Search results for: 'm-5'
-
TT-7913 SIEMENS SST-300 COMPLETE STEAM POWER GENERATOR, 20.29 MW, YEAR 2021, 50HzTT-7913 SIEMENS SST-300 COMPLETE STEAM POWER GENERATOR, 20.29 MW, YEAR 2021, 50Hz 1. UNPACKED - STILL BOXED AND CRATED - COMPLETE PLANT 2. NEW UNUSED 3. MODEL: SIEMENS SST-300 4. YEAR OF MANUFACTURE: 2021 Learn More -
TT-6368 CUMMINS QSK60G8 POWER GENERATION, 1800KW, YEAR 2012, 50/60HzTT-6368 CUMMINS QSK60G8 POWER GENERATION, 1800KW, YEAR 2012, 50/60Hz 1. CUMMINS QSK60G8 POWER GENERATION 2. YEAR: 2012 3. DIESEL OIL (FUEL) QUANTITY: 9 Learn More -
ALSTOM GAS POWER PLANT, 252 MWREFERENCE NUMBER: T-6937 ALSTOM GAS POWER PLANT, 252 MW ALSTOM GAS POWER PLANT 252 MW WITH SIEMENS TECHNOLOGY STILL INSTALLED, USED ONLY TEST AND MAINTENANCE OPERATION 500 HOURS QUANTITY: 1 Learn More -
L-5951 WESTINGHOUSE 100 MW GAS TURBINES, LNG FIRED, 60 Hz, YEAR 1995REFERENCE NUMBER: L-5951
WESTINGHOUSE 100 MW GAS TURBINES, LNG FIRED, 60 Hz, YEAR 1995
GAS TURBINES
MAKE: WESTINGHOUSE
YEAR: 1995 (STOPPED IN JUNE 2013)
100 MW EACH X 6 = 600 MW TOTAL
QUANTITY: 5
Learn More -
K-8156 SIEMENS SCHUCKERTWERKE AG COAL FIRED POWER PLANT 120 MW YEAR 1967K-8156 SIEMENS SCHUCKERTWERKE AG COAL FIRED POWER PLANT 120 MW YEAR 1967
COAL FIRED POWER PLANT, 120 MW
MANUFACTURER: SIEMENS - SCHUCKERTWERKE AG
TYPE: CONDENSING - EXTRACTION
FUEL: COAL
SPEED: 3000 U/MIN
POWER: MINIMUM: 125 MW
MAXIMUM: 140 MW
PRESSURE: 185 BAR
TEMPERATURE: 530°C
FREQUENCY: 48.5 - 51.5 HZ
YEAR: 1967
BOILER: BABCOCKSCOPE OF SUPPLY:
-REA AND DENOS (LOW NOx AND SULFUR), INCLUDING SCR-CATALYSATOR AND ELECTROFILTER
-TURBINE
0BOILER
-COAL CRASHER
-COAL BUNKER/STORAGE/TRANSPORTATION
-CONDENSER
-PUMPS AND PIPING
-WATERDEMIRALISTAION
-CHIMNEY
-COOLING SYSTEM AND COOLERS
-LUBRICATION OIL
-COMPRESSOR AIR
-FRESH AIR SYSTEM
-CRANAGE
-ENGINE AND PLANT PLC, MANUFACTURER SIEMENS
-HIGH VOLTAGE
-TRANSFORMER
-ELECTRICAL BOXES AND SWITCHESQUANTITY: 1
Learn More -
K-8046 BBC-ABB 300 MW COAL-OIL-GAS BIOMASS FIRED PLANT YEAR 2006K-8046 BBC-ABB 300 MW COAL-OIL-GAS BIOMASS FIRED PLANT YEAR 2006
COAL FIRED STEAM TURBINE POWER PLANT
300MW
COAL OIL GAS
BIOMASS FIRED
OUTPUT: 600 MW
180 BAR
540°C
MANUFCATURER/TYPE: BBC-ABB
YEAR: 2006
ONLY 13,300 AND 45,000 RUNNING HOURS AFTER MAJOR OVERHAULALTERNATOR ACEC TC 1498
COOLING: HYDROGEN 22 KV 3000 TR 1550 KVA
MAIN TRAFO: WESTINGHOUSE 375 MVA 156/22 KV
COUPLE TRAFO: ALSTHOM 20 MVA 22/6.4 KV
START TRAFO: ALSTHOM 20 MVA 71.5/6.4 KVFUELPUMPS: ID:3 / HD:3 LD:2881/HD:2223
16 BURNERS TANGENIALGASBURNERS: TANGENIAL 16 PCS 5000 NM3
COAL GRINDING MILLS:
(4) LOESCHE LM 19.20D
25 T/HR(2) LOESCHE LM 20.20D
35 T/HRBIOMASS POWER GENERATION BY CFB (CIRCULATING FLUIDIZED BED) BOILER 20 MWe FIRED BY WOOD DERIVED WASTES CUT INTO CHIPS. COMPLETE SAWDUST INSTALLATION.
UNIT 1
172,000 HOURS, OVERHAULED IN 2006
NEW ROTOR (HD, MD, LD)
ONLY 13,000 HOURS AFTER OVERHAUL
IN PRODUCTION UNTIL JANUARY 5, 2013
SWAP HD ROTOR IN APRIL 2011 ONLY 408 HOURS UNTIL NOW!UNIT 2
265,000 HOURS, OVERHAULED IN 2006 (HD, MD, LD)
45,000 HOURS AFTER OVERHAUL
IN PRODUCTION UNTIL JANUARY 5, 2013
SWAP HD ROTOR IN NOVEMBER 2011 ONLY 13,300 HOURS UNTIL NOW!
189 KG/CM2, 540˚C, 3000 T/MINPLANT ORIGINALLY FROM THW 1970’S BUT RENEWED IN 2006
STILL INSTALLED
IMMEDIATE DISMANTLING POSSIBLE
BOILER INTAKE CAPACITY: 3500 T/H
NEW PLCQUANTITY: 2
Learn More -
K-2572 SIEMENS COAL FIRED POWER PLANT 120MW YEAR 1967K-2572 SIEMENS COAL FIRED POWER PLANT 120MW YEAR 1967
120 MW
185 BAR
530 ˚ C
YEAR 1967
GOOD CONDITIONQUANTITY: 1
Learn More -
K-2571 MAN COAL FIRED POWER PLANT 330MW YEAR 1983K-2571 MAN COAL FIRED POWER PLANT 330MW YEAR 1983
330 MW
178 BAR
535 ˚ C
YEAR 1983
GOOD CONDITIONQUANTITY: 1
Learn More -
K-2567 JENBACHER LANDFIL GAS AND NATURAL GAS ENGINE 0.527MW YEAR 2012 TO 2013K-2567 JENBACHER LANDFIL GAS AND NATURAL GAS ENGINE 0.527MW YEAR 2012 TO 2013
0.527MW
YEAR 2012-2013- NEW, 2 YEARS WARRANTY
TYPE: JMS 312 GS-BL
50HZ
CHP MODULE
HEAT EXCHANGER
OIL TANK
DIANE XT PLC
LANDFILL GAS LINE
SPARESQUANTITY: 2
Learn More -
K-2563 JENBACHER GAS ENGINES 1.64MW YEAR 1995K-2563 JENBACHER GAS ENGINES 1.64MW YEAR 1995
TYPE: JENBACHER JMS 616GS-NLC
FUEL: NATURAL GAS
1.64MW PLUS 2MW THERM. EACH
3 TRANFORMERS
3 HEAT EXCHANGERS
ELECTRIC
50 HZ
CONDITION: BETWEEN 45000 - 50000 RUNNING HOURS
FREQUENCY/COS PHI: 50 HZ / 0.8
ALTERNATOR VOLTAGE: 6.3
WITH ALL FULL
SERVICE REPORTS FROM THE MANUFACTURER
EXCELLENT CONDITIONQUANTITY: 3
Learn More