Search results for: 'Operating sy'
- Related search terms
- Operating
- Operating sy'A=0
- Operating sy'A=0'
- operating sy'[0]
- operating sima 0
- TT-1355 SPRAY DRYER, CAPACITY OF EVAPORATION 50L/HTT-1355 SPRAY DRYER, CAPACITY OF EVAPORATION 50L/H SPRAY DRYER CAPACITY OF EVAPORATION: 50L/H ELECTRICAL HEATING, 3 PHASE 380V 50Hz EQUIPMENT CHARACTERISTICS AND METHODS 1. ATOMIZATION METHOD: HIGH-SPEED CENTRIFUGAL ATOMIZATION. 2. FEEDING SYSTEM: FEEDING PUMP FEEDS. (FREQUENCY) 3. RECEIVING METHOD: COLLECT FROM THE BOTTOM OF THE TOWER TO THE NEXT POINT OF THE CYCLONE SEPARATOR. 4. HEATING METHOD: ELECTRIC HEATING. 5. TOTAL EQUIPMENT POWER: 72KW Learn More
- A-2524 MELTBLOWN FABRIC PRODUCTION MACHINE 1600 mmA-2524 MELTBLOWN FABRIC PRODUCTION MACHINE 1600 mm MACHINE TYPE: MELTBLOWN WORKING WIDTH: 1600mm PRODUCTION SPEED: 24 TO 30 M/min EXTRUDER DIAMETER IN mm: 90mm EXTRUDER MOTOR IN KW: 45 KW PRODUCT WEIGHT RANGE: 8000 TO 1000 KGS MELTBLOWN FABRIC THICKNESS: 25 TO 30 GSM MAX OUTPUT: 1500 TO 1800 KG / 24 HOURS DIMENSION: 20000 X 8000 X 9000 mm WEIGHT: 8000 TO 1000 KGS POWER (TOTAL KW): 575 KW VOLTAGE: 220 VOLTS AND 50/60 Hz QUANTITY OF CONTAINERS NEEDED: 1 X 40 + 1 X 20 PRODUCTION TIME: 45 DAYS Learn More
- K-5045-A CONCRETE BATCHING CEMENT PLANTREFERENCE NUMBER: K-5045-A CONCRETE BATCHING CEMENT PLANT QUANTITY AVAILABLE: 1 Learn More
- TT-6933 SUCKER-MULLER-HACOBA SIZING MACHINE WITH DIRECT WARPER, WIDTH 4200mm, YEAR 2002TT-6933 SUCKER-MULLER-HACOBA SIZING MACHINE WITH DIRECT WARPER, WIDTH 4200mm, YEAR 2002 1. SIZING MACHINE BRAND SUCKER-MULLER-HACOBA 2. WIDTH 4200mm 3. YEAR: 2002 QUANTITY: 1 Learn More
- TT-6830 SIEMENS/RENTECH CONDENSING STEAM TURBINE-GENERATOR PACKAGE, 24.5MW, UNUSED, YEAR 2013 TO 2014, 50 HzTT-6830 SIEMENS/RENTECH CONDENSING STEAM TURBINE-GENERATOR PACKAGE, 24.5MW, UNUSED, YEAR 2013 TO 2014, 50 Hz ALREADY DISMANTLED THE PACKAGE AND CAN MAKE IT AVAILABLE FOR DELIVERY IN 2 WEEKS Learn More
- YY-2894 NEW SIEMENS SGT 400, YEAR 2018YY-2894 NEW SIEMENS SGT 400, YEAR 2018 SIEMENS SGT 400 (12.9 MW) GAS TURBINE · 11-STAGE COMPRESSOR, 6 COMBUSTION CHAMBERS, 2-STAGE POWER TURBINE · GAS FUEL SYSTEM · DLE COMBUSTION SYSTEM · HOT-END DRIVE · 2-SHAFT ENGINE · LEFT-HAND EXHAUST · MAIN LUBRICATION PUMP · EQUIVALENT OPERATING HOURS : 0H · TOTAL STARTS : 0 · NEW, NEVER INSTALLED OR COMMISSIONED QUANTITY: 1 Learn More
- C-3994 BARGEMOUNTED POWER PLANT, CAPACITY 220MW
C-3994 BARGEMOUNTED POWER PLANT, CAPACITY 220MW
A. ONCE THROUGH STEAM GENERATOR
B. BARGE
C. CHILLERS
D. AIR COMPRESSOR
E. GAS TURBINE
F. STEAM TURBINE
G. FEEDWATER SYSTEM
H. CLOSED COOLING WATER SYSTEM
I. AUXILIARY COOLING WATER SYSTEM
J. CONDENSATE POLISHING UNIT (CPU)
K. WASTE WATER SYSTEM
L. PLANT ELECTRICAL SYSTEM
M. BLACK START DG SET
N. PLANT CONTROLS AND INSTRUMENTATION
O. PLANT FIRE FIGHTING SYSTEM
P. START UP VACUUM SYSTEM
Q. STEAM TURBINE DEAERATING CONDENSERQUANTITY: 1 PLANT
Learn More - YY-2712-A GRAUFF AUTOMATIC FILLING-EQUIPMENTYY-2712-A GRAUFF AUTOMATIC FILLING-EQUIPMENT FILLING MACHINE WITH WEIGHING SYSTEM FOR EXAMPLE FOR PILLOW, COMPARTMENT CUSHION, FEATHER- AND DOWN BEDDING, COMFORTERS, ETC. - FOR THE CONNECTION TO THE FEEDING EQUIPMENT TYPES FZ. FOR EXACT DOSING AND FILLING OF DOWNS, FEATHERS, BLOW ABLE FIBERS, FIBER BALLS, FOAM-STICKS OR GRUMP AND MIXTURES. DOSING AND FILLING IS DONE IN SEPARATE STEPS. Learn More
- 1000 L STABILITY CHAMBERREFERENCE NUMBER: A-2492 1000 L STABILITY CHAMBER SPECIFICATIONS: INNER CHAMBER SIZE: 1 X 1 X 1 mm EXTERNAL DIMENSION: 1.2 X 1.97 X 2.17 mm TEMPERATURE RANGE: 70 TO 180°C HUMIDITY RANGE: 10% TO 98% RH, WHEN THE TEMPERATURE IS ABOVE 60°C, THE HUMIDITY CAN ACHIEVE 10% RH TEMPERATURE & HUMIDITY FLUCTUATION: ±0.2℃, ±0.5% RH INDICATION RESOLUTION: 0.01℃, 0.1% RH TEMPERATURE & HUMIDITY UNIFORMITY: ±2℃, ±3% RH (TESTED WITH THE EMPTY CHAMBER, 30 MINUTES AFTER STABILIZATION) HEAT UP AND COOL DOWN TIME: HEATING RATE: AVERAGE 3 ℃/MINUTES; COOLING RATE: AVERAGE 1 ℃/MINUTE (UNLOADED TEST) MATERIAL: INNER CHAMBER: SUS#304 STAINLESS STEEL EXTERIOR STRUCTURE: STAINLESS STEEL PLATE + POWDER COATED INSULATION: GLASS WOOL & PUF PERSPIRATION RESISTANT: K STYLE TUBE ACCESSORIES • TEMPERATURE RESISTANT SILICONE GASKET: 1 PC • CABLE PORT:1 PC; OD: 100 mm • WINDOW LIGHT: 1 PC • MULTIPANE VIEW WINDOW: 1 PC • LOADING SHELVES: 2 PCS REFRIGERATION & HEATING SYSTEM • ORIGINAL IMPORTED HIGH EFFICIENCY COMPRESSOR • AIR COOLING CONDENSER • FIN – TUBE HEATER • ORIGINAL IMPORTED SOLENOID VALVES • INNER SPIRAL K – TYPE REFRIGERANT COPPER TUBE • U – TYPE FINNED ELECTRO - THERMAL TUBE • HEATING & COOLING SYSTEMS SEPARATED • SINGLE STAGE REFRIGERATING SYSTEM HUMIDIFYING & DEHUMIDIFYING SYSTEM • ELECTRIC & BYTE TYPE HUMIDIFYING SYSTEM • STAINLESS STEEL HUMIDIFYING BARREL WITH VIEW WINDOW FOR WATER LEVEL • ADP DEHUMIDIFYING WAY • OVER – TEMPERATURE AND OVERFLOW PROTECTION UNITS • HUMIDIFYING & DEHUMIDIFYING SYSTEMS SEPARATED CIRCLING & DRAIN SYSTEM • CENTRIFUGAL FAN & IMPORTED MOTOR • REVERSE UNIFLOW (AIR FLOW DIRECTION) • FLOW – THROWS WIND • DRAIN SYSTEM USES SWIRL TYPE OUTLET AND U – TRAP DEPOSITION UNIT PROGRAMABLE MICRO COMPUTER LCD TOUCH CONTROLLER • PROGRAMMABLE TOUCH CONTROLLER, USER - FRIENDLY, STABLE AND EASY USE • PROGRAMS: 99 SEGMENTS PER PROGRAM, 120 PROGRAMS, 120 CYCLING PER PROGRAM • PID & SSR CONTROL WAY, STABLE AND EASY USE • HAVE SLOP CONTROL FUNCTION FOR HEATING & COOLING, LINKED PTNS CAN BE EXECUTED • PID AUTOMATIC CALCULATION • MICRO COMPUTER MULTI FUNCTION CONTROLLER, MAIN COMPONENTS ’DATA AUTOMATICALLY OUTPUT INCLUDING COMPRESSORS, SOLENOIDS, HEATING UNITS, ETC • ERRORS OF MAIN COMPONENTS APPEAR ON THE LCD PANEL • THE BRIGHTNESS OF THE LCD PANEL CAN BE ADJUSTED • TIME SEQUENCE CONTROL INTERFACE RELAYS HAVE 3 GROUPS WHICH MANAGE THE OUTPUT OF OUTSIDE LOGIC UNITS INCLUDING SIGNAL, MECHANICAL AND POWER, ETC • PROGRAMS AUTO – SAVE FUNCTION IF POWER CUT OFF SUDDENLY • HAVE HOLD & ADV BUTTONS INPROGRAMS • AUTOMATICALLY SET THE HIGH & LOW TEMPERATURE LIMITS AFTER PROGRAMS SET • PASSWORD SET FUNCTION • SD CARD SLOT, 2 GB SD CARD, RS232 OR ETHERNET (RJ45) OPERATING ENVIRONMENT • AMBIENT TEMPERATURE: +25℃ (2) RH ≤85% PROTECTION • ELECTRICITY LEAK PROTECTION • LIGHTNING STRIKE PROTECTION, ZRN LIGHTNING ARRESTER INSIDE THE CONTROLLER • SENSOR DATES TRANSFERRED INSIDE THE MICRO COMPUTER • TEMP. SENSORS TO OPEN CIRCUIT OR SHORT CIRCUIT (+ - OVER) • THE FIRST LEVEL OVER TEMPERATURE PROTECTION • ERROR DETECTED UNITS • THE SECOND LEVEL OVER TEMPERATURE PROTECTION TO ELECTRONIC OVER - TEMP PROTECTION UNIT • THE THIRD LEVEL OVER - TEMPERATURE PROTECTION • COMPRESSOR PROTECTION TO REFRIGERANTS PRESSURE PROTECTION & OVERLOAD PROTECTION. • EXTENDED PROTECTION UNIT TO TWO SUPPLETIVE PORTS • ERROR PROTECTION TO POWER CUT OFF, ERROR REPORTS SHOWN IN LCD PANEL AND AUDIBLE ALARM STARTS • DYNAMIC HIGH AND LOW TEMPERATURE PROTECTION • AMBIENT TEMPERATURE PROTECTION TO THE INNER CHAMBER AND SPECIMENS AUTOMATICALLY RETURN BACK TO AMBIENT TEMPERATURE AFTER THE OPERATION STOP SAFETY PROTECTION • NON-FUSE PROTECTION SWITCH • OVERHEAT ALARM PROTECTION • COMPRESSOR OVERLOAD PROTECTION • PHASE SEQUENCE PROTECTION • MOTOR OVER TO CURRENT PROTECTION Learn More
- P-4421 LAUNDRY SOAP PRODUCTION LINECAPACITY 1000 to 1500 KILOGRAMS PER HOUR
REFERENCE NUMBER: P-4421
VOLUME: 10m3SIZE:φ2800 x 3000, 20 m3POWER: 5.5 KILOWATTS PER SETLearn More