- K-8157 COAL FIRED POWER PLANT (2 X 50MW)
K-8157 COAL FIRED POWER PLANT (2 X 50MW)
ENERGY BOILERS (CAE)
TURBINE SYSTEMS
STEAM TURBINES (TA) - DSL ARE 50 - 1
-CONDENSING TURBINE WITH TWO ADJUSTABLE OUTLETS, SUCH AS "ACTING" ON A SINGLE LINE OF TREES, DESIGNED TO DRIVE THE AC GENERATOR DIRECT-TYPE TH 60-2
-IS COMPOSED OF TWO BODIES: THE BODY OF HIGH PRESSURE (CIP) AND MEDIUM AND LOW PRESSURE BODY (CMP + CJP)
-HAS TWO ADJUSTABLE OUTLETS (PLUG SOCKETS AND PLUG HEATING) AND FIVE FIXED DOSES REGENERATIVE CIRCUIT FEEDSQUARES OF 600 CARS OVER T/H (WITH BUCKET WHEEL AND ARM LENGTH 12 M) - 4 PCS
-TIP HAMMER CRUSHERS CCA - 160 TO 2 PIECES
- RUBBER BANDS COAL TRANSPORTTHE MAIN EQUIPMENT IS ADDED TO ENSURE PROPER OPERATION FOLLOWING:
- SOLID FUEL STORAGE
- INSTALLATIONS AND INDUSTRIAL WATER SUPPLIES AND WASTEWATER DISCHARGE
- INSTALLATION OF EXHAUST HYDRAULIC SLAG
- WATER TREATMENT STATION
TO USE COAL, WEIGHT 88%, 12% NATURAL GASQUANTITY: 1
Learn More - K-8158 COAL FIRED STEAM POWER PLANT 330 MW YEAR 1983
K-8158 COAL FIRED STEAM POWER PLANT 330 MW YEAR 1983
COAL FIRED STEAM POWER PLANT 330 MW
PLANT FOR RELOCATION
EQUIPMENT AND AUXILIARIES IN EXCELLENT CONDITIONSUMMARY OF MAIN ADVANTAGES:
THE STEAM PLANT IS AVAILABLE NOW AND CAN BE REINSTALLED IN SHORT TIME
POWER AVAILABLE IN SHORT TIME
THE EQUIPMENT IS OFFERED AT ATTRACTIVE CONDITIONS
LOW INVESTMENT COST
THE MAIN EQUIPMENT IS BASED ON STATE OF THE ART DESIGN & EMISSION CONTROL
COMMERCIAL LIFE TIME FOR MANY YEARS TO COME
RELOCATION IN COOPERATION WITH OEM SUPERVISING AND GUARANTEES OVERALL CONCEPTTECHNICAL DATA OF BOILER:
OEM
STEAM OUTPUT DESIGN PRESSURE LIVE STEAM REHEAT TEMP FUEL980 T/H
203 BAR
184 BAR / GRAD CBROWN COAL, APPROXIMATELY 9,000 KJ/KG
HARD COAL POSSIBLE AS WELL (24,000 - 28,000 KJ/KG)CONSUMPTION APPROXIMATELY 280 T/H AT FULL LOAD WITH BROWN COAL
APPROXIMATELY 110 T/H AT FULL LOAD WITH HARD COALGRINDING MILLS: 6
EMISSION SO2 200 MG/NM3 X 200 MG/NM3 ASHES 50 MG/NM3 EXHAUST TEMP 70°C
TECHNICAL DATA STEAM TURBINE:
OEM
OUTPUT
LIVE STEAM: 330/345 MW, 177.5 BAR, 535°CGENERAL REMARKS:
PLANT HAS GONE IN COMMERCIAL OPERATION IN 1983
PLANT AND EQUIPMENT HAS BEEN IN OPERATION BASICALLY DURING THE WINTER PERIOD AND HAS 84,300 HOURS ACCUMULATED ONLY
ALL EQUIPMENT IS IN EXCELLENT CONDITION AND PROFESSIONALLY PRESERVEDENTIRE PLANT WITH ALL AUXILIARIES IS AVAILABLE FOR RELOCATION
SCOPE AND CONDITIONS:
DISASSEMBLED, PACKED, AND SHIPPED OR TURNKEY SOLUTION CAN BE NEGOTIATED
RELOCATION WILL BE INCOORDINATION WITH THE OEM WHO IS WILLING TO GIVE A CERTAIN LEVEL OF GUARANTEE FOR THE RELOCATED PLANTQUANTITY: 1
Learn More - C-3991 MAN B&W 18V40/45 HFO POWER PLANT, CAPACITY 10.89 MW, YEAR 1990
C-3991 MAN B&W 18V40/45 HFO POWER PLANT, CAPACITY 10.89 MW, YEAR 1990
MAKE/MODEL: MAN DIESEL MAN B&W 18V40/45
HFO POWER PLANT
CAPACITY: 10.89 MW
WATTAGE: 10,890 KW
YEAR: 1990
FUEL TYPE: HFO
FREQUENCY: 50 HZ
HORSEPOWER: 10890KW
RPM 600QUANTITY: 1
Learn More - JENBACHER LMS612GS GAS POWER PLANT, 2 MW, 50 Hz, YEAR 2011REFERENCE NUMBER: T-6935 JENBACHER LMS612GS GAS POWER PLANT, 2 MW, 50 Hz, YEAR 2011 JENBACHER LMS612GS GAS POWER PLANT COMPLETE POWER PLANT 2,000 KW COP 11,000 V, 50 Hz AVK ALTERNATOR 1,500 RPM RADIATOR, SILENCER, EXHAUST, GAS CONTROL LINE YEAR 2011 APPROX 230 H ONLY QUANTITY: 1 Learn More
- K-8156 SIEMENS SCHUCKERTWERKE AG COAL FIRED POWER PLANT 120 MW YEAR 1967
K-8156 SIEMENS SCHUCKERTWERKE AG COAL FIRED POWER PLANT 120 MW YEAR 1967
COAL FIRED POWER PLANT, 120 MW
MANUFACTURER: SIEMENS - SCHUCKERTWERKE AG
TYPE: CONDENSING - EXTRACTION
FUEL: COAL
SPEED: 3000 U/MIN
POWER: MINIMUM: 125 MW
MAXIMUM: 140 MW
PRESSURE: 185 BAR
TEMPERATURE: 530°C
FREQUENCY: 48.5 - 51.5 HZ
YEAR: 1967
BOILER: BABCOCKSCOPE OF SUPPLY:
-REA AND DENOS (LOW NOx AND SULFUR), INCLUDING SCR-CATALYSATOR AND ELECTROFILTER
-TURBINE
0BOILER
-COAL CRASHER
-COAL BUNKER/STORAGE/TRANSPORTATION
-CONDENSER
-PUMPS AND PIPING
-WATERDEMIRALISTAION
-CHIMNEY
-COOLING SYSTEM AND COOLERS
-LUBRICATION OIL
-COMPRESSOR AIR
-FRESH AIR SYSTEM
-CRANAGE
-ENGINE AND PLANT PLC, MANUFACTURER SIEMENS
-HIGH VOLTAGE
-TRANSFORMER
-ELECTRICAL BOXES AND SWITCHESQUANTITY: 1
Learn More - CUMMINS DIESEL POWER PLANT, 50 MWREFERENCE NUMBER: T-6938 CUMMINS DIESEL POWER PLANT, 50 MW CUMMINS DIESEL POWER PLANT MODEL CUMMINS C2250 D5 ABB ALTERNATOR TANKS, CABINET, PERIPHERALS, ETC. STILL INSTALLED, USED QUANTITY: 1 Learn More
- ALSTOM GAS POWER PLANT, 252 MWREFERENCE NUMBER: T-6937 ALSTOM GAS POWER PLANT, 252 MW ALSTOM GAS POWER PLANT 252 MW WITH SIEMENS TECHNOLOGY STILL INSTALLED, USED ONLY TEST AND MAINTENANCE OPERATION 500 HOURS QUANTITY: 1 Learn More
- M-5238 HFO POWER PLANTS (6MW EACH, TOTAL 24MW) YEAR 2008 – NEW (NEVER USED)REFERENCE NUMBER: M-5238 (1313AJWNXX12U) L HFO POWER PLANTS (6MW EACH, TOTAL 24MW) YEAR 2008 – NEW (NEVER USED) HFO POWER PLANTS 6MW EACH TOTALLING 24MW YEAR 2008 WITH 50HZ NEW (NEVER USED) QUANTITY AVAILABLE: 4 Learn More
- K-2582 SIEMENS COAL AND BIOMASS POWER PLANT 2.5MW YEAR 2002
K-2582 SIEMENS COAL AND BIOMASS POWER PLANT 2.5MW YEAR 2002
WAS BUILT TO SUPPLY THE PAPER MILL WITH STEAM AND ELECTRICITY
MAKE: SIEMENS
MODEL: CFR5 G6a
2.5MW
65 BAR
480 ˚ C
REVOLUTION NUMBER: 23000 U PER MINUTE
EVAPORATION PRESSURE: 1-10 BAR
YEAR 2002
THE STEAM TUBINE AND THE GENERATOR WERE CHANGES AND ARE NEW
HOURS: LESS THAN 30,000
BOILER SYSTEM WAS COMPLETELY RECONDITIONED
THE WATER TREATMENT PLANT WAS RECONDITIONED
EXHAUST CLEANING SYSTEM WAS RECONDITIONED
ASH AND COAL TRANSPORTATION SYSTEMS WERE RECONDITIONEDQUANTITY: 1
Learn More - C-3990 HYUNDAI HIMSEN 9H25/33 HFO POWER PLANT, CAPACITY 10.5 MW, YEAR 2014 - NEW
C-3990 HYUNDAI HIMSEN 9H25/33 HFO POWER PLANT, CAPACITY 10.5 MW, YEAR 2014 - NEW
MAKE/MODEL: HYUNDAI HIMSEN 9H25/33
HFO POWER PLANT
CAPACITY: 10.5 MW
WATTAGE: 46,200 KW
YEAR: 2014
HOURS: NEW
FUEL TYPE: HFO
FREQUENCY: 50 HZ
ENCLOSURE: SOUND ATTENUATED ENCLOSURE
MANUFACTURER: HHI
ENGINE MODEL: HYUNDAI HIMSEN 9H25/33
GENERATOR MODEL: HYUNDAI
FOR 50HZ: 2100KW, 6000V, 750 RPMQUANTITY: 5
Learn More