REFERENCE NUMBER: A-2492
1000 L STABILITY CHAMBER
SPECIFICATIONS:
INNER CHAMBER SIZE: 1 X 1 X 1 mm
EXTERNAL DIMENSION: 1.2 X 1.97 X 2.17 mm
TEMPERATURE RANGE: 70 TO 180°C
HUMIDITY RANGE: 10% TO 98% RH, WHEN THE TEMPERATURE IS ABOVE 60°C, THE HUMIDITY CAN ACHIEVE 10% RH
TEMPERATURE & HUMIDITY FLUCTUATION: ±0.2℃, ±0.5% RH
INDICATION RESOLUTION: 0.01℃, 0.1% RH
TEMPERATURE & HUMIDITY UNIFORMITY: ±2℃, ±3% RH (TESTED WITH THE EMPTY CHAMBER, 30 MINUTES AFTER STABILIZATION)
HEAT UP AND COOL DOWN TIME: HEATING RATE: AVERAGE 3 ℃/MINUTES; COOLING RATE: AVERAGE 1 ℃/MINUTE (UNLOADED TEST)
MATERIAL: INNER CHAMBER: SUS#304 STAINLESS STEEL EXTERIOR STRUCTURE: STAINLESS STEEL PLATE + POWDER COATED
INSULATION: GLASS WOOL & PUF
PERSPIRATION RESISTANT: K STYLE TUBE
ACCESSORIES
• TEMPERATURE RESISTANT SILICONE GASKET: 1 PC
• CABLE PORT:1 PC; OD: 100 mm
• WINDOW LIGHT: 1 PC
• MULTIPANE VIEW WINDOW: 1 PC
• LOADING SHELVES: 2 PCS
REFRIGERATION & HEATING SYSTEM
• ORIGINAL IMPORTED HIGH EFFICIENCY COMPRESSOR
• AIR COOLING CONDENSER
• FIN – TUBE HEATER
• ORIGINAL IMPORTED SOLENOID VALVES
• INNER SPIRAL K – TYPE REFRIGERANT COPPER TUBE
• U – TYPE FINNED ELECTRO - THERMAL TUBE
• HEATING & COOLING SYSTEMS SEPARATED
• SINGLE STAGE REFRIGERATING SYSTEM
HUMIDIFYING & DEHUMIDIFYING SYSTEM
• ELECTRIC & BYTE TYPE HUMIDIFYING SYSTEM
• STAINLESS STEEL HUMIDIFYING BARREL WITH VIEW WINDOW FOR WATER LEVEL
• ADP DEHUMIDIFYING WAY
• OVER – TEMPERATURE AND OVERFLOW PROTECTION UNITS
• HUMIDIFYING & DEHUMIDIFYING SYSTEMS SEPARATED
CIRCLING & DRAIN SYSTEM
• CENTRIFUGAL FAN & IMPORTED MOTOR
• REVERSE UNIFLOW (AIR FLOW DIRECTION)
• FLOW – THROWS WIND
• DRAIN SYSTEM USES SWIRL TYPE OUTLET AND U – TRAP DEPOSITION UNIT
PROGRAMABLE MICRO COMPUTER LCD TOUCH CONTROLLER
• PROGRAMMABLE TOUCH CONTROLLER, USER - FRIENDLY, STABLE AND EASY USE
• PROGRAMS: 99 SEGMENTS PER PROGRAM, 120 PROGRAMS, 120 CYCLING PER PROGRAM
• PID & SSR CONTROL WAY, STABLE AND EASY USE
• HAVE SLOP CONTROL FUNCTION FOR HEATING & COOLING, LINKED PTNS CAN BE EXECUTED
• PID AUTOMATIC CALCULATION
• MICRO COMPUTER MULTI FUNCTION CONTROLLER, MAIN COMPONENTS ’DATA AUTOMATICALLY OUTPUT INCLUDING COMPRESSORS, SOLENOIDS, HEATING UNITS, ETC
• ERRORS OF MAIN COMPONENTS APPEAR ON THE LCD PANEL
• THE BRIGHTNESS OF THE LCD PANEL CAN BE ADJUSTED
• TIME SEQUENCE CONTROL INTERFACE RELAYS HAVE 3 GROUPS WHICH MANAGE THE OUTPUT OF OUTSIDE LOGIC UNITS INCLUDING SIGNAL, MECHANICAL AND POWER, ETC
• PROGRAMS AUTO – SAVE FUNCTION IF POWER CUT OFF SUDDENLY
• HAVE HOLD & ADV BUTTONS INPROGRAMS
• AUTOMATICALLY SET THE HIGH & LOW TEMPERATURE LIMITS AFTER PROGRAMS SET
• PASSWORD SET FUNCTION
• SD CARD SLOT, 2 GB SD CARD, RS232 OR ETHERNET (RJ45)
OPERATING ENVIRONMENT
• AMBIENT TEMPERATURE: +25℃ (2) RH ≤85%
PROTECTION
• ELECTRICITY LEAK PROTECTION
• LIGHTNING STRIKE PROTECTION, ZRN LIGHTNING ARRESTER INSIDE THE CONTROLLER
• SENSOR DATES TRANSFERRED INSIDE THE MICRO COMPUTER
• TEMP. SENSORS TO OPEN CIRCUIT OR SHORT CIRCUIT (+ - OVER)
• THE FIRST LEVEL OVER TEMPERATURE PROTECTION
• ERROR DETECTED UNITS
• THE SECOND LEVEL OVER TEMPERATURE PROTECTION TO ELECTRONIC OVER - TEMP PROTECTION UNIT
• THE THIRD LEVEL OVER - TEMPERATURE PROTECTION
• COMPRESSOR PROTECTION TO REFRIGERANTS PRESSURE PROTECTION & OVERLOAD PROTECTION.
• EXTENDED PROTECTION UNIT TO TWO SUPPLETIVE PORTS
• ERROR PROTECTION TO POWER CUT OFF, ERROR REPORTS SHOWN IN LCD PANEL AND AUDIBLE ALARM STARTS
• DYNAMIC HIGH AND LOW TEMPERATURE PROTECTION
• AMBIENT TEMPERATURE PROTECTION TO THE INNER CHAMBER AND SPECIMENS AUTOMATICALLY RETURN BACK TO AMBIENT TEMPERATURE AFTER THE OPERATION STOP SAFETY PROTECTION
• NON-FUSE PROTECTION SWITCH
• OVERHEAT ALARM PROTECTION
• COMPRESSOR OVERLOAD PROTECTION
• PHASE SEQUENCE PROTECTION
• MOTOR OVER TO CURRENT PROTECTION
Learn More
TT-7918 MAN HFO 18V32-40 GENERATING SETS - NEW, 50 Hz, 11 KV
1. MAN HFO 18V32-40 GENERATING SETS
2. NEW
3. MODEL 18V32-40
4. GROSS ELECTRICAL OUTPUT APPROX. 9,0 MW
5. DOUBLE FUEL
6. MAN DIESEL ENGINES 18V32/40, NEVER INSTALLED, MANUFACTURED AT MAN-GERMANY.
7. THE GROSS ELECTRICAL OUTPUT OF THIS PLANT IS APPROXIMATELY 9 MW EACH SPECIFIED AT THE GENERATOR TERMINALS.
8. THE OFFERED ENGINES ARE DESIGNED FOR FIRING BY GAS OR HFO/DIESEL. IN THIS OFFER THE AUXILIARY IS LISTED TOR 1 UNIT, SO THE DESCRIPTIONS REFER TO 1 UNIT ONLY. ALL ENGINES ARE EQUIPPED WITH BRAND NEW ABB GENERATORS BASED ON THE LIMITED INFORMATION AVAILABLE THE PRICE IS OF BUDGETARY NATURE.
9. PRICE IS BASED ON SEVERAL ASSUMPTIONS THAT NEED TO BE CONFIRMED/UPDATED BEFORE A FIRM CONTRACT OFFER CAN BE MADE.
QUANTITY: 12
Learn More
TT-6412 SOLAR TITAN 130 GAS TURBINE GENERATOR SET, YEAR 2012, 50/60 Hz
1. SOLAR TITAN T-130 GAS TURBINE GENERATION PACKAGE
2. BRAND SOLAR
3. YEAR 2012
4. 60 Hz (CAN CONVERT TO 50 Hz)
QUANTITY: 1
Learn More