Search results for: 'Cooling'
- Related search terms
- Cooling ta
- Cooling table
- cooling tunnel
-
TT-7861 TAURUS 65 GAS TURBINE GENERATOR SET, YEAR 2022, WITH ONLY 300 HOURSTT-7861 TAURUS 65 GAS TURBINE GENERATOR SET, YEAR 2022, WITH ONLY 300 HOURS 1. WITH ONLY 300 HOURS 2. TAURUS 65 3. 300 HOURS 4. YEAR 2022 5. THE DISMANTLED AND READY FOR DELIVERY 6. TAURUS 65 GAS TURBINE 7. INDUSTRIAL, SINGLE-SHAFT 8. 13 STAGE COMPRESSOR 9. VARIABLE INLET GUIDE VANES AND STATORS QUANTITY: 1 Learn More -
Y-3210 RED LINE "WLS -GIMBEL SYSTEM" FOR MAXIMUM OUTPUTS 2000 TO 3800 KG PER HOUR, WORKING WIDTH 460mmYY-3210 RED LINE "WLS -GIMBEL SYSTEM" FOR MAXIMUM OUTPUTS 2000 TO 3800 KG PER HOUR, WORKING WIDTH 460mm WLS ROLLING & SCORING THE RED LINE "WLS -GIMBEL SYSTEM" FOR MAXIMUM OUTPUTS: 2000 TO 3800 KG/HR. FEATURES: - CONDITION: REFURBISHED - MANUFACTURER: WLS - USAGE: CHEWING GUM FORMING LINE - CAPACITY: 2.000 KG/HR. - WORKING WIDTH: 460mm - PIECES’ DIMENSIONS: ACCORDING TO THE CUSTOMERS NEED Learn More -
TT-4161 CROWN AC HIGH HEAT EXTRUDER - SINGLE SCREW, 2.5”, 36:1, 75HP, YEAR 2015TT-4161 CROWN AC HIGH HEAT EXTRUDER - SINGLE SCREW, 2.5”, 36:1, 75HP, YEAR 2015 TYPE: EXTRUDERS - SINGLE SCREW CATEGORY: EXTRUDERS BRAND: CROWN MODEL: 2.5 36:1 LD YEAR: 2015 EXCELLENT CONDITION Learn More -
TT-2916 CROWN 2.5” 36:1 75HP HIGH HEAT, SINGLE SCREW, YEAR 2015TT-2916 CROWN 2.5” 36:1 75HP HIGH HEAT, SINGLE SCREW, YEAR 2015 CROWN 2.5” SINGLE SCREW EXTRUDER OVERVIEW TYPE: EXTRUDERS - SINGLE SCREW CATEGORY: EXTRUDERS BRAND: CROWN MODEL: 2.5 36:1 LD YEAR: 2015 EXCELLENT CONDITION QUANTITY: 1 Learn More -
TT-2177 GAS BASED COMBINED CYCLE POWER PLANT, 116 MW, YEAR 2021TT-2177 GAS BASED COMBINED CYCLE POWER PLANT, 116 MW, YEAR 2021 GENERAL ELECTRIC GAS TURBINE GAS TURBINE MODEL NUMBER: GE, 6FAG QUANTITY: 1 Learn More -
TT-2153 SIEMENS SGT-800 GAS TURBINE, 54 MW, 11 KV, 50 Hz AND 1500 RPM, FUEL NATURAL GAS, FREQUENCY 50/60 HzTT-2153 SIEMENS SGT-800 GAS TURBINE, 54 MW, 11 KV, 50 Hz AND 1500 RPM, FUEL NATURAL GAS, FREQUENCY 50/60 Hz GROSS EFFICIENCY 38.86.0% HEAT RATE9, 256 KJ/KWH UNUSED CONDITION: EXCELLENT (NEW SURPLUS) TURBINES STORED TO SIEMENS RECOMMENDATION. NOTE: THIS IS A PACKAGE DEAL AND REQUIRES BUYER TO PURCHASE ALL 3 UNITS. POI AND POF REQUIRED UPFRONT. QUANTITY: 3 Learn More -
1000 L STABILITY CHAMBERREFERENCE NUMBER: A-2492 1000 L STABILITY CHAMBER SPECIFICATIONS: INNER CHAMBER SIZE: 1 X 1 X 1 mm EXTERNAL DIMENSION: 1.2 X 1.97 X 2.17 mm TEMPERATURE RANGE: 70 TO 180°C HUMIDITY RANGE: 10% TO 98% RH, WHEN THE TEMPERATURE IS ABOVE 60°C, THE HUMIDITY CAN ACHIEVE 10% RH TEMPERATURE & HUMIDITY FLUCTUATION: ±0.2℃, ±0.5% RH INDICATION RESOLUTION: 0.01℃, 0.1% RH TEMPERATURE & HUMIDITY UNIFORMITY: ±2℃, ±3% RH (TESTED WITH THE EMPTY CHAMBER, 30 MINUTES AFTER STABILIZATION) HEAT UP AND COOL DOWN TIME: HEATING RATE: AVERAGE 3 ℃/MINUTES; COOLING RATE: AVERAGE 1 ℃/MINUTE (UNLOADED TEST) MATERIAL: INNER CHAMBER: SUS#304 STAINLESS STEEL EXTERIOR STRUCTURE: STAINLESS STEEL PLATE + POWDER COATED INSULATION: GLASS WOOL & PUF PERSPIRATION RESISTANT: K STYLE TUBE ACCESSORIES • TEMPERATURE RESISTANT SILICONE GASKET: 1 PC • CABLE PORT:1 PC; OD: 100 mm • WINDOW LIGHT: 1 PC • MULTIPANE VIEW WINDOW: 1 PC • LOADING SHELVES: 2 PCS REFRIGERATION & HEATING SYSTEM • ORIGINAL IMPORTED HIGH EFFICIENCY COMPRESSOR • AIR COOLING CONDENSER • FIN – TUBE HEATER • ORIGINAL IMPORTED SOLENOID VALVES • INNER SPIRAL K – TYPE REFRIGERANT COPPER TUBE • U – TYPE FINNED ELECTRO - THERMAL TUBE • HEATING & COOLING SYSTEMS SEPARATED • SINGLE STAGE REFRIGERATING SYSTEM HUMIDIFYING & DEHUMIDIFYING SYSTEM • ELECTRIC & BYTE TYPE HUMIDIFYING SYSTEM • STAINLESS STEEL HUMIDIFYING BARREL WITH VIEW WINDOW FOR WATER LEVEL • ADP DEHUMIDIFYING WAY • OVER – TEMPERATURE AND OVERFLOW PROTECTION UNITS • HUMIDIFYING & DEHUMIDIFYING SYSTEMS SEPARATED CIRCLING & DRAIN SYSTEM • CENTRIFUGAL FAN & IMPORTED MOTOR • REVERSE UNIFLOW (AIR FLOW DIRECTION) • FLOW – THROWS WIND • DRAIN SYSTEM USES SWIRL TYPE OUTLET AND U – TRAP DEPOSITION UNIT PROGRAMABLE MICRO COMPUTER LCD TOUCH CONTROLLER • PROGRAMMABLE TOUCH CONTROLLER, USER - FRIENDLY, STABLE AND EASY USE • PROGRAMS: 99 SEGMENTS PER PROGRAM, 120 PROGRAMS, 120 CYCLING PER PROGRAM • PID & SSR CONTROL WAY, STABLE AND EASY USE • HAVE SLOP CONTROL FUNCTION FOR HEATING & COOLING, LINKED PTNS CAN BE EXECUTED • PID AUTOMATIC CALCULATION • MICRO COMPUTER MULTI FUNCTION CONTROLLER, MAIN COMPONENTS ’DATA AUTOMATICALLY OUTPUT INCLUDING COMPRESSORS, SOLENOIDS, HEATING UNITS, ETC • ERRORS OF MAIN COMPONENTS APPEAR ON THE LCD PANEL • THE BRIGHTNESS OF THE LCD PANEL CAN BE ADJUSTED • TIME SEQUENCE CONTROL INTERFACE RELAYS HAVE 3 GROUPS WHICH MANAGE THE OUTPUT OF OUTSIDE LOGIC UNITS INCLUDING SIGNAL, MECHANICAL AND POWER, ETC • PROGRAMS AUTO – SAVE FUNCTION IF POWER CUT OFF SUDDENLY • HAVE HOLD & ADV BUTTONS INPROGRAMS • AUTOMATICALLY SET THE HIGH & LOW TEMPERATURE LIMITS AFTER PROGRAMS SET • PASSWORD SET FUNCTION • SD CARD SLOT, 2 GB SD CARD, RS232 OR ETHERNET (RJ45) OPERATING ENVIRONMENT • AMBIENT TEMPERATURE: +25℃ (2) RH ≤85% PROTECTION • ELECTRICITY LEAK PROTECTION • LIGHTNING STRIKE PROTECTION, ZRN LIGHTNING ARRESTER INSIDE THE CONTROLLER • SENSOR DATES TRANSFERRED INSIDE THE MICRO COMPUTER • TEMP. SENSORS TO OPEN CIRCUIT OR SHORT CIRCUIT (+ - OVER) • THE FIRST LEVEL OVER TEMPERATURE PROTECTION • ERROR DETECTED UNITS • THE SECOND LEVEL OVER TEMPERATURE PROTECTION TO ELECTRONIC OVER - TEMP PROTECTION UNIT • THE THIRD LEVEL OVER - TEMPERATURE PROTECTION • COMPRESSOR PROTECTION TO REFRIGERANTS PRESSURE PROTECTION & OVERLOAD PROTECTION. • EXTENDED PROTECTION UNIT TO TWO SUPPLETIVE PORTS • ERROR PROTECTION TO POWER CUT OFF, ERROR REPORTS SHOWN IN LCD PANEL AND AUDIBLE ALARM STARTS • DYNAMIC HIGH AND LOW TEMPERATURE PROTECTION • AMBIENT TEMPERATURE PROTECTION TO THE INNER CHAMBER AND SPECIMENS AUTOMATICALLY RETURN BACK TO AMBIENT TEMPERATURE AFTER THE OPERATION STOP SAFETY PROTECTION • NON-FUSE PROTECTION SWITCH • OVERHEAT ALARM PROTECTION • COMPRESSOR OVERLOAD PROTECTION • PHASE SEQUENCE PROTECTION • MOTOR OVER TO CURRENT PROTECTION Learn More -
L-3886 CHICKEN FEED PRODUCTION LINEREFERENCE NUMBER: L-3886
Learn More
1) RECEIVING PROCESS
HEIGHT: 12 METERS
POWER: 1.5 KW
2) GRINDING AND MIXING PROCESS
LENGTH: 1.5 METERS
POWER: 1.5 KW
3) PELLETIZING AND BAGGING PROCESS
CAPACITY: 2 TO 3 TONS PER HOUR, PER UNIT
POWER: 37 KW
4) AUXILIARY PROCESS
POWE: 1.5 KW
5) ELECTRIC CONTROL SYSTEM
POWER: 3 PHASE, 380 VOLTS, 50 Hz -
R-6855 STA IMPIANTI MILLENNIUM 3 ROASTING MACHINESR-6855 STA IMPIANTI MILLENNIUM 3 ROASTING MACHINES
THE ROASTING MACHINES SERIES MILLENNIUM 3 REALIZED BY STA IMPIANTI SRL CONFIRM THEMSELVES CAPABLES OF A WORLD LEADING TRADE MARK IN DESIGN AND PROJECTATION OF INDUSTRIAL AUTOMATIC ROASTING MACHINES FOR COFFEE AND OTHER SIMILAR PRODUCTS. THESE MACHINES, ALLOWING HIGHLY INTEGRATED TECHNOLOGICAL SOLUTIONS, ANTICIPATE THE MOST ADVANCED MARKET DEMANDS.
THANKS TO THE CONSTANT PURSUIT OF HIGH QUALITY STANDARD AND THE COMPANY’S DESIRE TO PROVIDE AT THE SAME TIME A PRODUCT TAILORED TO THE NEEDS OF EACH CLIENT COMPANY, STA IMPIANTI SRL IS ABLE TO OFFER THE BEST SOLUTION IN THE MARKET.THE ROASTING MACHINES SERIES MILLENNIUM 3 ARE GUARANTEE OF THE HIGHEST STANDARDS OF TECHNOLOGY DECLINED
ON CONCEPS OF HIGH PRODUCTION, MAXIMUM PERFORMANCE, RELIABILITY TOTAL SAFETY WITH LOW NOISE AND ENVIRONMENTAL EMISSIONS.
STANDARD EQUIPMENT:
ELECTRIC CONTROL BOARD WITH PLC + TOUCH SCREEN FOR FULL AUTOMATIC OR PARTIAL DRIVE.
AUTOMATIC ROASTING PROCESS WITH RECORDING – STORAGE OF ROASTING PARAMETERS
SYSTEM CONTROL THROUGH PLC + TOUCH SCREEN
FITTINGS FOR PC
ALARM SYSTEM BY BUZZER AND SIGNAL LAMP WITH DISPLAY ANOMALIES.
PRE-HEATING SYSTEM FOR RAW COFFEE IN STAND-BY
TEMPERATURE COFFEE CONTROL BOTH DURING ROASTING AND COOLING CYCLE.
HOT AIR GENERATOR (STA IMPIANTI‘ PATENTED SYSTEM)
“LOW INERTIA” DEVICE FOR IMMEDIATE STARTING OF PRODUCTION
INDUSTRIAL GAS BURNER TYPE MODULATING OR GASOIL BURNER AT MULTI STAGES OF FLAME ACCORDING APPLICATION.
PROCESS AIR ADMITTANCE CONTROL SYSTEM
FITTINGS FOR CLEAN AIR BY AIR EXCHANGER
CONTROL BOARD COMPLETE WITH LIGHTING DEVICE
SCREENER WITH PNEUMATIC DRAWING
WATER PUMP COMPLETE WITH TANK AND SAFETY BY PASS DEVICE
PRE COOLING SYSTEM OVER ROASTING DRUM
PRE COOLING SYSTEM CONNECTED TO THE COOLER
FIRE PREVENTION SYSTEM LINKED TO THE CYCLONE-CHAFFS COLLECTOR.
CYCLONE-CHAFFS COLLECTOR WITH DRIVEN STAR VALVE
CYCLONE FOR COOLER AND DESTONER
SELF CLEANING COOLING TANK
ADDITIONAL EMERGENCY UNLOADING FOR COOLER
INTEGRATED DESTONER
SERVOCONTROL DEVICE FOR REMOTE ADJUSTMENT OF DESTONER
SOUND PROOFING SYSTEM
GLOBAL SAFETY PROTECTION
OPTIONAL EQUIPMENTCOMPUTERIZED AUTOMATIC ROASTING PROCESS CARP MANAGED BY PC AND MONITOR.
CLEAN AIR BY AIR GENERATOR-EXCHANGING SYSTEM
POST COMBUSTOR TYPE THERMAL BURNER OR CATALYTIC
EXTERNAL DRAWING AIR (QUICK FRESH) SYSTEM
DESTONER WEIGHING CELLS
CHAFFS COMPACTOR.
HEATING ADDUCTION SYSTEM:PATENTED SYSTEM BY STA IMPIANTI SRL SPECIFICALLY STUDIED FOR ROASTING LINE APPLICATIONS. THIS SYSTEM ALLOWS SHORTER AND HOMOGENEOUS ROASTING TIME:
BY CONVECTION HOT AIR FLOWING THROUGH THE COFFEE IN THE DRUM
BY CONDUCTION DUE TO THE HEATED ROASTING DRUM
BY IRRADIANCE FROM THE GRATE LOCATED BETWEEN THE FLAME AND THE ROASTING DRUM (INFRARED RAYS)
HOT AIR GENERATOR:THREE ARE THE POSSIBILITIES OF SETTLEMENT TO THE OVER INDICATED SYSTEM:
AIR BY AIR EXCHANGING SYSTEM WITH RECOVERY DEVICE (100% CLEAN AIR)
Learn More
CONVENTIONAL GENERATOR
HEATING GENERATOR WITH PARTIAL OR TOTAL RECYCLE -
P-5096 STA ROASTING SYSTEM MILLENIUM 3 240 KILOSP-5096 STA ROASTING SYSTEM MILLENIUM 3 240 KILOS
ABSOLUTE RESPECT OF THE COFFEE, BIG PERFORMANCE IN REDUCED SPACES WITH MOST HOT AIR THROUGH THE BEANS OF A DRUM BATCHING SYSTEM. 10 YEARS OF VERY EXCITING RESEARCH HAS GONE INTO THIS LINE OF MACHINES. MILLENNIUM CONCENTRATES TECNOLOGY INNOVATION IN THE RESPECT OF THE PRODUCT QUALITY WHICH HAS NEVER BEEN REALISED BEFORE. WE GIVE VALUE TO YOUR PRODUCT WHILE MAKING YOUR JOB SIMPLER.
TECHNICAL DATA:
CONTROL BOARD WITH PARTIAL OR FULL AUTOMATIC DRIVE.
COMPUTERIZED AUTOMATIC ROASTING PROCESS WITH RECORDING SYSTEM.
CONTROL THROUGH PLC. FITTING FOR PC
ALARM SYSTEM BY BUZZER AND SIGNAL LAMP WITH DISPLAY ANOMALIES
PRE-HEATING SYSTEM FOR RAW COFFEE IN STAND-BY
TEMPERATURE COFFEE CONTROL BOTH DURING ROASTING AND COOLING CYCLE
HOT AIR GENERATOR (STA IMPIANTI PATENTED SYSTEM).
"LOW INERTIA" DEVICE FOR IMMEDIATE STARTING OF PRODUCTION.
INDUSTRIAL BURNER WITH 3 LEVELS (VARIABLES) AT IMMEDIATE ANSWER
PROCESS AIR ADMITTANCE CONTROL SYSTEM.
FITTING FOR CLEANED AIR TO AIR EXCHANGER
CONTROL BOARD COMPLETE WITH LIGHTING DEVICE.
SCREENER WITH AUTOMATIC DRAWING.
WATER PUMP COMPLETE WITH TANK AND SAFETY “BY PASS” DEVICE.
PRE-COOLING SYSTEM CONNECTED TO THE ROASTING DRUM.
PRE-COOLING SYSTEM CONNECTED TO THE COOLER.
FIRE PREVENTION SYSTEM LINKED TO THE CHAFF COLLECTOR.
CYCLON FOR COOLER AND DESTONER.
SELF-CLEANING COOLING CONTAINER.
ADDITIONAL EMERGENCY DISCHARGE FOR COOLER.
INTEGRATED DESTONER.
SERVOCONTROL DEVICE FOR REMOTE ADJUSTMENT OF DESTONER.
SOUND PROOFING SYSTEM
GLOBAL SAFETY PROTECTIONQUANTITY: 1
Learn More