Search results for: 'Gas gen'
- C-2575 WARTSILA GENERATORS, YEAR 1994 TO 2012
C-2575 WARTSILA GENERATORS, YEAR 1994 TO 2012
ITEM 001
WARTSILA W 20V
MODEL: W 20V
OUTPUT (MW): 8.8
NATURAL GAS
COMPLETE POWER PLANT
11 KV
INCL. 4
STEAM BOILERS WITH 13 BAR
AND 4.7 T/H COOLERS
TRANSFORMERS
50 HZ
34 SG
YEAR: 2005
RUNNING HOURS: 50000
GOOD CONDITIONQUANTITY: 4
ITEM 002
WARTSILA W20
MODEL: W20
OUTPUT (MW): 8.7
DUAL FUEL ENGINES
50 HZ
V34 DF
YEAR: 2012
RUNNING HOURS: ZERO
NEWQUANTITY: 6
ITEM 003
WARTSILA 8L32
MODEL: 8L32
OUTPUT (MW): 3.84
HFO ENGINE
YEAR: 2009
RUNNING HOURS: ZEROQUANTITY: 6
ITEM 004
WARTSILA 33V16S6D
MODEL: 33V16S6D
OUTPUT (MW): 2
DIESEL ENGINE
50 HZ
YEAR: 1994
RUNNING HOURS: 7597QUANTITY: 1
ITEM 005
WARTSILA SACM SDRG 150 V12 S4D
MODEL: SACM SDRG 150 V12 S4D
OUTPUT (MW): 0.53
DIESEL ENGINE
50 HZ
YEAR: 1996
RUNNING HOURS: 560QUANTITY: 1
Learn More - K-8046 BBC-ABB 300 MW COAL-OIL-GAS BIOMASS FIRED PLANT YEAR 2006
K-8046 BBC-ABB 300 MW COAL-OIL-GAS BIOMASS FIRED PLANT YEAR 2006
COAL FIRED STEAM TURBINE POWER PLANT
300MW
COAL OIL GAS
BIOMASS FIRED
OUTPUT: 600 MW
180 BAR
540°C
MANUFCATURER/TYPE: BBC-ABB
YEAR: 2006
ONLY 13,300 AND 45,000 RUNNING HOURS AFTER MAJOR OVERHAULALTERNATOR ACEC TC 1498
COOLING: HYDROGEN 22 KV 3000 TR 1550 KVA
MAIN TRAFO: WESTINGHOUSE 375 MVA 156/22 KV
COUPLE TRAFO: ALSTHOM 20 MVA 22/6.4 KV
START TRAFO: ALSTHOM 20 MVA 71.5/6.4 KVFUELPUMPS: ID:3 / HD:3 LD:2881/HD:2223
16 BURNERS TANGENIALGASBURNERS: TANGENIAL 16 PCS 5000 NM3
COAL GRINDING MILLS:
(4) LOESCHE LM 19.20D
25 T/HR(2) LOESCHE LM 20.20D
35 T/HRBIOMASS POWER GENERATION BY CFB (CIRCULATING FLUIDIZED BED) BOILER 20 MWe FIRED BY WOOD DERIVED WASTES CUT INTO CHIPS. COMPLETE SAWDUST INSTALLATION.
UNIT 1
172,000 HOURS, OVERHAULED IN 2006
NEW ROTOR (HD, MD, LD)
ONLY 13,000 HOURS AFTER OVERHAUL
IN PRODUCTION UNTIL JANUARY 5, 2013
SWAP HD ROTOR IN APRIL 2011 ONLY 408 HOURS UNTIL NOW!UNIT 2
265,000 HOURS, OVERHAULED IN 2006 (HD, MD, LD)
45,000 HOURS AFTER OVERHAUL
IN PRODUCTION UNTIL JANUARY 5, 2013
SWAP HD ROTOR IN NOVEMBER 2011 ONLY 13,300 HOURS UNTIL NOW!
189 KG/CM2, 540˚C, 3000 T/MINPLANT ORIGINALLY FROM THW 1970’S BUT RENEWED IN 2006
STILL INSTALLED
IMMEDIATE DISMANTLING POSSIBLE
BOILER INTAKE CAPACITY: 3500 T/H
NEW PLCQUANTITY: 2
Learn More - C-3990 HYUNDAI HIMSEN 9H25/33 HFO POWER PLANT, CAPACITY 10.5 MW, YEAR 2014 - NEW
C-3990 HYUNDAI HIMSEN 9H25/33 HFO POWER PLANT, CAPACITY 10.5 MW, YEAR 2014 - NEW
MAKE/MODEL: HYUNDAI HIMSEN 9H25/33
HFO POWER PLANT
CAPACITY: 10.5 MW
WATTAGE: 46,200 KW
YEAR: 2014
HOURS: NEW
FUEL TYPE: HFO
FREQUENCY: 50 HZ
ENCLOSURE: SOUND ATTENUATED ENCLOSURE
MANUFACTURER: HHI
ENGINE MODEL: HYUNDAI HIMSEN 9H25/33
GENERATOR MODEL: HYUNDAI
FOR 50HZ: 2100KW, 6000V, 750 RPMQUANTITY: 5
Learn More