Search results for: 'generator 60 k'
- Related search terms
- Generator
- generators
- generator set
- generator 3.8
- Generator power
-
TT-2227 TRANSPORT TRAILERS, 10 X 60 TON PLUS TRUCK TRACTORS, 10 X 8 X 8 FOR TOWING THESE TRAILERS, ALMOST NEW, ONLY 500 MILESTT-2227 TRANSPORT TRAILERS, 10 X 60 TON PLUS TRUCK TRACTORS, 10 X 8 X 8 FOR TOWING THESE TRAILERS, ALMOST NEW, ONLY 500 MILES TOTAL QUANTITY: 20 Learn More -
AA-1175 AUTOMATIC KN95 MASK MACHINE LINE DUCK BILL TYPEAA-1175 AUTOMATIC KN95 MASK MACHINE LINE DUCK BILL TYPE MACHINE PARAMETERS: DIMENSIONS: - FILM MACHINE x 1 SET: 1450 x 920 x 1350mm - EAR STRAP MACHINE x 3 SETS: 850 x 550 x 1400mm x 3 - BANDING MACHINE x 2 SETS: 980 x 430 x 1100mm x 2 - FEEDING MATERIAL FRAME x 1 SET: 3500 x 2050 x 950mm TOTAL VOLUME WEIGHT: 2128 TO 2300T Learn More -
T-6546 PFE TESTER FOR PELLET FILTRATION EFFICIENCY OF SURGICAL MASKREFERENCE NUMBER: T-6546PFE TESTER FOR PELLET FILTRATION EFFICIENCY OF SURGICAL MASKINTRODUCTIONMEDICAL SURGICAL MASK PARTICLE FILTRATION EFFICIENCY PFE TESTER IS SUITABLE FOR MEDICAL INSTRUMENT INSPECTION CENTER, SAFETY PROTECTION INSPECTION CENTER, LABOR PROTECTION INSPECTION CENTER, DRUG INSPECTION CENTER, DISEASE PREVENTION AND CONTROL CENTER, TEXTILE INSPECTION CENTER, HOSPITAL, MASK AND RESPIRATOR MANUFACTURERS, ETC.FEATURESTHE PFE TESTER FOR PARTICLE FILTRATION EFFICIENCY OF SURGICAL MASKS IS EQUIPPED WITH A SPECIAL SALT AEROSOL GENERATOR, WHICH CAN PRODUCE AEROSOLS WITH SPECIFIC PARTICLE SIZE AND CONCENTRATION.EQUIPPED WITH A SERIES OF SPECIAL FIXTURE, SUITABLE FOR THE DETECTION OF ALL KINDS OF MASKS.BUILT-IN HIGH LIFE PHOTOMETER MODULE, SAMPLING TIME ACCUMULATION, PROMPT LIGHT CLEANING.AUTOMATIC CONTROL OF AEROSOL GENERATION, AUTOMATIC CALCULATION OF CAPTURE EFFICIENCY AND MASK AIRFLOW RESISTANCE, REDUCE HUMAN INTERVENTION.BUILT-IN HIGH PRECISION ELECTRONIC FLOWMETER AND HIGH PERFORMANCE SAMPLING PUMP TO ENSURE FLOW STABILITY.PARAMETERTEST FLOW: PARAMETER RANGE: (5 ~ 100) L/MIN; RESOLUTION: (5 ~ 100) L/MIN;MAXIMUM ALLOWABLE ERROR: ±1%PRESSURE DETECTION RANGE: PARAMETER RANGE: (0 ~ 2500) PA; RESOLUTION: 0.1PA; MAXIMUM ALLOWABLE ERROR: ±1%CONCENTRATION DETECTION RANGE: PARAMETER RANGE: (0.001 ~ 100) 0 G/L;DETECTION ACCURACY: 1% OF THE READ VALUE IN THE RANGE OF 0.01% TO 100%DETECTION REPEATABILITY: 5% OF THE READ VALUE IN THE RANGE OF 0.01% TO 100% MEDIAN DIAMETER OF SALT AEROSOL PARTICLES (CMD): (0.075±0.02)MMEDIAN AEROSOL PARTICLE NUMBER DIAMETER (CMD) (OPTIONAL): (0.185±0.02) MOPERATING TEMPERATURE: 20±5CLearn MoreINSTRUMENT NOISE: <60DB(A)POWER SUPPLY: AC220V±10%, 50HZMAIN MACHINE SIZE: (LENGTH 700 X WIDTH 720 X HEIGHT 1450) mmQUANTITY: 1 -
L-5951 WESTINGHOUSE 100 MW GAS TURBINES, LNG FIRED, 60 Hz, YEAR 1995REFERENCE NUMBER: L-5951
WESTINGHOUSE 100 MW GAS TURBINES, LNG FIRED, 60 Hz, YEAR 1995
GAS TURBINES
MAKE: WESTINGHOUSE
YEAR: 1995 (STOPPED IN JUNE 2013)
100 MW EACH X 6 = 600 MW TOTAL
QUANTITY: 5
Learn More -
M-7677 HIGH SPEED ALUMINUM NESPRESSO FILLING SEALING MACHINEREFERENCE NUMBER: M-7677
Learn More
HIGH SPEED ALUMINUM NESPRESSO FILLING SEALING MACHINE
TECHNICAL PARAMETERS:
MODEL #1:
SPEED: 8,500 TO 9,600 CUPS PER HOUR
WORKING STATION: 4 LANES
MACHINE SIZE (LxWxH): 5000mm x 1000mm x 2600mm
MODEL #2:
SPEED: 4,000 TO 4,800 CUPS PER HOUR
WORKING STATION: 2 LANES
MACHINE SIZE (LxWxH): 5000mm x 900mm x 2600mm -
L-1193 WARTSILA 1.48 MW MODEL 9L20 HFO GENERATORL-1193 WARTSILA 1.48 MW MODEL 9L20 HFO GENERATOR
MODEL: W9L-20
YEAR: 05/2004
DATE OF COMMISSIONING: 08/09/2004
CAPACITY: 1548 KW
SPEED: 1000 RPM
NO. OF RUNNING HOURS: 41733HRS
INSTALLATION TYPE: STATIONARY ENGINE
FITTED WITH SINGLE BASE FRAME LOADED ON SPRING
ENGINE MOUNTED PHE & CHARGER AIR COOLER.ALTERNATOR DETAILS:
MAKE: AVK
TYPE: DIG 130K/6
CAPACITY :1852 KVA
SELF EXCITED WITH ROTATING BRIDGEDIODESBOOSTER AND FEEDER UNIT:
MAKE: WARTSILA INDIA LTDLUBE OIL SEPARATOR:
MAKE: ALFA LAVAL
MODEL: MMPX 403 SGP-11HFO SEPARATOR:
MAKE: ALFA LAVAL
MODEL: PA-6001) HFO STORAGE TANK
CAPACITY :100 KL2) HFO DAY TANK
CAPACITY :50 KL3) SLUDGE TANK
CAPACITY :10 KL
CHARGE AIR FILTER:
MAKE: AAFRADIATOR:
MAKE: COIL COMPANY
MODEL: FCW220
RETURN FUEL UNIT:
MAKE: WARTSILA INDIA LIMITEDENGINE CONTROL PANEL:
1) ENGINE CONTROL PANEL(CFC_011)
2) BATTERY CHARGER UNIT
MAKE: AMARARAJA
RATING :100AH
PCC PANELSTARTING AIR COMPRESSOR:
MAKE: INGERSOLL RAND
MODEL :7T2INCOMING & OUT GOING BREAKER:
MAKE: ABB
TYPE: SF6QUANTITY: 1
Learn More -
M-6092 ETHYLENE OXIDE STERILIZERREFERENCE NUMBER: M-6092
ETHYLENE OXIDE STERILIZERSTERILIZING TEMPERATURE: 0~100°C, PID ADJUSTABLE
Learn More
STERILIZING PRESSURE: -95~+80KPA
STERILIZING HUMIDITY: 20~100% RH, ADJUSTABLE
EO CONCENTRATION: 300~1,000 MG/L
STERILIZING TIME: 3~12 HRS -
C-3990 HYUNDAI HIMSEN 9H25/33 HFO POWER PLANT, CAPACITY 10.5 MW, YEAR 2014 - NEWC-3990 HYUNDAI HIMSEN 9H25/33 HFO POWER PLANT, CAPACITY 10.5 MW, YEAR 2014 - NEW
MAKE/MODEL: HYUNDAI HIMSEN 9H25/33
HFO POWER PLANT
CAPACITY: 10.5 MW
WATTAGE: 46,200 KW
YEAR: 2014
HOURS: NEW
FUEL TYPE: HFO
FREQUENCY: 50 HZ
ENCLOSURE: SOUND ATTENUATED ENCLOSURE
MANUFACTURER: HHI
ENGINE MODEL: HYUNDAI HIMSEN 9H25/33
GENERATOR MODEL: HYUNDAI
FOR 50HZ: 2100KW, 6000V, 750 RPMQUANTITY: 5
Learn More -
M-4835 POWER AND INDUSTRIAL PLANTS FOR SALEREFERENCE NUMBER: M-4835 (1111VEHJXX10) L POWER AND INDUSTRIAL PLANTS FOR SALE QTY. OUTPUT (MW) DESCRIPTION MANUFACTURER/ TYPE BUILT/ CONDITION 1 230 COMBINED CYCLE GAS TURBINE POWER PLANT SIEMENS V94-2 1988 1 220 COMBINED CYCLE POWER PLANT 50 HZ, FUEL: DUAL FUEL (NATURAL GAS OR HFO/DIESEL) GE FRAME 6B CCPP 1992, RUNNING HOURS: 135 000, PREUSED 1 180 GAS TURBINE 125 MW, STEAM TURBINE 55 MW, 50 HZ, FUEL LFO AND NG GE FRAME 9E CCPP 2005, RUNNING HOURS: 2000 2 128 COMPLETE POWER PLANTS, 15 KV, FUEL: NATURAL GAS AND LIGHT OIL GE FRAME PG9171E NEW 2 127 GAS TURBINE PACKAGES FIAT AVIO MODEL TG 50 – D5 1998,DISMANTLED, OVERHAULED, UPGRADED FROM SIEMENS AND DISMANTLED 2 125 COMPLETE PLANT, 2 UNITS ABB GAS TURBINE PACKAGES, FUEL: DUAL FUEL, 50 HZ ABB, 50WT 18H-66 1995, JUST OVERHAULED, WARRANTY POSSIBLE 1 93 COMBINED CYCLE POWER PLANT. FUEL : NATURAL GAS GE FRAME 6FA 1997 MAJOR INSPECTION IN 2009 1 73 COMBINED CYCLE POWER PLANT. FUEL: NATURAL GAS. 50 HZ. SIEMENS WESTINGHOUSE AND MITSUBISHI. 1999, RUNNING HOURS 97 000 1 70 COMBINED CYCLE POWER PLANT THOMASSEN/ABB 2009, RUNNING HOURS UNDER 90 000 CONDITION GOOD, 2009 OVERHAULED 5 66 GAS TURBINE PACKAGES, 50 OR 60 HZ ROLLS ROYCE, TRENT 60 2014, RUNNING HOURS ZERO 3 49 GAS TURBINE POWER PLANT, 50 HZ 3 UNITS GE LM 6000 PC 2004, RUNNING HOURS 6000 QTY. OUTPUT (MW) DESCRIPTION MANUFACTURER/ TYPE BUILT/ CONDITION 1 46 COMPLETE PLANT, INCLUDES 5 GAS TURBINE PACKAGES, INCLUDING 1 STEAM TURBINE, BOILER AND AUXILIARIES. FUEL: NATURAL GAS AND NAPHTA. 50 HZ. SIEMENS TYPHOON AND ALSTOM. 2000, LOW HOURS, STILL IN OPERATION 1 42 COMBINED CYCLE POWER PLANT. FUEL: NATURAL GAS. 50 HZ. GE LM 6000PA 1997, LAST HOT END OVERHAUL WAS AT 86.080 HOURS IN AUG 2010 1 41 GAS TURBINE PACKAGE WITH HRSG, 50HZ FUEL: NATURAL GAS/FUEL OIL THOMASSEN PG-6541 1995, LAST OVERHAUL AT 118350 1 40 COMBINED CYCLE POWER PLANT. FUEL: NATURAL GAS AND LIGHT OIL. 50 HZ. GE FRAME 6 B, DRY LOW NOX 1992, RECENTLY OVERHAULED, STILL GOOD FOR MORE THAN 24.000 RUNNING HOURS. READY TO SHIP. 5 37 GAS TURBINE PACKAGES, DUAL FUEL, 50/60 HZ SGT 750 SIEMENS NEW, ZERO HOURS 1 31,2 GAS TURBINE PACKAGES, 31,2 MW , 50/60 HZ, SGT 700 NEW, ZERO HOURS 5 31 GAS TURBINE PACKAGES, DUAL FUEL, 50/60 HZ GE TM2500 NEW 1 29,65 GAS TURBINE GENERATOR, 50 HZ, 11 KV SGT 700 2011, RUNNING HOURS ZERO (NEW) 1 27 COMBINED CYLE POWER PLANT, 27 MW, NATURAL GAS GE RLM 2500 PE AND ALSTOM STEAM TURBINE GAS TURBINE 1994, STEAM TURBINE 1996 1 26,59 GAS TURBINE, FUEL: GAS FRAME 5, PG-5371 PA 1995, RUNNING HOURS 174,104 4 24,6 CORE ENGINE FUEL: NATURAL GAS, 50 HZ SIEMENS SGT 600 (EX ABB GT 10B) 1994-1997, ZERO HOUR OVERHAULED 1 16 GAS TURBINE PACKAGE DUEAL FUEL ROLLS ROYCE AVON 1534-102L ZERO HOUR OVERHAULED IN 2008 1 14,25 NATURAL GAS ENGINE SOLAR TITAN 130 SOLONOX, 50 HZ TURBOMACH T19501 2007, ZERO RUNNING HOURS, AS NEW 3 12,9 GAS TURBINES SIEMENS, 60 HZ SIEMENS SGT 400 2014, NEW NEVER USED 1 11,86 GAS TURBINE, 60 HZ SOLAR MARS 100 15000 SOLONOX 1996, RUNNING HOURS 34 000 SINCE LAST OVERHAUL 2 9,2 CHP PLANT ELECTRIC, NATURAL GAS AND LIGHT DIESEL&BOTH SOLAR CENTAUR 50 T5701 2005 AND 2008, RUNNING HOURS 26 000 AND 2 500 1 8,8 COMBINED CYCLE GAS TURBINE POWER PLANT. 60 HZ. SOLAR MARS 90. 1989, LAST MAJOR OVERHAUL IN 2004, ONLY 1225 RUNNING HOURS 1 7,5 NATURAL GAS ENGINE SOLAR TAURUS T70, 50 HZ TURBOMACH SOLONOX + WHRB 2007, ZERO RUNNING HOURS AS NEW 1 5,5 GAS TURBINE, 50 HZ, NATURAL GAS SGT 200 1989, RUNNING HOURS 126 340 QTY. OUTPUT (MW) DESCRIPTION MANUFACTURER/ TYPE BUILT/ CONDITION 1 5,2 DUAL NATURAL GAS AND OIL ENGINE TAURUS 60, 50 HZ SOLAR TAURUS 60, SOLONOX T7301 1998, RUNNING HOURS17 700 1 1,4 GAS TURBINE PACKAGE INCL. HRSG, 50 HZ KAWASAKI KA 1334 1995, RUNNING HOURS AFTER MAJOR OVERHAUL 4000 Learn More