Search results for: 'Rate p'
- Related search terms
- rate spindles
- Rate
- Rate pl
- Rate please
- rated capacity
-
TT-7161 MIURA LXH-300 GAS-FIRED STEAM BOILER, 300 HP, HIGH-PRESSURE, ENERGY-EFFICIENTTT-7161 MIURA LXH-300 GAS-FIRED STEAM BOILER, 300 HP, HIGH-PRESSURE, ENERGY-EFFICIENT 1. MIURA LX GAS FIRED STEAM BOILER, MODEL LXH-300. 2. HIGH-PRESSURE. 3. 300 HP CAPACITY. 4. RATED 30 PSI. QUANTITY: 1 Learn More -
YY-2311 GE TM2500+ GENERATION 6 GENERATOR PACKAGE – 26 MW EACH, 11,000 V, 50/60 Hz, DIESEL OR NATURAL GAS, YEAR 2011YY-2311 GE TM2500+ GENERATION 6 GENERATOR PACKAGE – 26 MW EACH, 11,000 V, 50/60 Hz, DIESEL OR NATURAL GAS, YEAR 2011 -AT 50 Hz THE UNITS ARE DESIGNED TO PRODUCE 26 MW OF POWER -AT 60 Hz THE UNITS ARE DESIGNED TO PRODUCE 30 MW OF POWER -DEPENDING ON LOCATION TEMPERATURE -THESE ARE CONTINUOUS POWER UNITS DETAILS: 1. 31MW CONTINUOUS RATED (GE ADVERTISED AT ISO CONDITIONS); 2. YEAR OF MANUFACTURE: 2011; 3. PACKAGE SN: 2011-TM006 AND 2011-TM008; 4. CURRENTLY CONFIGURED AS 11KV 50HZ, YET CAN OPERATE AT EITHER 50HZ OR 60HZ; 5. 2 UNITS AVAILABLE; 6. EQUIPMENT IS CONFIGURED TO OPERATE ON LIQUID FUEL OR NATURAL GAS; 7. CURRENT OPERATING HOURS AS OF JULY 30, 2022: TM006 – 1726 HOURS TM008 – 2174 HOURS; 8. HOURS REFLECT TOTAL TIME SINCE NEW: HOURS MAY GO UP AS UNITS ARE STILL CONNECTED FOR EMERGENCY USE ONLY. 9. PRICE INCLUDES THE GT1 REPAIRS RECOMMENDED BY GE IN THE ATTACHED INVESTIGATIVE REPORT; 10. HPT REPLACEMENT ON GT1 ONLY: - LEAD TIME FOR REPAIRS IS 12-14 WEEKS BASED ON CURRENT AVAILABILITY (SUBJECT TO CHANGE); - SCOPE OF SUPPLY FOR EACH UNIT IS LISTED IN APPENDIX A. Learn More -
TT-7849 JENBACHER JGS 620F GENERATOR SYSTEM, 6.712 MW TOTAL, 11KV, 20K/23K HOURS, NATURAL GAS, 2012TT-7849 JENBACHER JGS 620F GENERATOR SYSTEM, 6.712 MW TOTAL, 11KV, 20K/23K HOURS, NATURAL GAS, 2012 1. USED JENBACHER GENERATOR SYSTEM 2. CONSISTING OF (2) MODEL JGS 620F JENBACHER NATURAL GAS GENSETS 3. EACH RATED 3.356 MW; 2.9 MW NET OUTPUT; 1500 RPM; 3/50/11KV 4. YEAR BUILT 2012 5. REPORTED 20,000 HOURS AND 23,000 HOURS. CONTROLLED BY (1) PANEL. 6. BRAND: JENBACHER 7. MODEL: JGS 620F 8. USED EQUIPMENT FACTS ABOUT THIS MACHINE 9. FUEL TYPE: NATURAL GAS QUANTITY: 1 Learn More -
TT-6318 MWM GAS GENERATOR, 50 Hz, YEAR 2022 TO 2023 – GAS FUELTT-6318 MWM GAS GENERATOR, 50 Hz, YEAR 2022 TO 2023 – GAS FUEL AVAILABLE IMMEDIATELY Learn More -
TT-4735 SOLAR TURBINE TAURUS 60 – NEW, 5.67MW, YEAR 2019TT-4735 SOLAR TURBINE TAURUS 60 – NEW, 5.67MW, YEAR 2019 BRAND: SOLAR MODEL TAURUS 60 TYPE GAS TURBINES CONDITION NEW YEAR 2019 PACKAGE: BY SOLAR HOURS OF OPERATION: 0 FUEL CAPABILITY: NATURAL GAS/LIQUID COMBUSTION STANDARD: STANDARD BRAND KATO MODEL TAURUS 60 FREQUENCY 50Hz Learn More -
K-5175 AUTOMATIC PILLOW MACHINE WITH HOPPER FEEDREFERENCE NUMBER: K-5175 AUTOMATIC PILLOW MACHINE WITH HOPPER FEED DIMENSIONS: 11700mm X 4000mm X 3000mm POWER: 23.45KW CAPACITY: 8 TO 10 PIECES PER MINUTE LABOR NEED: 1 CONTROL SYSTEM: SIEMENS PLC ELECTRICITY: AS PER CUSTOMER FIBER OPENING RATE: 98%+ WEIGHT: 3650 KG QUANTITY AVAILABLE: 1 Learn More -
T-7966 SANFORIZER, NOMINAL WIDTH 2200mmT-7966 SANFORIZER, NOMINAL WIDTH 2200mm MACHINE HAND: LEFT OR RIGHT HAND WIDTH: 2200mm SPEED (M/MIN): 5~80M/MIN PRESHRINKAGE: 16%, VARIED FROM VARIETY SHRINKING RATE: ≤1% STEAM PRESSURE OF PRESS ROLLER: 0.5MPA DIAMETER OF DRYING CYLINDER OF FELT FINISH: Φ2000mm FELT: ABOUT 2200G/M2 WATER CONSUMPTION (TON /HR): 1 STEAM CONSUMPTION (KG/HR): 500 TRANSMISSION AND CONTROL: PLC CONTROL, PARAMETERS ON LINE DISPLAY IN COLOR TOUCH SCREEN, MULTI-UNIT AC FREQUENCY CONVERSION DRIVE INSTALLED POWER (KW): 38.45 OVERALL DIMENSION (L X W X H): 12010(L) X 4168(W) X 3925(H)mm QUANTITY: 1 SET Learn More -
M-1385 PILLOW FILLING MACHINEREFERENCE NUMBER: M-1385 (66032TYC5UF) PILLOW FILLING MACHINE PRODUCTION NAME PILLOW FILLING MACHINE ITEM NO. L001C VOLTAGE AS PER CUSTOMER POWER 22.05KW OPENER WIDTH 1000mm BALE BREAKER WIDTH 1200mm OPENER CAPACITY 400KG/H FILLING CAPACITY 8PCS/MIN UP FIBER OPENING RATE MAX.100% AIR PRESSURE 1M3/MIN; 0.8MPA CONTROL SYSTEM SIEMENS PLC PROGRAM DIMENSION 9824 x 2417 x 2400mm LABOR NEED 2 WEIGHT 3840KG QUANTITY AVAILABLE: 1 Learn More -
K-6063 AUTOMATIC PILLOW FILLING MACHINE SIEMENS PLCREFERENCE NUMBER: K-6063 AUTOMATIC PILLOW FILLING MACHINE SIEMENS PLC AUTOMATIC PILLOW MACHINE POWER: 23.45 KW CAPACITY: 6-8 PIECES/MIN CONTROL SYSTEM: SIEMENS PLC LABOR: 1 PERSON VOLTAGE: 380V, 50HZ, 3-PHASE FIBER OPENING RATE: 98% UP WEIGHT: 3650KG CONJUGATE HOLLOW SILICONIZED POLYESTER FIBER SHORTER THAN 100mm MICRO FIBER 0.6D-15D QUANTITY AVAILABLE: 1 Learn More -
TEMPERATURE AND HUMIDITY TEST CHAMBERREFERENCE NUMBER: Y-2076 TEMPERATURE AND HUMIDITY TEST CHAMBER THIS SERIES OF TEMPERATURE TEST CHAMBER IS SUITABLE FOR THE RELIABILITY TEST OF INDUSTRIAL PRODUCTS. IT HAS THE CHARACTERISTICS OF TEMPERATURE AND HUMIDITY CONTROL PRECISION AND WIDE CONTROL RANGE. ELECTRICAL AND ELECTRONIC PRODUCTS ENVIRONMENTAL TEST EQUIPMENT BASIC PARAMETERS VERIFICATION METHOD LOW TEMPERATURE, HIGH TEMPERATURE, CONSTAMP DAMP HEAT, ALTERNATING WET HEAT TEST EQUIPMENT REQUIREMENTS. SAMPLE REQUIREMENTS IN ORDER TO MAKE YOUR TEST DATA MORE REALISTIC AND EFFECTIVE, THE TEST CHAMBER SHOULD BE USED REASONABLY WHILE SATISFYING THE FOLLOWING PRINCIPLES. THE TOTAL MASS LOAD IS NOT MORE THAN 80 KG PER CUBIC METER OF CHAMBER VOLUME. THE TOTAL VOLUME OF THE LOAD IS NOT MORE THAN ⅕ OF THE WORKING CHAMBER VOLUME IN ANY SECTION PERPENDICULAR TO THE DOMINANT WIND DIRECTION, THE SUM OF THE LOAD AREAS SHOULD BE NO MORE THAN ⅓ OF THE CROSS-SECTIONAL AREA OF THE WORKING CHAMBER. DO NOT BLOCK THE FLOW OF AIRFLOW WHEN THE LOAD IS PLACED. VOLUME DIMENSION: ABOUT 150L INTERIOR SIZE: W: 600mm H: 600mm D: 460mm THE MAIN TECHNICAL PARAMETERS TEST CONDITION COOL METHOD: AIR COOLED MEASURED AT A ROOM TEMPERATURE OF + 25℃ UNDER NO LOAD, THE TEMPERATURE AND HUMIDITY PERFORMANCE TEST IS MEASURED ACCORDING TO THE RELEVANT REGULATIONS. THE SENSOR IS PLACED AT THE AIR OUTLET OF THE AIR HANDLING UNIT TEMPERATURE UNIT RANGE: 40 ℃ TO + 150 ℃ TEMPERATURE FLUCTUATION ± 0.5 ℃ TEMPERATURE UNIFORMITY: ≤ 2.0 ℃ TEMPERATURE DEVIATION: ≤ ± 2.0 ℃ TEMPERATURE CHANGE RATE HEAT UP RATE: - 40 ℃ TO +100 ℃ FULL RANGE AVERAGE SPEED: APPROX 45 MINUTES (NO LOAD) COOLING RATE: +20 ℃ TO 40 ℃ FULL RANGE AVERAGE SPEED: APPROX 60 MINUTES (NO LOAD) QUANTITY: 1 Learn More