YY-2285 1.7MW 50Hz HFO BRAND NEW STX-NIIGATA 8L22HLX CPP CONTAINERIZED POWER PLANTYY-2285 1.7MW 50Hz HFO BRAND NEW STX-NIIGATA 8L22HLX CPP CONTAINERIZED POWER PLANT ENGINE MODEL: STX-NIIGATA 8L22HLX; ENGINE OUTPUT: 1760 KWM; GENERATOR OUTPUT: 1680 KWE; GEN-SET DIMENSION (L X W X H): 8019 X 1977 X 2834mm; BORE X STROKE: 220 X 300mm; ENGINE SPEED: 900 / 1000 RPM; FREQUENCY: 60/50Hz; OUTPUT/CYL.: 220 / 220 KW; BMEP: 25.7 / 23.2 BAR; SFOC 1): 186 G/KWMH + 5% TOLERANCE; LO CONSUMPTION: 0.5G/KWMH + 20% TOLERANCE; EMISSION: WB 2007/8; FUEL: DO / HFO / CRUDE OIL/. QUANTITY: 1 Learn More -
YY-2535 GE LM6000PA 42+7MW CHP PLANTYY-2535 GE LM6000PA 42+7MW CHP PLANT THE EXTENSIVE LIST OF ACCOMPANYING EQUIPMENT INCLUDES: 1. GE LM6000PA GAS TURBINE EQUIPPED WITH WATER INJECTION, PAIRED WITH A BRUSH ALTERNATOR WITH 42 MW OUTPUT CAPACITY. THIS GAS TURBINE SUPPORTS NATURAL GAS OR DISTILLATE FUEL. 2. GT MK V CONTROL UNIT WITH AUXILIARY SYSTEMS. 3. SIEMENS BACK PRESSURE STEAM TURBINE WITH 7MW OUTPUT CAPACITY. 4. NOOTER ERIKSON HRSG CAPABLE OF SUPPLEMENTARY FIRING WITH NATURAL GAS OR DISTILLATE FUEL. 5. DUAL BELLIS AND MORCOM THREE-STAGE RECIPROCATING NATURAL GAS COMPRESSORS. 6. WATER TREATMENT PLANT COMPOSED OF TWIN BED RESIN EXCHANGE UNITS AND MIXED BED UNITS. 7. MASSIVE STORAGE TANKS FOR DISTILLATE OIL AND HEAVY FUEL OIL, COMPLETE WITH NECESSARY PIPING AND PUMPS. 8. TWO 11/132 KV TRANSFORMERS RATED AT 40 MVA EACH. 9. STANDBY DIESEL GENERATOR FOR BACKUP POWER. 10. SERCK DISTRIBUTED CONTROL SYSTEM (DCS) FOR INTEGRATED CONTROL AND MONITORING. 11. THREE CONTROL AND GENERAL SERVICE AIR COMPRESSORS. 12. AN EXTENSIVE FIRE DETECTION AND SUPPRESSION SYSTEM, SECURITY CAMERAS, AND GAS DETECTION SYSTEM FOR SAFETY AND SECURITY. 13. A CBISS CONTINUOUS EMISSIONS MONITORING SYSTEM (CEMS) TO ENSURE ADHERENCE TO ENVIRONMENTAL STANDARDS. ALL THE NECESSARY CABLING, TRANSFORMERS, SWITCHGEAR, AND PRESSURE-REDUCING STATIONS ASSOCIATED WITH THE ABOVE-MENTIONED PLANT ARE INCLUDED. A BONUS OF UNIQUE SPARE PARTS, EXTENSIVE MANUALS, RECORDS, AND DRAWINGS ARE ALSO PART OF THE PACKAGE, ENSURING SMOOTH OPERATION AND MAINTENANCE. A GE LM6000PA CHP PLANT REPRESENTS A ROBUST, EFFICIENT SOLUTION TO YOUR POWER AND HEATING NEEDS, OFFERING THE RELIABILITY AND FLEXIBILITY NEEDED FOR YOUR OPERATIONS. QUANTITY: 1 UNIT AVAILABLE FOR PURCHASE Learn More -
TT-1391 GENERAL ELECTRIC LM2500+ G4 GAS TURBINE GENERATORTT-1391 GENERAL ELECTRIC LM2500+ G4 GAS TURBINE GENERATOR GENERAL ELECTRIC LM2500+ G4 GAS TURBINE GENERATOR CONDITION: VERY GOOD AVAILABLE ALSO WITH WARRANTY IN Q1 2023 DELIVERY: FIRST QUARTER OF 2023 QUANTITY: 1 Learn More -
TT-6504 HOWDEN 7MW TWIN CONDENSING STEAM TURBINE, YEAR 2018TT-6504 HOWDEN 7MW TWIN CONDENSING STEAM TURBINE, YEAR 2018 1. HOWDEN 7MW TWIN CONDENSING STEAM TURBINE 2. WITH A.C. GENERATOR 3. MODEL TWIN-CA 56 4. BRAND SIEMENS TURBOMACHINERY EQUIPMENT/TD POWER SYSTEMS SERIES SST-110 QUANTITY: 1 Learn More -
YY-2967 GE 9371FA GAS TURBINE GENERATOR 228.9MW + STEAM TURBINE GENERATOR HARBIN TURBIN/CHINA 127MW, ALTANATOR FOR GT TOSHIBA 299KVA 50Hz, FOR STEAM TURBINE HARBIN 158.824MVA 50HzYY-2967 GE 9371FA GAS TURBINE GENERATOR 228.9MW + STEAM TURBINE GENERATOR HARBIN TURBIN/CHINA 127MW, ALTANATOR FOR GT TOSHIBA 299KVA 50Hz, FOR STEAM TURBINE HARBIN 158.824MVA 50Hz YEAR OF MFG IS 2008 BUT START OPERATION FROM 2012, TOTAL OPERATION HOUR IS 23,000 HOURS. COMPLEX BOROSCOPE INSPECTION MADE ON 2021 AND TOP CONDITION AND NO FURTHER REPAIR MEASURES ARE NECESSARY. Learn More -
YY-3472 44MW WARTSILA POWER PLANT PACKAGEYY-3472 44MW WARTSILA POWER PLANT PACKAGE THE POWER STATION HAS BEEN SUPPLYING ELECTRICITY ON A RENTAL BASIS TO THE 33KV LOCAL GRID SINCE 2011. QUANTITY: 5 Learn More -
C-4026 NUOVO PIGNONE GAS TURBINE, 11 MW AND CONDENSING TURBO GENERATOR SETS, 44.5 MW, YEAR 2002C-4026 NUOVO PIGNONE GAS TURBINE, 11 MW AND CONDENSING TURBO GENERATOR SETS, 44.5 MW, YEAR 2002
OFFER 001
11.7 MWE GAS TURBINE-GENERATOR SETS
GAS TURBINES
MANUFACTURER: NUOVO PIGNONE
MODEL: PGT10B-1
TYPE: MULTI-SHAFT, HEAVY DUTY GAS TURBINE
FUEL: NATURAL GASOFFER 002
ALTERNATOR
MANUFACTURER: ANSALDO
APPARENT POWER: 13,569 KVA
ACTIVE POWER: 11,000 KW
POWER FACTOR: 0.8
RATED SPEED: 1,500 RPMOFFER 003
65.7 TPH WASTE HEAT RECOVERY BOILERS
BOILERS
MANUFACTURER: MACCHI
THERMAL RATING: 55,330 KW
NET THERMAL EFFICIENCY. COP: 90.32%
NET THERMAL EFFICIENCY. COV: 92.48%OFFER 004
44.5 MW CONDENSING TURBO-GENERATOR SET
STEAM TURBINE
MANUFACTURER: NUOVO PIGNONE
MODEL NUMBER: HNK 50/3.2
CONFIGURATION: 1 IMPULSE STAGE 62 REACTION STAGES
RATED POWER: 44,500 KW
RATED INLET FLOW: 131,400 KG/HOFFER 005
GENERATOR
MANUFACTURER: JEUMONT INDUSTRIE
RATED APPARENT POWER: 51,500 KVA
POWER FACTOR: 0.8
ACTIVE POWER: 41,200 KWOFFER 006
CONDENSER
MANUFACTURER: CALDEMON
TYPE: SURFACE CONDENSERQUANTITY: 2
Learn More -
R-6856 FUTURA K AUTOMATIC ROASTING MACHINESR-6856 FUTURA K AUTOMATIC ROASTING MACHINES
AUTOMATIC ROASTING MACHINES RESULT OF LONG STUDIES AND LIVED EXPERIENCE.
THE ROASTING MACHINES SERIES FUTURA K ARE THE RESULT OF LONG STUDIES AND LIVED EXPERIENCE ALONGSIDE OUR CLIENTS COFFEE ROASTERS, FOR THE REALIZATION OF THE MOST ADVANCED MACHINERIES IN THE FIELD OF INDUSTRIAL COFFEE ROASTING.
THE COMPACT DIMENSIONS, RELIABILITY OF THE MATERIALS AND COMPONENTS, THERMAL MANAGEMENT WITH IMMEDIATE RESPONSE, CALIBRATED AND PARTICULARLY FUEL EFFICIENT, HIGH THERMAL AND ACOUSTIC INSULATION AND OTHER POSITIVE FEATURES, MAKE THESE MACHINES REFERENCEGUIDE IN PROFESSIONAL ROASTING FIELD.MAIN COMPONENTS:
FEEDING HOPPER INSULATED WITH PNEUMATIC FILLER DEVICE, MOVABLE INLET, ELECTROPNEUMATIC UNLOADING CONTROL.
ROASTING DRUM MADE BY A FIXED HOUSING WITH DOUBLE INSULATING WALLS FOR THERMAL PROTECTION AND SUPPORTING THE ROTARY CYCLINDER THAT MOVES THE PRODUCT. THE WHOLE CYCLINDER IS MADE OF COMPOUND STEEL TO WITHSTAND THERMAL SHOCKS, ABSOLUTELY ODOURLESS, WITH PERFORATED SHEET FOR PRODUCT CONTAINEMENT, RIGHT AND LEFT BLENDERS SETTLED AT DIFFERENT LEVELS TO OBTAIN PERFECT MIXTURE.
WHEN THE ROASTING PROCESS IS FINISHED, THE COFFEE IS UNLOADED THROUGH A LARGE DOOR WITH ELECTROPNEUMATIC CONTROL OF OPENING AND CLOSING.
THE HEATING GENERATOR IS SPECIFICALLY DESIGNED FOR ROASTING LINE APPLICATIONS. THE PRINCIPLE OF HEATING IS BASED ON HOT AIR FLOWS BY CONVECTION. GAS OR GASOIL BURNER TYPE MODULATING OR MULTI LEVEL- FLAMES ACCORDING THE APPLICATION.
COOLING TANK WITH LARGE STAINLESS STEEL SURFACE, SELF CLEANING, WHERE THE PRODUCT IS MOVED BY MEANS OF 4 CROSSED ARMS. TWO DISCHARGES: ONE IS ELECTROPNEUMATICALLY DRIVEN AND THE OTHER IS MANUAL FOR EMERGENCY. DOOR OF INSPECTION AND EASY CLEANING OF THE LOWER SIDE.
PELLICLES SEPARATOR WITH EXTRACTION, BY WORM CONVEYOR OR INCINERATOR FOR CONSTANT EFFICIENCY OF THE AIR CHAFFS SEPARATION SYSTEM.
SUPPORTING FRAME IN TUBULAR PROFILES, STEEL MADE, TO CONTAIN AND SUPPORT THE OPERATING DEVICES, SO TO OBTAIN A COMPACT MACHINE-LIMITED ENCUMBRANCE, COMPLETE WITH PANELS FOR HEATING AND NOISE CONTAINMENT.
INDEPENDENT ELECTRIC CONTROL BOARD WITH PLC + TOUCH SCREEN AND ALL DEVICES FOR MACHINE CONTROL AND
MANAGEMENT, CAREFULLY WIRED AND EQUIPPED WITH ALL SIGNALS USEFULL FOR ROASTING PROCESS.STANDARD EQUIPMENT:
AUTOMATIC ROASTING SYSTEM MANAGED BY PLC + TOUCH SCREEN WITH RECORDING FOR ROASTING CURVES – PROFILES.
VISUALIZATION BY MONITOR OF TEMPERATURES AND ROASTING FUNTIONS.
FIRE PREVENTION EQUIPMENT ON THE ROASTING DRUM AND COOLING TANK; ON THE CYCLONE-CHAFFS SEPARATOR IF EQUIPPED WITH WORM CONVEYOR FOR CHAFFS EXTRACTION.
ALARM SYSTEM BY BUZZER AND SIGNAL LAMP, UPON INTERVENTION OF THE OVERLOAD PROTECTION DEVICES ON THE ELECTRIC-MOTORS AND ON THE BURNER.
PROTECTING SAFETY SYSTEMS.
CYCLONE FOR COOLING TANK: STANDARD ON MOD. 240-300- 360-480.
OPTIONALS EQUIPMENTCOMPUTERIZED AUTOMATIC ROASTING PROCESS CARP MANAGED BY PC AND MONITOR.
Learn More
HEATING RECOVERY SYSTE
SMOKE BURNER TYPE THERMICAL AND/OR CATALYST
CLEAN AIR ROASTING SYSTEM
CHAFFS COMPACTOR. -
K-8157 COAL FIRED POWER PLANT (2 X 50MW)K-8157 COAL FIRED POWER PLANT (2 X 50MW)
ENERGY BOILERS (CAE)
TURBINE SYSTEMS
STEAM TURBINES (TA) - DSL ARE 50 - 1
-CONDENSING TURBINE WITH TWO ADJUSTABLE OUTLETS, SUCH AS "ACTING" ON A SINGLE LINE OF TREES, DESIGNED TO DRIVE THE AC GENERATOR DIRECT-TYPE TH 60-2
-IS COMPOSED OF TWO BODIES: THE BODY OF HIGH PRESSURE (CIP) AND MEDIUM AND LOW PRESSURE BODY (CMP + CJP)
-HAS TWO ADJUSTABLE OUTLETS (PLUG SOCKETS AND PLUG HEATING) AND FIVE FIXED DOSES REGENERATIVE CIRCUIT FEEDSQUARES OF 600 CARS OVER T/H (WITH BUCKET WHEEL AND ARM LENGTH 12 M) - 4 PCS
-TIP HAMMER CRUSHERS CCA - 160 TO 2 PIECES
- RUBBER BANDS COAL TRANSPORTTHE MAIN EQUIPMENT IS ADDED TO ENSURE PROPER OPERATION FOLLOWING:
- SOLID FUEL STORAGE
- INSTALLATIONS AND INDUSTRIAL WATER SUPPLIES AND WASTEWATER DISCHARGE
- INSTALLATION OF EXHAUST HYDRAULIC SLAG
- WATER TREATMENT STATION
TO USE COAL, WEIGHT 88%, 12% NATURAL GASQUANTITY: 1
Learn More -
YY-2960 TM2500 & TM2500+ MOBILE GAS TURBINE GENERATORYY-2960 TM2500 & TM2500+ MOBILE GAS TURBINE GENERATOR TYPE OF FUEL: DUAL FUEL RUNNING TIME THAT THE TURBINE HAS MADE: LESS THAN 6000HRS Learn More