Search results for: 'Contact++in'
- Related search terms
- Contact++in+euro
- Contact++in+e
- Contact++in+eu
- Contact++in+eur
- AA-1189 CONTAINER LOADING CRANEAA-1189 CONTAINER LOADING CRANE TECHNICAL PARAMETERS: TYPICAL QUAYSIDE CRANE 1. A: GANTRY SPAN: 15000 TO 35000mm 2. C: BACKREACH: 0 TO 25000mm 3. E: CLEARANCE UNDER SILL BEAM: 12000 TO 18000mm 4. G: TRAVEL WHEEL GAUGE: 18200mm 5. H: BUFFER TO BUFFER: 27000mm 6. WHEEL SPACING: 1000 TO 2000mm 7. WHEELS PER CORNER (DEPENDS ON REQUIRED WHEEL LOADS): 6/12 – SEASIDE 8. WHEELS PER CORNER (DEPENDS ON REQUIRED WHEEL LOADS): 6/12 – LANDSIDE 9. MAX. WIDTH TROLLEY AND MAIN BEAM/BOOM: 7600mm Learn More
- Z-1613 AUTOMATIC CARTON PACKAGING MACHINEZ-1613 AUTOMATIC CARTON PACKAGING MACHINE CARTONING FORM: HORIZONTAL CARTONING CARTONING SPEED: 30 TO 40 BOXES PER MINUTE (DEPENDING ON CARTON DIMENSIONS) PROCESS REQUIREMENTS: -AUTOMATIC BOX OPENING, CARTONING -GLUE SPRAYING -BOX SEALING VOLTAGE: 220 VOLTS, 60Hz PLC MICRO COMPUTER FULL AUTOMATIC CONTROL MAN-MACHINE INTERFACE OPERATION SYSTEM (HMI), AUTOMATICALLY DISPLAYS THE PACKING SPEED, QUANTITY, FAULT REASON AND OTHER PERFORMANCE PARAMETERS. THE INDENTATION OF THE CARTON IS GENERALLY: 0.4mm DEEP QUANTITY: 1 Learn More
- A-2572 TUBE FILLING SEALING MACHINE 9.5 KWA-2572 TUBE FILLING SEALING MACHINE 9.5 KW SPECIFICATIONS: SEALING TYPE: HEATING (PLASTIC), FOLDING (ALUMINUM) MAX POWER: 9.5 KW (PLASTIC), 2.3 KW (ALUMINUM) VOLTAGE: 220 VOLTZ AND 50/60 Hz PRODUCTIVITY: 120 TO 150 PCS/Min FILLING VOLUME: 5 TO 250 ML (CHANGE PUMP) TUBE DIAMETER: 10 TO 50 mm (CHANGE MOLDS) TUBE LENGTH: 230 mm (THE MAX.) FILLING ACCURACY: ≤±1% CONTROL: PLC CONTROL SYSTEM DISPLAY: TOUCH SCREEN DISPLAY FEATURE: NO TUBE NO FILLING DIMENSION (L X W X H): 3147 X 1555 X 2267 mm WEIGHT: ABOUT 3800 KG Learn More
- Z-1565 HORIZONTAL LIQUID FILLING MACHINEZ-1565 HORIZONTAL LIQUID FILLING MACHINE MATERIAL: SS316L FOR ALL CONTACT PRODUCTS PART, OTHER PARTS SS304 FILLING RANGE: 100 TO 1000ML FILING SPEED: 0 TO 30BPM (ADJUSTABLE) AIR PRESSURE: 0.5 TO 0.8MPA WORKING PRESSURE: S0.2 TO 0.5MPA AIR CONSUMPTION: 50000mm WEIGHT: 45KG QUANTITY: 1 Learn More
- T-6961 SULZER P7150 B 390 N2 EP R D1 PROJECTILE LOOMS, YEAR 2001, CAM3 HALF WARP BEAMS O 1016mm TUBE 150mm ON LOOM CLOTH ROLL WINDING ALL MACHINES ARE PREPARED FOR SIDE TUCKERS CAM +NEEDLE + NEEDLE ARMS NEEDS TO BE ADDED QUANTITY: 9 Learn More
- HUMAN BODY ELEMENTS ANALYSIS MACHINEREFERENCE NUMBER: Y-2080 HUMAN BODY ELEMENTS ANALYSIS MACHINE HUMAN BODY ELEMENTS ANALYSIS EQUIPMENT, APPLIES THE ACCURATE MEASUREMENTS OF AVR MICROCOMPUTER CONTROLLER BASE ON NEW STATIC METHOD DXA, ANALYSIS HUMAN ELEMENTS, FAT WEIGHT BMI (BODY MASS INDEX), NON-FAT AND OTHER HEALTH INDICATORS THROUGH MULTI-FREQUENCY BIOELECTRICAL IMPEDANCE ANALYSIS METHOD (MFBIA). ALLOW YOU TO LOOSE WEIGHT EFFECTIVELY ON A SCIENTIFIC BASIS. WHICH IS CONSIDERED AS AN EPOCH-MAKING RESULT OF THE HEALTH INDUSTRY. IF YOU ARE A HEALTH CONSULTANT ,IT CAN PROVIDE AN INDEPENDENT ANALYSIS OF HEALTH DATA FOR EACH TEST. APPLICABLE FOR FITNESS CENTERS , MEDICAL CENTERS, SENIOR CLUBS. SUPPORTING PROJECTS OF WEIGHT LOSS . DATA FUNCTION: ANALYSES THE SLIMMING EFFECT TO PROVIDE A THE SLIMMING TREATMENT, ON A SCIENTIFIC BASIS. THE REASONABLE WEIGHT CONTROL HELPS MAINTAIN THE BEST PHYSICAL STRENGTH AND DISTINGUISH BETWEEN MUSCLE TYPE, OVERWEIGHT AND/OR OBESITY. FINDS THE BEST CONTROL WEIGHT METHOD. SUGGESTS DIRECT ENERGY INTAKE AND DIETARY INTAKE OF NUTRIENTS IN CORRECT PROPORTIONS. GUIDING NUTRITION GUIDELINES AND RECOVERY MEASURES TO PROMOTE SYNTHESIS OF MUSCLES MASS. EVALUATION OF THE REHABILITATION TREATMENT EFFECT, GUIDING SCIENTIFIC BODY SLIMMING WITH SCIENTIFIC TRAINING, REHABILITATION, AND NUTRITION. DETECTS THE STATUS OF THE PHYSICAL AND HEALTH OF TEENAGERS, DEVELOPING FOR THEM A FEASIBLE EXERCISE PROGRAM. CLARIFY THE NUTRITION, AND OTHER FACTORS ON BODY COMPOSITION EFFECTS. SUGGEST INCIDENCE OF IMPORTANT PREVENTIVE MEASURES TO ATTEMPT TO REDUCE DIABETES. ADVANTAGES: WITH CE CERTIFICATE IT IS MULTI-FREQUENCY, INCLUDES 20KHz, 50KHz, AND 100KHz. IT CAN MEASURE YOUR WHOLE BODY. IT INCLUDES AN INBUILT MICRO THERMAL PRINTER AND HP COLOR PRINTER AT NO CHARGE THE ELECTRODE METHOD IS 8 POINT CONTACT ELECTRODE WHICH MAKES THE MEASUREMENT MORE ACCURATE. IT ANALYSIS A TOTAL OF 25 VALUE OF BODY COMPOSITIONS AND PROVIDES A HIGHLY ACCURATE WHOLE BODY ANALYSIS IN UNDER 10 SECONDS. THE COMPUTER HAS WIFI AND WIRELESS CONNECTION CAPABILITY SPECIFICATION: INPUT: 220V, 60Hz POWER: 53VA RATED CURRENT: <180μA SIZE: 390mm X 530mm x 1000mm QUANTITY: 1 Learn More
- T-6582 MEDICAL PROTECTIVE SUIT IMPERMEABLE STERILIZED (USED IN INFECTIOUS ISOLATION WARD)
REFERENCE NUMBER: T-6582
MEDICAL PROTECTIVE SUIT IMPERMEABLE STERILIZED (USED IN INFECTIOUS ISOLATION WARD)
MEDICAL PROTECTIVE SUIT IMPERMEABLE STERILIZED (USED IN INFECTIOUS ISOLATION WARD)
1.NP3030: MEDICAL DISPOSABLE PROTECTIVE CLOTHING,STRONG RESISTANT
2.FABRIC: SF 66 G, COLOR: WHITE RUBBER:CAP/FOOT/CUFF/WAIST FRONT FLAP: DOUBLE-SIDED TAPE, TAPE:BLUE TAPE, ETHYLENE OXIDE DISINFECTION, STERILE
3.PACKAGED: 1PC/BAG, 32PCS/CARTON,10KG/CARTONCARTON SIZE: 470 X300 X420mm/CTN
4.NOTE: CLASS II MEDICAL TREATMENT, SCOPE OF USE: MEDICALPERSONNEL CONTACT WITH POTENTIALLY INFECTIOUS PATIENTSBLOOD, BODY FLUIDS, SECRETIONS, PARTICLES IN THE AIR TOPROVIDE BARRIER, PROTECTION. THIS PRODUCT IS USED FORISOLATION OF OBSERVATION WARD (ROOM), ISOLATION WARD(ROOM), ETC. IT IS STRICTLY PROHIBITED TO USE IN THE ISOLATIONCRITICAL CARE WARD (ROOM) AND OTHER PLACES WITH STRICTCONTROL OF MICROBIAL INDICATORS1PC/BAG, 32PCS/CARTON.
WEIGHT AND DIMENSIONS OF CARTONS: 10KG/CARTON
CARTONS IN A 20 FOOT CONTAINER: 370 BOXESSTERILIZED BY ETHYLENE OXIDE GAS
EACH PIECE IS INDIVIDUALLY VACUUM PACKED
1PER PLASTIC POUCH
QUANTITY: 10,000
Learn More - T-6552 MASK AIR TIGHTNESS TESTER
REFERENCE NUMBER: T-6552
MASK AIR TIGHTNESS TESTER
MASK AIR TIGHTNESS TESTER
HOW TO CHOOSE A HIGH-QUALITY MASK NOT ONLY DEPENDS ON THE FILTERING EFFICIENCY OF THEMASK, BUT ALSO TO CONFIRM WHETHER THE MASK IS COMPLETELY IN CONTACT WITH THE FACE, OTHERWISE AEROSOL PARTICLES SUCH AS GERMS THAT HAVE NOT BEEN FILTERED BY THE MASK WILL BE INHALED FROM THE INADEQUATE ADHESION. THEREFORE, IT IS VERY IMPORTANT TO CHECK THE WEARING STATUS OF THE MASK. THE EUROPEAN AND AMERICAN COUNTRIES HAVE LISTED THE APPLICATION TEST OF THE MASK AS A STRONG INSPECTION ITEM.
FOR EXAMPLE, THE N95 MASK IS ONE OF 9 TYPES OF PARTICULATE PROTECTIVE MASKS CERTIFIED BY NIOSH (NATIONAL INSTITUTE OF OCCUPATIONAL SAFETY AND HEALTH). "N" INDICATES OIL RESISTANCE."95" INDICATES THAT THE PARTICLE CONCENTRATION IN THE MASK IS MORE THAN 95% LOWER THAN THAT OF THE PARTICLES OUTSIDE THE MASK WHEN EXPOSED TO THE SPECIFIED NUMBER OF SPECIAL TEST PARTICLES. N95 IS NOT A SPECIFIC PRODUCT NAME, AS LONG AS IT MEETS THE N95 STANDARD AND PASSES THE NIOSH REVIEW, IT CAN BE CALLED "N95 MASK".
N95 TYPE MASKS, IN ADDITION TO THE FILTERING EFFICIENCY OF THE MASKS, THE CLOSENESS OF THE MASKS TO THE FACE IS ONE OF THE IMPORTANT FACTORS THAT DETERMINE THE EFFECTIVENESS OF THE USE OF THE MASKS. THE SUITABILITY OF DIFFERENT TYPES OF MASKS FOR THE HUMAN FACE VARIES GREATLY.
THEREFORE, BEFORE USING A MASK, THE SUITABILITY OF THE MASK SHOULD BE CHECKED FIRST. DURING THETIGHTNESS TEST OF THE WEARER'S FACE, ENSURE THAT AIR CAN PASS IN AND OUT THROUGH THE MASK WHEN IT IS CLOSE TO THE EDGE OF THE FACE. THE MASK TIGHTNESS TESTER CAN QUICKLY COMPLETE THE TIGHTNESS TEST OF RESPIRATORS SUCH AS MASKS TO ENSURE THAT IT PROVIDES GOOD PROTECTION PERFORMANCE. IT CONFORMS TO THE CHINESE RESPIRATOR STANDARD GB2626-2019 STANDARD, OSHA / CSA STANDARD AND CHINA GENERAL ADMINISTRATION OF QUALITY SUPERVISION, INSPECTION AND QUARANTINE "GB 19083-2010 TECHNICAL REQUIREMENTS FOR MEDICAL PROTECTIVE MASKS" JOINTLY ISSUED BY THE CHINA NATIONAL STANDARDIZATION ADMINISTRATION COMMITTEE.
ADHESION (SUITABILITY TEST): THE MASK DESIGN SHOULD PROVIDE GOOD ADHESION. THE OVERALL FIT FACTOR OF THE MASK SHOULD NOT BE LESS THAN 100. THIS TEST THE REQUIREMENTS WERE FORMALLY IMPLEMENTED ON AUGUST 1, 2011.
MASK TIGHTNESS TESTER USES CNC TECHNOLOGY, SUITABLE FOR 100 / 99 / P3 / HEPASERIES MASKS DISPOSABLE FILTER MASK TIGHTNESS TEST (INCLUDING DISPOSABLE DUST MASKS SUCH ASN95 / N90 / KN95), GAS MASKS / BREATHING MASKS, ADHESIVENESS TEST OF HALF-MASK AND FULL FACE MASK, INDEPENDENT OR COMPUTER CONTROL, FIVE LANGUAGES SWITCH DISPLAY, EQUIPPED WITH MULTIPLE COMMUNICATION INTERFACES (USB, ETHERNET), WIFI CAN ALSO BE ENABLED, ONE COMPUTERCAN CONTROL FOUR INSTRUMENTS AT THE SAME TIME.PARAMETER:CONCENTRATION RANGE: 0 ~ 100,000 / CM3GRAIN DIAMETER: 0.02 ~ 1.0^MFLOW: SAMPLING FLOW: 100CM3 / MINTOTAL FLOW: 700CM3 / MINCLOSENESS COEFFICIENT TEST: DIRECT TEST (COUT/ CIN)LIQUOR: 99.5% + ISOPROPANOL (ANALYTICAL GRADE)DISPLAY: 7INCH TRUE COLOR TOUCH SCREENCOMMUNICATION INTERFACE: USB X 3 (HOST X 2,DEVICE X 1) ETHERNET INTERFACE X1CONNECTION PORT: ENVIRONMENT PORT, SAMPLING PORTWIFI: EQUIPPEDLANGUAGES: ENGLISH, FRENCH, SPANISH, PORTUGUESE, CHINESEFLOW CONTROL: SENSOR CONTROLPC CONTROLLABLE OPERATION: ONE COMPUTER CAN CONTROL 4 INSTRUMENTS AT THE SAME TIMEDATA OUTPUT FORMAT: MICROSOFT EXCELWORKING TEMPERATURE: 15 ~ 35 °CPOWER SOURCE: AC 110 —240V 50 / 60HZAPPEARANCE SIZE: 208 X 117 X 262MMWEIGHT: 2.1KGACCESSORIES: ALCOHOL REAGENT BOTTLE, PROTECTIVE CAP, REAGENT STICK, ZERO-COUNT FILTER, STRAINER, SAMPLING TUBE, INSTRUCTION MANUAL, AC ADAPTER, TOUCH SCREEN PEN, OPTIONAL COMPUTER.OPTIONAL: TEST KIT FOR TIGHTNESS COEFFICIENTIN ORDER TO PREVENT INFECTION AT THE MEDICAL SITE AND DURING LABOR WORK, WORKERS MUST BE PROTECTED FROM INHALABLE HAZARDOUS SUBSTANCES IN THE WORKPLACE, AND RESPIRATORS SUCH AS MASKS MUST BE WORN DURING WORK.SELECT A RESPIRATOR, SUCH AS A MASK, BASED ON YOUR FACIAL FEATURES, AND EVALUATE THE TIGHTNESS BETWEEN THE RESPIRATOR, SUCH AS A MASK AND THE FACE, TO CHECK WHETHER THERE ARE GAPS OR LEAKS THAT PUT WORKERS AT RISK. THE MASK TIGHTNESS TESTER CAN QUICKLY COMPLETE THE TIGHTNESS TEST OF RESPIRATORS SUCH AS MASKS TO ENSURE THAT IT PROVIDES GOOD PROTECTIVE PERFORMANCE. SECURITY EXPERTS WILL ALSO DEVELOP PROTECTION SCHEMES AND STANDARD REGULATIONS BASED ON THE RESULTS OF THE TIGHTNESS TEST. WIDELY USED IN HOSPITALS, MANUFACTURING PLANTS, PRODUCTION SITES, FIREFIGHTING WORKPLACES AND OTHER OFFICIAL TESTING AGENCIES.MASK TIGHTNESS TESTER FEATURES:• QUANTITATIVE TIGHTNESS TEST FOR RESPIRATORS SUCH AS MASKS (QNFT)• APPLICABLE TO 100/99 / P3 / HEPA SERIES MASK DISPOSABLE FILTER MASK TIGHTNESS TEST (INCLUDING N95 / N90 / KN95 AND OTHER DISPOSABLE DUST MASKS)• ADHESION TEST OF HALF MASK AND FULL FACE MASK• GAS MASK TIGHTNESS TEST• PAPR MASK TIGHTNESS TEST• SCBA RESPIRATOR MASK TIGHTNESS TEST• 7INCH TRUE COLOR TOUCH SCREEN• INDEPENDENT OR COMPUTER CONTROLLED• USING CNC TECHNOLOGY• ENGLISH, FRENCH, SPANISH, PORTUGUESE, CHINESE LANGUAGE SWITCHING DISPLAY• COMPLIES WITH US OSHA STANDARDS, CANADIAN STANDARDS ASSOCIATION (CSA) GUIDELINES, INCLUDING N95• EQUIPPED WITH A VARIETY OF COMMUNICATION INTERFACES (USB, ETHERNET), AND CAN ALSO ENABLE WIFI• ONE COMPUTER CAN CONTROL FOUR INSTRUMENTS AT THE SAME TIMEQUANTITY: 1 - T-6577 PROTECTION SUIT WITH SHOE COVER
PROTECTION SUIT WITH SHOE COVER
Learn More
HOODED DESIGN
HOODED HEAD DESIGN
ELASTIC DESIGN AT THE MOUTH
CAN ISOLATE DUST AND MICROORGANISMS
SEALED AND PROTECTED BY RUBBER STRIPS
THE WHOLE PIECE DESIGN
EASY TO PUT ON AND TAKE OFF
ELASTIC CUFFS, FLEXIBLE, EFFECTIVE BARRIER, EASIER TO USE
ELASTIC WAISTBAND SLIM ELASTIC WAISTBAND DESIGN, CLOSE THE WAIST, WORK MORE FREELY
CERTIFICATE: CE
MOQ: 1000PCS
MODEL: CONJOINED SPECS: S/160, M/165, L/170, XL/175, XXL/180 ALL SIZES ARE AVAILABLE, PRICES ARE SAME
TYPE:
NON-STERILE: 9.5KG/BOX, 30PCS/BOX, 560 X 430 X 360mm
STERILIZED FOR HOSPITAL: 13KG/BOX, 40PCS/BOX, 600 X 400 X 450mm
PRODUCT DESCRIPTION: CLOTHING MADE FROM FABRICS WITH ISOLATION FUNCTION SUCH AS VIRUS-CONTAINING AEROSOLS AND VIRUS-CONTAINING LIQUIDS. WHEN TAKEN OFF, THE OUTER SURFACE OF THE PROTECTIVE CLOTHING SHOULD NOT COME IN CONTACT WITH THE HUMAN BODY. THIS PRODUCT DOES NOT HAVE FLAME RETARDANT PROPERTIES.
INTENDED USE: OCCUPATIONAL PROTECTIVE CLOTHING FOR MEDICAL PERSONNEL IN MEDICAL INSTITUTIONS TO PREVENT THE TRANSMISSION OF VIRUSES FROM PATIENTS TO THE MEDICAL PERSONNEL WITH AIR OR LIQUID. - D-2380 AUTOMATED FILTER TESTER
THE AUTOMATED FILTER TESTER MODEL 9981 CONTINUES TO BE THE BEST SOLUTION FOR TESTING PARTICULATE RESPIRATOR FILTERS, DISPOSABLE FILTERING FACE PIECES, AND A WIDE ASSORTMENT OF FILTER MEDIA. OUR FILTER TESTERS HAVE BEEN USED IN QUALITY CONTROL AND MANUFACTURING BY LEADING FILTER AND FILTER MEDIA MANUFACTURERS AND REFERENCE TEST INSTITUTES AROUND THE WORLD FOR MORE THAN 20 YEARS DUE TO THEIR PROVEN DURABILITY AND RELIABILITY, WHICH IS VALUED IN DEMANDING MANUFACTURING ENVIRONMENTS AND QA/QC LABORATORIES.
THIS MODEL OFFERS HIGHER SENSITIVITY AND RESOLUTION THAN PREVIOUS MODELS - UP TO 99.9999 PERCENT EFFICIENCY HAS BEEN PRODUCED WITH EMERY OIL AT CONCENTRATIONS OF 200 MG/M³. THE NEW SERVICEABLE PHOTOMETERS ARE LOWERING THE COST OF OWNERSHIP AND ENABLE PROACTIVE SCHEDULING OF MAINTENANCE FOR MINIMAL IMPACT TO PRODUCTION SCHEDULES.
THE MODEL 9981 FEATURES A HIGH DEGREE OF AUTOMATION AND SELF-DIAGNOSTICS THAT GREATLY SIMPLIFIES OPERATION, INCREASES THROUGHPUT, AND IMPROVES OVERALL MEASUREMENT PERFORMANCE. WHEN LOOKING FOR A STAND-ALONE TESTER TO DETERMINE PENETRATION OR FILTER EFFICIENCY AND PRESSURE DROP OF YOUR MEDIA, FILTER CARTRIDGES, FILTERS, AND RESPIRATORY MASKS THE MODEL 9981 IS UP TO THE CHALLENGE.
THE BUILT-IN CAPABILITY TO TEST WITH SALT AND OIL MEANS THAT JUST ONE UNIT IS NEEDED TO TEST YOUR PRODUCT TO:
• US 42 CFR 84, GB2626, JMOL
• ISO 16900-3, EN 143
• ISO 23328-1 (AND MORE)
APPLICATIONS
• USA COMMERCIAL RESPIRATOR REGULATION 42 CFR PART 84
• CHINESE RESPIRATOR STANDARD GB2626
• JAPANESE RESPIRATOR STANDARD JMOL
• EUROPEAN EN 143, ISO 16900-3 AND RELATED RESPIRATOR STANDARDS
• ISO 23328-1 (TESTING FILTERS FOR ANAESTHETIC USE)
• FILTER MEDIA TESTING
• CONSULT OUR REPRESENTATIVE FOR MORE DETAILS
INCLUDED ITEMS
• REFERENCE MEDIA SHEETS
• FLAT-MEDIA AND GRAVIMETRIC FILTER HOLDER
• REFERENCE PRESSURE DROP PLATE
• OIL AND SALT AEROSOL GENERATORS
• SELECTED SPARE PARTS
• CONTACT US FOR CUSTOM FILTER HOLDERSEMAIL US FOR PRICE & PICTURES
Learn More
INCLUDE OUR REFERENCE NUMBER