K-2577 BBC CONDENSING AND EXTRACTION STEAM TURBINE POWER PLANT 8.5MW YEAR 1975K-2577 BBC CONDENSING AND EXTRACTION STEAM TURBINE POWER PLANT 8.5MW YEAR 1975
8.5 MW
40 BAR
390 ˚ C
YEAR 1975QUANTITY: 1
Learn More -
C-4026 NUOVO PIGNONE GAS TURBINE, 11 MW AND CONDENSING TURBO GENERATOR SETS, 44.5 MW, YEAR 2002C-4026 NUOVO PIGNONE GAS TURBINE, 11 MW AND CONDENSING TURBO GENERATOR SETS, 44.5 MW, YEAR 2002
OFFER 001
11.7 MWE GAS TURBINE-GENERATOR SETS
GAS TURBINES
MANUFACTURER: NUOVO PIGNONE
MODEL: PGT10B-1
TYPE: MULTI-SHAFT, HEAVY DUTY GAS TURBINE
FUEL: NATURAL GASOFFER 002
ALTERNATOR
MANUFACTURER: ANSALDO
APPARENT POWER: 13,569 KVA
ACTIVE POWER: 11,000 KW
POWER FACTOR: 0.8
RATED SPEED: 1,500 RPMOFFER 003
65.7 TPH WASTE HEAT RECOVERY BOILERS
BOILERS
MANUFACTURER: MACCHI
THERMAL RATING: 55,330 KW
NET THERMAL EFFICIENCY. COP: 90.32%
NET THERMAL EFFICIENCY. COV: 92.48%OFFER 004
44.5 MW CONDENSING TURBO-GENERATOR SET
STEAM TURBINE
MANUFACTURER: NUOVO PIGNONE
MODEL NUMBER: HNK 50/3.2
CONFIGURATION: 1 IMPULSE STAGE 62 REACTION STAGES
RATED POWER: 44,500 KW
RATED INLET FLOW: 131,400 KG/HOFFER 005
GENERATOR
MANUFACTURER: JEUMONT INDUSTRIE
RATED APPARENT POWER: 51,500 KVA
POWER FACTOR: 0.8
ACTIVE POWER: 41,200 KWOFFER 006
CONDENSER
MANUFACTURER: CALDEMON
TYPE: SURFACE CONDENSERQUANTITY: 2
Learn More -
C-3994 BARGEMOUNTED POWER PLANT, CAPACITY 220MWC-3994 BARGEMOUNTED POWER PLANT, CAPACITY 220MW
A. ONCE THROUGH STEAM GENERATOR
B. BARGE
C. CHILLERS
D. AIR COMPRESSOR
E. GAS TURBINE
F. STEAM TURBINE
G. FEEDWATER SYSTEM
H. CLOSED COOLING WATER SYSTEM
I. AUXILIARY COOLING WATER SYSTEM
J. CONDENSATE POLISHING UNIT (CPU)
K. WASTE WATER SYSTEM
L. PLANT ELECTRICAL SYSTEM
M. BLACK START DG SET
N. PLANT CONTROLS AND INSTRUMENTATION
O. PLANT FIRE FIGHTING SYSTEM
P. START UP VACUUM SYSTEM
Q. STEAM TURBINE DEAERATING CONDENSERQUANTITY: 1 PLANT
Learn More -
TT-4465 AIR COOLED CHILLERS, CAPACITY 50 TO 500 TON, YEAR 2017 TO 2024, 60 HzTT-4465 AIR COOLED CHILLERS, CAPACITY 50 TO 500 TON, YEAR 2017 TO 2024, 60 Hz ITEM 001 YORK AIR COOLED CHILLERS CAPACITY: 50 TON QUANTITY: 2 ITEM 002 YORK AIR COOLED CHILLER CAPACITY: 70 TON QUANTITY: 1 ITEM 003 YORK AIR COOLED CHILLERS CAPACITY: 100 TON QUANTITY: 3 ITEM 004 YORK AIR COOLED CHILLER CAPACITY: 150 TON QUANTITY: 1 ITEM 005 YORK AIR COOLED CHILLER CAPACITY: 500 TON QUANTITY: 1 ITEM 006 TRANE AIR COOLED CHILLER QUANTITY: 2 Learn More -
KNITTING, DYEING, FINISHING MILL #1KNITTING, DYEING, FINISHING MILL #1 Learn More -
A-2611 ULTRAVIOLET AGING TESTING CHAMBER BOX TYPEA-2611 ULTRAVIOLET AGING TESTING CHAMBER BOX TYPE FLUORESCENT UV LAMP IS IMPORTED FOR THIS ACCELERATED AGING TEST CHAMBER. CAN SIMULATE HARM BY SUNLIGHT, RAINWATER AND DEW. UV WEATHER RESISTANCE CHAMBER USE FLUORESCENT UV LAMP TO SIMULATES THE EFFECT OF SUNLIGHT, CONDENSATION MOISTURE IS USED TO SIMULATE DEW. THE TESTED MATERIAL IS PLACED IN A LOOP PROGRAM THAT ALTERNATES LIGHT AND MOISTURE AT A CERTAIN TEMPERATURE. THE MATERIAL WAS TESTED FOR ACCELERATED WEATHERABILITY. UV CHAMBER CAN RE-CREATE HAZARDS THAT OCCUR OUTDOORS FOR MONTHS OR YEARS.THE TYPES OF HAZARDS INCLUDE: DISCOLORATION, CHALKINESS, POWDER LIGHT, CRACKING, TURBIDITY, BUBBLES, BRITTLE, STRENGTH, DECAY, OXIDATION, ETC. THIS MACHINE INCLUDES SPRAY DEVICE. Learn More -
V-1041 AIRLAY- FELT LINE 2400mmINDEX 1. Technical specification pag.2 2. Line composition pag.3 3. Machines description pag.4 4. Total price of the turn-key plant pag.25 5. Sale terms pag.26 6. Payment terms pag.28 7. General selling terms and conditions pag.29 Learn More -
TT-6947 SIEMENS STG STEAM TURBINE GENERATOR SET, 17.5 MW, YEAR 2005TT-6947 SIEMENS STG STEAM TURBINE GENERATOR SET, 17.5 MW, YEAR 2005 1. SIEMENS STG STEAM TURBINE GENERATOR SET 2. EXTRACTION-CONDENSING 3. CONDITION: USED 4. YEAR: 2005 5. BRAND: SIEMENS QUANTITY: 1 Learn More -
K-8157 COAL FIRED POWER PLANT (2 X 50MW)K-8157 COAL FIRED POWER PLANT (2 X 50MW)
ENERGY BOILERS (CAE)
TURBINE SYSTEMS
STEAM TURBINES (TA) - DSL ARE 50 - 1
-CONDENSING TURBINE WITH TWO ADJUSTABLE OUTLETS, SUCH AS "ACTING" ON A SINGLE LINE OF TREES, DESIGNED TO DRIVE THE AC GENERATOR DIRECT-TYPE TH 60-2
-IS COMPOSED OF TWO BODIES: THE BODY OF HIGH PRESSURE (CIP) AND MEDIUM AND LOW PRESSURE BODY (CMP + CJP)
-HAS TWO ADJUSTABLE OUTLETS (PLUG SOCKETS AND PLUG HEATING) AND FIVE FIXED DOSES REGENERATIVE CIRCUIT FEEDSQUARES OF 600 CARS OVER T/H (WITH BUCKET WHEEL AND ARM LENGTH 12 M) - 4 PCS
-TIP HAMMER CRUSHERS CCA - 160 TO 2 PIECES
- RUBBER BANDS COAL TRANSPORTTHE MAIN EQUIPMENT IS ADDED TO ENSURE PROPER OPERATION FOLLOWING:
- SOLID FUEL STORAGE
- INSTALLATIONS AND INDUSTRIAL WATER SUPPLIES AND WASTEWATER DISCHARGE
- INSTALLATION OF EXHAUST HYDRAULIC SLAG
- WATER TREATMENT STATION
TO USE COAL, WEIGHT 88%, 12% NATURAL GASQUANTITY: 1
Learn More -
M-4798 POWER PLANT 35,000KW YEAR 2008REFERENCE NUMBER: M-4798 (1111BBTLXX10) L POWER PLANT 35,000KW YEAR 2008 POWER PLANT, 35,000KW INCLUDES GENERAL ELECTRIC CONDENSING STEAM TURBINE BRUSH SYNCHRONOUS GENERATOR AIR COOLED CONDENSER SWITCHGEAR TRANSFORMERS CRANE & BUILDING YEAR 2008, UNUSED, 1 LOT QUANTITY AVAILABLE: 1 Learn More