONTROL: SENSOR CONTROLPC CONTROLLABLE OPERATION: ONE COMPUTER CAN CONTROL 4 INSTRUMENTS AT THE SAME TIMEDATA OUTPUT FORMAT: MICROSOFT EXCELWORKING TEMPERATURE: 15 ~ 35 °CPOWER SOURCE: AC 110 —240V 50 / 60HZAPPEARANCE SIZE: 208 X 117 X 262MMWEIGHT: 2.1KGACCESSORIES: ALCOHOL REAGENT BOTTLE, PROTECTIVE CAP, REAGENT STICK, ZERO-COUNT FILTER, STRAINER, SAMPLING TUBE, INSTRUCTION MANUAL, AC ADAPTER, TOUCH SCREEN PEN, OPTIONAL COMPUTER.OPTIONAL: TEST KIT FOR TIGHTNESS COEFFICIENTIN ORDER TO PREVENT INFECTION AT THE MEDICAL SITE AND DURING LABOR WORK, WORKERS MUST BE PROTECTED FROM INHALABLE HAZARDOUS SUBSTANCES IN THE WORKPLACE, AND RESPIRATORS SUCH AS MASKS MUST BE WORN DURING WORK.SELECT A RESPIRATOR, SUCH AS A MASK, BASED ON YOUR FACIAL FEATURES, AND EVALUATE THE TIGHTNESS BETWEEN THE RESPIRATOR, SUCH AS A MASK AND THE FACE, TO CHECK WHETHER THERE ARE GAPS OR LEAKS THAT PUT WORKERS AT RISK. THE MASK TIGHTNESS TESTER CAN QUICKLY COMPLETE THE TIGHTNESS TEST OF RESPIRATORS SUCH AS MASKS TO ENSURE THAT IT PROVIDES GOOD PROTECTIVE PERFORMANCE. SECURITY EXPERTS WILL ALSO DEVELOP PROTECTION SCHEMES AND STANDARD REGULATIONS BASED ON THE RESULTS OF THE TIGHTNESS TEST. WIDELY USED IN HOSPITALS, MANUFACTURING PLANTS, PRODUCTION SITES, FIREFIGHTING WORKPLACES AND OTHER OFFICIAL TESTING AGENCIES.MASK TIGHTNESS TESTER FEATURES:• QUANTITATIVE TIGHTNESS TEST FOR RESPIRATORS SUCH AS MASKS (QNFT)• APPLICABLE TO 100/99 / P3 / HEPA SERIES MASK DISPOSABLE FILTER MASK TIGHTNESS TEST (INCLUDING N95 / N90 / KN95 AND OTHER DISPOSABLE DUST MASKS)• ADHESION TEST OF HALF MASK AND FULL FACE MASK• GAS MASK TIGHTNESS TEST• PAPR MASK TIGHTNESS TEST• SCBA RESPIRATOR MASK TIGHTNESS TEST• 7INCH TRUE COLOR TOUCH SCREEN• INDEPENDENT OR COMPUTER CONTROLLED• USING CNC TECHNOLOGY• ENGLISH, FRENCH, SPANISH, PORTUGUESE, CHINESE LANGUAGE SWITCHING DISPLAY• COMPLIES WITH US OSHA STANDARDS, CANADIAN STANDARDS ASSOCIATION (CSA) GUIDELINES, INCLUDING N95• EQUIPPED WITH A VARIETY OF COMMUNICATION INTERFACES (USB, ETHERNET), AND CAN ALSO ENABLE WIFI• ONE COMPUTER CAN CONTROL FOUR INSTRUMENTS AT THE SAME TIMEQUANTITY: 1 - T-6592 INFRARED THERMOMETER
REFERENCE NUMBER: T-6592
INFRARED THERMOMETER
INFRARED THERMOMETER
DATA FOMART RESOLUTION 0.1°C(0.1°C)
AMBIENT TEMPERATURE 10-40°C
STORAGE TEMPERATURE 0-50°C
RELATIVE HUMIDITY<80%
POWER SUPPLY DC9V(NOT INCLUDED)
PRODUCT SIZE 160X100X40mm
GROSS WEIGHT 125G WITHOUT BATTERY
RANGE OF TEMPERATURE
BODY TEMPERATURE MODE (32°C-42.5°C)
ACCTURACY ±0.3°C(0.45°F)
MEASUREMENT DISTANCE 50 TO 100mm
EVERY FAMILY NEEDS A THERMOMETER AND PAY ATTENTION FOR THE HEALTH OF YOUR FAMILY
LEAD TIME-SHIPPING TIME 5-7 DAYS BY FEDEX:MASS GOODS: 2-4 DAYS
ITEM 001
QUANTITY: 100
ITEM 002
QUANTITY: 500
LEAD TIME-SHIPPING TIME 5-7 DAYS BY FEDEX:MASS GOODS: 5-10 DAYS
ITEM 003
QUANTITY: 1,000
ITEM 004
QUANTITY: 3,000
ITEM 005
QUANTITY: 5,000
Learn More - J-2813 HANDHELD AIRBORNE PARTICLE COUNTER, MODEL 3000
FEATURES
0.3 - 25 µm SENSITIVITY
FLOW RATE: 1.0 CFM (28.3 LPM)
UP TO 8 CHANNELS OF SIMULTANEOUS COUNT DATA
21 CFR PART 11 COMPLIANT SECURE USB FLASH TRANSFER
EXTREME LIFE LASER DIODE TECHNOLOGY >20-YEAR MTTF
5.7 INCH COLOR TOUCH SCREEN DISPLAY
THERMAL PRINTER
STAINLESS STEEL CONSTRUCTION
ETHERNET/RS485/MODBUS, 4x 4-20mA ANALOG INPUTS
3,000 RECORD DATA STORAGE
50-RECORD CONFIGURABLE RECIPE DATABASE
REPORT WIZARD: FS-209E, ISO-14644-1 & EU GMP ANNEX 1
2 YEAR WARRANTYSTANDARD 6 CHANNELS: 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm , 0.3, 0.5, 1.0, 5.0, 10.0, 25.0 µm
STANDARD 8 CHANNELS: 0.3,0.5,0.7,1.0,3.0,5.0,7.0,10.0 µm
OPTIONAL 8 CHANNELS: OPTIONAL BETWEEN 0.3 AND 25.0 µm
COUNTING EFFICIENCY: 50%@0.3µm; 100% FOR PARTICLES > 0.45 µm (PER ISO 21501-4)
CONCETRATION LIMITS: 1,000,000 PARTICLES/FT3, (35,300,000/M3) @ 10% COINCIDENCE LOSS SUITABLE FOR ISO CLASSES 1-8 CLEANROOMS
DIMENSIONS: 9.5”(L) x 8.0”(W) x 10.2”(H) (24.13 x 20.32 x 25.9 cm)
WEIGHT: WITH BATTERY: 13.95 LBS (6.33 KG), WITHOUT BATTERY 12.35 LBS (5.6 KG)INCLUDES
OPERATING MANUAL WITH CD, LMS EXPRESS TRANSFER SOFTWARE DOWNLOAD INSTRUCTIONS, ISOKINETIC SAMPLE PROBE, TRIPOD, TUBING, PURGE FILTER, POWER CABLES, SPARE FUSE, PRINTER, PRINTER PAPERLEAD TIME: 1 TO 2 WEEKS FROM RECEIPT OF ORDER
QUANTITY: 1
Learn More - H-2414 FAQ for FACIAL RECOGNITION AND TEMPERATURE MEASURING SYSTEM, 8 inch panel
How does it work?
Learn More
What's the system function?
Can it be used as an attendance control unit? - M-6440 WARPING MACHINE FOR MEDICAL BANDAGE PLANT
REFERENCE NUMBER: M-6440
WARPING MACHINE FOR MEDICAL BANDAGE PLANT
WARPING MACHINE
ADJUST SPEED BY FREQUENCY CONVERTER, EASY TO ADJUST, SAVES ENERGY
TIGHT PRESS AUTOMATICALLY, PRESSURE IS ADJUSTABLE, EVEN WARPING
COUNT LENGTH AUTOMATICALLY, WARPING LENGTH CAN BE PRE-SET
COMB TYPE EXPANSION REED, OPEN IN TOP, EASY TO ROW LINE AND CONVENIENT TO ADJUST WIDTH
ON BOTH MACHINE HEAD AND CREEL OF YARNS, THERE ARE CONTROL DEVICES FOR STOPPING THE MACHINE WHEN THE YARN BREAKS, TO ENSURE THE MACHINE WILL STOP WHEN THE YARN BREAKS
WARPING SPEED: UP TO 350 METERS PER MINUTE
REMOTE CONTROL TO START AND STOP MACHINE AUTOMATICALLY, AVAILABLE DISTANCE 20M
AVAILABLE WARP ROLL: Ø300mm TO 410mm, INSIDE WARP BEAM LENGTH IS 255mm TO 260mm, IT CAN BE MADE ON CUSTOMERS’ DIFFERENT REQUESTS
MOTOR POWER: 1.5KW
ONE WARPING MACHINE CAN WORK FOR 20 BANDAGE WEAVING MACHINES
QUANTITY: 1
Learn More - V-1467 3 SIDE MEDICAL BANDAGES PACKAGING MACHINE
REFERENCE NUMBER: V-1467
3 SIDE MEDICAL BANDAGES PACKAGING MACHINE
THIS MACHINE IS SUITABLE TO PACK MEDICAL BANDAGES, MEDICINE, FOOD, COMMODITY, ETC.
INCLUDES:
SPECIAL POUCH ADJUSTING SYSTEM, GOOD FOR PACKING PRODUCTS WITH MULTIFORM SIZE, MULTIFORM SPECIFICATION.
COMPUTER CONTROL SYSTEM.
SPECIAL IN-FEED SYSTEM, IN –FEED POSITION CAN BE ADJUSTED DURING MACHINE OPERATION.
SLIPPAGE SEALING SYSTEM CAN ADJUST
PACKAGING FILM THICKNESS: 0.03 TO 0.08mm
SPEED: 40 TO 220 POUCHES PER MINUTE
PACKAGING FILM WIDTH: 100 TO 350mm
FIGURATION (APPROXIMATE): 4350 (L) X 1050 (W) X 1600 (H)
POWER: 3.2 KW
WEIGHT (APPROXIMATE): 500KG
SIZE OF POUCH: ADJUSTABLE, PER CUSTOMER.
QUANTITY: 1
Learn More - V-1472 MEDICAL BANDAGE WEAVING MACHINE
REFERENCE NUMBER: V-1472
MEDICAL BANDAGE WEAVING MACHINE
THIS MACHINE IS SUITABLE TO WEAVE MEDICAL GAUZE BANDAGES, CREPE BANDAGES, PBT ELASTIC BANDAGES, CONFIRMING BANDAGES, ETC. BY CHANGING DIFFERENT KINDS OF RAW MATERIAL.
ADVANTAGES: EASY OPERATION, HIGH EFFICIENCY, STABLE AND RELIABLE PERFORMANCE
BANDAGE WIDTH: 2 TO 20cm
SPEED: 400 TO 800 WEFT/MINUTE
SPECIFICATION: 8/27, 4/75, 2/100, 2/150, 2/200
WEIGHT (APPROXIMATE): 450KG (EXCLUDING CREEL OF YARNS)
POWER: 1.1 KW
QUANTITY : 1
Learn More - M-6096 AUTOMATIC GAUZE BANDAGE ROLLING EQUIPMENT
REFERENCE NUMBER: M-6096
AUTOMATIC GAUZE BANDAGE ROLLING EQUIPMENTRATED POWER: 3KW. H. COMPRESSED AIR PRESSURE REQUIRED30.5 MPA
Learn More
LABOR: 1 PERSON
EQUIPMENT SIZE: 2200mm (L) x 1200mm (W) x 1800mm (H)
NET WEIGHT: 700KG - M-5171 COSMETIC COTTON PAD (GLOVE SHAPE) MAKING MACHINEREFERENCE NUMBER: M-5171 (1313134PT12UX) L COSMETIC COTTON PAD (GLOVE SHAPE) MAKING MACHINE PRODUCTION PROCEDURE INCLUDES FOLDING, WARMING AND EMBOSSING, CUTTING, AUTO COUNT, AND PRODUCT DISCHARGING WITH TWO SETS OF FEEDING, AND SINGLE EXIT DEVICE PRODUCT SIZE ADJUSTABLE INVERTER CONTROL QUANTITY AVAILABLE: 1 Learn More