Search results for: 'ins'
- Related search terms
- inspect
- inspection
- instruct
- ins'
- inst
- K-8046 BBC-ABB 300 MW COAL-OIL-GAS BIOMASS FIRED PLANT YEAR 2006
K-8046 BBC-ABB 300 MW COAL-OIL-GAS BIOMASS FIRED PLANT YEAR 2006
COAL FIRED STEAM TURBINE POWER PLANT
300MW
COAL OIL GAS
BIOMASS FIRED
OUTPUT: 600 MW
180 BAR
540°C
MANUFCATURER/TYPE: BBC-ABB
YEAR: 2006
ONLY 13,300 AND 45,000 RUNNING HOURS AFTER MAJOR OVERHAULALTERNATOR ACEC TC 1498
COOLING: HYDROGEN 22 KV 3000 TR 1550 KVA
MAIN TRAFO: WESTINGHOUSE 375 MVA 156/22 KV
COUPLE TRAFO: ALSTHOM 20 MVA 22/6.4 KV
START TRAFO: ALSTHOM 20 MVA 71.5/6.4 KVFUELPUMPS: ID:3 / HD:3 LD:2881/HD:2223
16 BURNERS TANGENIALGASBURNERS: TANGENIAL 16 PCS 5000 NM3
COAL GRINDING MILLS:
(4) LOESCHE LM 19.20D
25 T/HR(2) LOESCHE LM 20.20D
35 T/HRBIOMASS POWER GENERATION BY CFB (CIRCULATING FLUIDIZED BED) BOILER 20 MWe FIRED BY WOOD DERIVED WASTES CUT INTO CHIPS. COMPLETE SAWDUST INSTALLATION.
UNIT 1
172,000 HOURS, OVERHAULED IN 2006
NEW ROTOR (HD, MD, LD)
ONLY 13,000 HOURS AFTER OVERHAUL
IN PRODUCTION UNTIL JANUARY 5, 2013
SWAP HD ROTOR IN APRIL 2011 ONLY 408 HOURS UNTIL NOW!UNIT 2
265,000 HOURS, OVERHAULED IN 2006 (HD, MD, LD)
45,000 HOURS AFTER OVERHAUL
IN PRODUCTION UNTIL JANUARY 5, 2013
SWAP HD ROTOR IN NOVEMBER 2011 ONLY 13,300 HOURS UNTIL NOW!
189 KG/CM2, 540˚C, 3000 T/MINPLANT ORIGINALLY FROM THW 1970’S BUT RENEWED IN 2006
STILL INSTALLED
IMMEDIATE DISMANTLING POSSIBLE
BOILER INTAKE CAPACITY: 3500 T/H
NEW PLCQUANTITY: 2
Learn More - C-3990 HYUNDAI HIMSEN 9H25/33 HFO POWER PLANT, CAPACITY 10.5 MW, YEAR 2014 - NEW
C-3990 HYUNDAI HIMSEN 9H25/33 HFO POWER PLANT, CAPACITY 10.5 MW, YEAR 2014 - NEW
MAKE/MODEL: HYUNDAI HIMSEN 9H25/33
HFO POWER PLANT
CAPACITY: 10.5 MW
WATTAGE: 46,200 KW
YEAR: 2014
HOURS: NEW
FUEL TYPE: HFO
FREQUENCY: 50 HZ
ENCLOSURE: SOUND ATTENUATED ENCLOSURE
MANUFACTURER: HHI
ENGINE MODEL: HYUNDAI HIMSEN 9H25/33
GENERATOR MODEL: HYUNDAI
FOR 50HZ: 2100KW, 6000V, 750 RPMQUANTITY: 5
Learn More - NATURAL GAS FIRED CHP PLANT WITH JENBACHER 995KW 50HZ GAS GENERATORNATURAL GAS FIRED CHP PLANT WITH JENBACHER 995KW / 50HZ GAS GENERATOR DELIVERED IN YEAR 1997, TOTAL OPERATING HOURS 55,000 GENERATOR DRIVER JENBACHER 20 CYLINDER / 1500 RPM GAS ENGINES TYPE J320 GS N.L. COMPLETE PLANT, ELECTRICAL OUTPUT 995KW 400 / 230V / 40HZ FROM ALTERNATORS HEAT RECOVERY FOR 80 C DEGREE WATER AND STEAM BOILER 6 T/H AT 10 BAR ( SUPPL. FIRED) EQUIPMENT IS STILL INSTALLED AND IN A FAIR CONDITION Learn More
- DUAL FUEL 40MW POWER PLANT WITH SULZER 16 ZAV 40S UNITSDUAL FUEL 40MW WITH 4 X SULZER 16 ZAV 40S UNITS DELIVERED IN YEAR 1991 AND TOTALL REFURBISHED (CONVERTED TO DUAL FUEL IN 2011) TOTAL OPERATING HOURS APPROXIMATELY 30,000 / ENGINES AND APPROXIMATELY 400 AFTER REFURBISHMENT GENERATOR DRIVERS 4 X SULZER 16 CYLINDER / 500 RPM DUAL FUEL ENGINES TYPE 16ZAV40S COMPLETE PLANT, ELECTRICAL OUTPUT 42.2 MW 11 KV / 50 HZ FROM ALTERNATORS THE ENGINES HAVE COOLING TOWER COOLING SYSTEM AND COMPLETE SET OF AXILLARIES EQUIPMENT IS STILL INSTALLED AND IN A GOOD CONDITION Learn More
- DIESEL POWER PLANT 81.3MW WARTSILA 18V46 HFODELIVERED IN YEAR 2001 AND OPERATED UNDER WARTSILA O&M TILL END OF 2012 TOTAL OPERATING HOURS APPROXIMATELY 40,000 / ENGINES AND ALL IN GOOD CONDITION GENERATOR DRIVER 5 X WARTSILA 18 CYLINDER / 500 RPM HFO ENGINES TYPE 18V46 COMPLETE PLANT, ELECTRICAL OUTPUT 81.3MW 11KV / 50HZ FROM ALTERNATORS THE ENGINES HAVE COOLING TOWER COOLING SYSTEM AND COMPLETE SET OF AXILLARIES EQUIPMENT IS STILL INSTALLED AND IN A GOOD CONDITION Learn More